System
Installation
elite
TM
29
Status
LEDs
All
versions
of
the
elite
TM
generator
utilize
two
LEDs
on
the
rear
panel
to
provide
information
on
the
generator
status
as
well
as
any
faults
or
warnings.
Under
normal
operating
conditions,
the
PWR
and
STAT
LEDs
will
be
solid
or
flash
green.
Under
fault
or
warning
conditions,
these
LEDs
will
turn
amber
or
red
and
flash
in
a
pattern
indicating
what
fault
is
active.
In
the
case
of
multiple
faults
or
warnings,
there
will
be
a
one
second
OFF
period
between
codes.
Status
PWR
LED
STAT
LED
AC
ON
Solid
Green
‐‐‐‐‐
System
Ready
Solid
Green
Solid
Green
RF
On
Flashing
Green
(2Hz)
‐‐‐‐‐
RF
within
regulation
Flashing
Green
(2Hz)
Flashing
Green
(2Hz)
Interlock
fault
Solid
Amber
‐‐‐‐‐‐
Warning
Flashing
Amber
(see
below)
Fault
Solid
Red
Flashing
Red
(see
below)
Fault
Codes
Fault
RED
STAT
LED
flash
pattern
(250ms
between
flashes)
Overheat
Fault
ON
‐
OFF
VIF
Link
Integrity
Fault
ON
‐
OFF
‐
ON
‐
OFF
Profibus
Master
lost
with
RF
ON
ON
‐
OFF
‐
ON
‐
OFF
‐
ON
‐
OFF
Profibus
Link
Integrity
ON
‐
OFF
‐
ON
‐
OFF
‐
ON
‐
OFF
‐
ON
‐
OFF