background image

WARNING

This product must be disconnected from the circuit if subjected to any high voltage or insulation resistance 
testing. Irreparable damage will occur if this instruction is not followed.

GENERAL

This product contains a light source of energy efficiency class C (TRLED14EM, TRLED25EMD, TRLED26EMD) 
/ D (TRLED15EM, TRLED15EMD, TRLED16EM, TRLED16EMD, TRLED24EM, TRLED25EM, TRLED26EM) to 
Regulation (EU) No. 2019/2015.
This product contains a non-replaceable LED light source and a control gear which can be replaced by a 
professional.

Clean the external surfaces with a damp cloth using a mild solution of detergent and warm water only, do not 
use aggressive cleaning products or solvents which may damage the product.  
Do not use any source of high-pressure washers to maintain or clean this luminaire.
This product is non-dimmable.
This product should be dismantled for disposal when it reaches the end of its life. Please see website for 
dismantling instructions.
This product should be recycled in the correct manner when it reaches the end of its life. Check local authorities 
for where facilities exist. 
The batteries in this luminaire are Nickel Cadmium and must be disposed of correctly. Please contact the local 
authorities for the disposal of this toxic waste. 

Summary of Contents for TRLED14EM

Page 1: ...INSTALLATION MAINTENANCE MANUAL TRLED14EM TRLED15EM TRLED15EMD TRLED16EM TRLED16EMD TRLED24EM TRLED25EM TRLED25EMD TRLED26EM TRLED26EMD...

Page 2: ...n this luminaire is fitted does not exceed the rating of the circuit cable fuse or circuit breaker Please note the IP Ingress Protection rating of this product when deciding the location for installat...

Page 3: ...s are shown in Fig 1 Fig 1 Secure the mounting brackets to the surface using suitable fixings not included Unfasten the clips on either side of the fitting see Fig 2 Fig 2 Remove the gear tray from th...

Page 4: ...attery pack to the emergency inverter via the plug and socket Align the fitting with the mounting brackets and clip into place Tighten the compression gland ensuring a tight seal is made Replace the g...

Page 5: ...n the external surfaces with a damp cloth using a mild solution of detergent and warm water only do not use aggressive cleaning products or solvents which may damage the product Do not use any source...

Page 6: ...ge indicator is illuminated If the luminaire fails any of the above tests please contact a qualified electrician See below for test record sheet WARRANTY This product has a warranty of 5 years excludi...

Page 7: ...R THIRD YEAR FOURTH YEAR FIFTH YEAR SIGNED DATE SIGNED DATE SIGNED DATE SIGNED DATE SIGNED DATE 1 FUNCTIONAL 2 FUNCTIONAL 3 FUNCTIONAL 4 FUNCTIONAL 5 FUNCTIONAL 6 FUNCTIONAL 7 FUNCTIONAL 8 FUNCTIONAL...

Page 8: ...DCSEP21_V2 ML Accessories Limited LU5 4LT www mlaccessories co uk 52 INTERNATIONAL CONTACT DETAILS INTERNAT CONTACT D 20 35 C TA...

Reviews: