background image

These instructions should be read carefully and retained after installation by the end user for 
future reference and maintenance. 
These instructions should be used to aid installation of the following products: 
24DC100M / 24DC150M  / 24DC200M 

GENERAL INSTRUCTIONS

• This product must be installed in accordance with the latest edition of the IEE Wiring Regulations (BS7671) 

and current Building Regulations. If in any doubt, consult a qualified electrician 

• Please isolate mains prior to installation or maintenance 
• Check the total load on the circuit (including when this product is fitted) does not exceed the rating of the 

circuit cable, fuse, or circuit breaker 

• Please note the IP (Ingress Protection) rating of this product when deciding the location for installation 
• Allow 50mm above and around the fitting for air dissipation (do not cover the fitting with insulation) 
• Do not overload this accessory or subject it to conditions outside its rating 
• This product is for indoor use only 
• This product must be placed inside a suitable enclosure 
• This product is Class I and must be earthed 
• This product is IP20 rated 

SAFETY

INSTALLATION

• Provide power to the required point of installation  
• Mount the driver in a suitable vented enclosure ensuring there is adequate space around and above the 

product for heat dissipation 

• Connect to the mains supply ensuring the correct polarity is observed (see Fig. 1): L – Live (brown), 

E – Earth (green/yellow), N – Neutral (blue) 