WARNING
This product must be disconnected from the circuit if subjected to any high voltage or
insulation resistance testing. Irreparable damage will occur if this instruction is not followed.
This product is not suitable for direct installation in the ground, nor in a retaining wall where
the ground behind may become saturated.
This product is not suitable for installation in or near a coastal or marine environment.
• Connect the luminaire to the mains supply ensuring the correct polarity is observed:
L – Live (brown), E – Earth (green/yellow), N – Neutral (blue). Oversleeving is provided to
help protect the incoming mains cable. The cable and terminal block should be kept away
from the lamp to prevent heat damage
• Insert a suitable E27 lamp (not included), max. 40W
• Refasten the glass (frosted side in) and chosen fascia ensuring the gasket is in place and
a tight seal is made
• Switch on and check for correct operation
• Should the protective glass be cracked or damaged it should be replaced immediately
• This fitting must not be used without the protective glass installed