background image

INSTALLATION & MAINTENANCE MANUAL 

These instructions should be read carefully and retained after installation by the end user for future reference 

and maintenance. 

These instructions should be used to aid installation of the following products: 

TRLED151 / TRLED221 
SAFETY 

 

This product must be installed in accordance with the latest edition of the IEE Wiring Regulations 

(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician 

 

Please isolate mains prior to installation or maintenance 

 

Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of 

the circuit cable, fuse or circuit breaker 

 

Please note the IP (Ingress Protection) rating of this product when deciding the location for installation 

 

This product is Class I and must be earthed 

 

This product is IP65 rated  

INSTALLATION 

Note - If this product is being used in conjunction with an external PIR or sensor, please confirm with the 

manufacturer of the sensors that they are compatible with LED luminaires. 

 

Provide power to the required point of installation (refer to BS7671 for correct cabling methods). 

Suitable IP rated junction boxes should be used where required 

 

Using the mounting brackets as a template, mark the location for, and drill the fixing holes ensuring not 

to infringe with any gas/water pipes or electrical cables. Fixing centres are shown in Fig. 1

 

 

 

 

Fig. 1 

 

Secure the mounting brackets to the surface using suitable fixings (not included)  

 

Unfasten the clips on either side of the fitting (see Fig. 2) 

 

 

Fig. 2 

 

Remove the gear tray from the baseplate by pinching the clips at two locations (see Fig. 3) 

Fig. 1

Fig. 2

• Secure the mounting brackets to the surface using suitable fixings (not included) 
• Unfasten the clips on either side of the fitting (see Fig. 2)

INSTALLATION & MAINTENANCE MANUAL 

These instructions should be read carefully and retained after installation by the end user for future reference 

and maintenance. 

These instructions should be used to aid installation of the following products: 

TRLED14EM / TRLED15EM / TRLED15EMD / TRLED16EM / TRLED16EMD / TRLED24EM / TRLED25EM / 

TRLED25EMD / TRLED26EM / TRLED26EMD 
SAFETY 

 

This product must be installed in accordance with the latest edition of the IEE Wiring Regulations 

(BS7671) and current Building Regulations. If in any doubt, consult a qualified electrician 

 

Please isolate mains prior to installation or maintenance 

 

Check the total load on the circuit (including when this luminaire is fitted) does not exceed the rating of 

the circuit cable, fuse or circuit breaker 

 

Please note the IP (Ingress Protection) rating of this product when deciding the location for installation 

 

This product is Class I and must be earthed 

 

This product is IP65 rated  

INSTALLATION 

Note - If this product is being used in conjunction with an external PIR or sensor, please confirm with the 

manufacturer of the sensors that they are compatible with LED luminaires. 

 

Provide power to the required point of installation (refer to BS7671 for correct cabling methods). 

Suitable IP rated junction boxes should be used where required 

 

Using the mounting brackets as a template, mark the location for, and drill the fixing holes ensuring not 

to infringe with any gas/water pipes or electrical cables. Fixing centres are shown in Fig. 1

 

 

 

 

Fig. 1 

 

Secure the mounting brackets to the surface using suitable fixings (not included)  

 

Unfasten the clips on either side of the fitting (see Fig. 2) 

 

Summary of Contents for TRLED14EM

Page 1: ...INSTALLATION MAINTENANCE MANUAL TRLED14EM TRLED15EM TRLED15EMD TRLED16EM TRLED16EMD TRLED24EM TRLED25EM TRLED25EMD TRLED26EM TRLED26EMD...

Page 2: ...n this luminaire is fitted does not exceed the rating of the circuit cable fuse or circuit breaker Please note the IP Ingress Protection rating of this product when deciding the location for installat...

Page 3: ...s are shown in Fig 1 Fig 1 Secure the mounting brackets to the surface using suitable fixings not included Unfasten the clips on either side of the fitting see Fig 2 Fig 2 Remove the gear tray from th...

Page 4: ...attery pack to the emergency inverter via the plug and socket Align the fitting with the mounting brackets and clip into place Tighten the compression gland ensuring a tight seal is made Replace the g...

Page 5: ...n the external surfaces with a damp cloth using a mild solution of detergent and warm water only do not use aggressive cleaning products or solvents which may damage the product Do not use any source...

Page 6: ...ge indicator is illuminated If the luminaire fails any of the above tests please contact a qualified electrician See below for test record sheet WARRANTY This product has a warranty of 5 years excludi...

Page 7: ...R THIRD YEAR FOURTH YEAR FIFTH YEAR SIGNED DATE SIGNED DATE SIGNED DATE SIGNED DATE SIGNED DATE 1 FUNCTIONAL 2 FUNCTIONAL 3 FUNCTIONAL 4 FUNCTIONAL 5 FUNCTIONAL 6 FUNCTIONAL 7 FUNCTIONAL 8 FUNCTIONAL...

Page 8: ...DCSEP21_V2 ML Accessories Limited LU5 4LT www mlaccessories co uk 52 INTERNATIONAL CONTACT DETAILS INTERNAT CONTACT D 20 35 C TA...