Operation
Elite
TM
37
Supported
OLC
Commands
(User
Level)
Command
Parameters
Description
K
Access
Level
Key
code
Enables
access
to
advanced
generator
controls.
Only
used
by
MKS
Trained
Field
Service
and
Applications
personnel
E
RS
‐
232
Enable
None
Enables
RS
‐
232
control
of
the
generator
I
RS
‐
232
Disable
None
Disables
control
of
the
generator
through
the
RS
‐
232
port.
Even
when
control
is
disabled,
readbacks
can
still
be
obtained
via
this
interface.
N
RF
ON
None
Enables
RF
Output
F
RF
OFF
None
Disables
RF
Output
A
Forward
Power
Leveling
None
Sets
the
controller
leveling
mode
to
forward
leveling.
In
this
mode,
forward
power
will
match
the
setpoint,
except
when
the
generator
exceeds
the
reverse
power
limit.
V
Delivered
Power
Leveling
None
Sets
the
controller
leveling
mode
to
delivered
leveling.
In
this
mode,
the
load
power
(forward
–
reflected)
will
match
the
setpoing,
except
when
the
generator
exceeds
the
reverse
power
or
forward
power
limits.
G
External
Power
Leveling
None
Future
use
–
sets
the
controller
leveling
mode
to
external
leveling.
In
this
mode,
an
external
readback
signal
(i.e.
DC
bias)
sets
the
level
the
generator
will
attempt
to
achieve.
P
Power
Setpoint
XXXXXX
Sets
the
power
setpoint
for
the
generator.
After
the
‘P’
command
is
issued,
the
generator
will
respond
with
“Enter
New
Setpoint
(AAAAAA
‐
BBBBBB):”.
The
power
setpoint
must
be
entered
as
a
six
digit
value
(i.e.
000750
for
750W.
Note
‐
the
leading
zeros
are
required)
C
CEX
Enable
None
Activates
CEX
mode.
In
this
mode,
the
generator
receives
its
drive
signal
from
the
source
attached
to
CEX
IN.
Please
review
the
specifications
section
for
CEX
signal
requirements.
J
CEX
Disable
None
Disables
CEX
mode.
When
disabled,
the
generator
uses
its
internal
13.56MHz
source.
Q
Set
Pulse
High
Time
XXXXXX
When
utilizing
pulse
mode,
this
command
sets
the
pulse
high
time
in
microseconds.
After
the
‘Q’
command
is
issued,
the
generator
will
respond
with
“High
Pulse
Time:”.
The
pulse
high
time
must
be
entered
as
a
six
digit
value
(i.e.
005000
for
5000us.
Note
‐
the
leading
zeros
are
required).
X
Set
Pulse
Low
Time
XXXXXX
When
utilizing
pulse
mode,
this
command
sets
the
pulse
low
time
in
microseconds.
After
the
‘X’
command
is
issued,
the
generator
will
respond
with
“Low
Pulse
Time:”.
The
pulse
low
time
must
be
entered
as
a
six
digit
value
(i.e.
005000
for
5000us.
Note
‐
the
leading
zeros
are
required)
U
Enable
Pulsing
None
Enables
internal
pulsing
of
the
RF
output.
Y
Disable
Pulsing
None
Disables
internal
pulsing
and
allows
CW
operation
of
the
generator.