INSTALLATION & MAINTENANCE MANUAL
These instructions should be read carefully and retained after installation by the end user for future reference
and maintenance.
These instructions should be used to aid installation of the following products:
TRLED151 / TRLED221
SAFETY
•
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
•
Please isolate mains prior to installation or maintenance
•
Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of
the circuit cable, fuse or circuit breaker
•
Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
•
This product is Class I and must be earthed
•
This product is IP65 rated
INSTALLATION
Note - If this product is being used in conjunction with an external PIR or sensor, please confirm with the
manufacturer of the sensors that they are compatible with LED luminaires.
•
Provide power to the required point of installation (refer to BS7671 for correct cabling methods).
Suitable IP rated junction boxes should be used where required
•
Using the mounting brackets as a template, mark the location for, and drill the fixing holes ensuring not
to infringe with any gas/water pipes or electrical cables. Fixing centres are shown in Fig. 1
Fig. 1
•
Secure the mounting brackets to the surface using suitable fixings (not included)
•
Unfasten the clips on either side of the fitting (see Fig. 2)
Fig. 2
•
Remove the gear tray from the baseplate by pinching the clips at two locations (see Fig. 3)
Fig. 1
Fig. 2
• Secure the mounting brackets to the surface using suitable fixings (not included)
• Unfasten the clips on either side of the fitting (see Fig. 2)
INSTALLATION & MAINTENANCE MANUAL
These instructions should be read carefully and retained after installation by the end user for future reference
and maintenance.
These instructions should be used to aid installation of the following products:
TRLED14EM / TRLED15EM / TRLED15EMD / TRLED16EM / TRLED16EMD / TRLED24EM / TRLED25EM /
TRLED25EMD / TRLED26EM / TRLED26EMD
SAFETY
•
This product must be installed in accordance with the latest edition of the IEE Wiring Regulations
(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician
•
Please isolate mains prior to installation or maintenance
•
Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of
the circuit cable, fuse or circuit breaker
•
Please note the IP (Ingress Protection) rating of this product when deciding the location for installation
•
This product is Class I and must be earthed
•
This product is IP65 rated
INSTALLATION
Note - If this product is being used in conjunction with an external PIR or sensor, please confirm with the
manufacturer of the sensors that they are compatible with LED luminaires.
•
Provide power to the required point of installation (refer to BS7671 for correct cabling methods).
Suitable IP rated junction boxes should be used where required
•
Using the mounting brackets as a template, mark the location for, and drill the fixing holes ensuring not
to infringe with any gas/water pipes or electrical cables. Fixing centres are shown in Fig. 1
Fig. 1
•
Secure the mounting brackets to the surface using suitable fixings (not included)
•
Unfasten the clips on either side of the fitting (see Fig. 2)