background image

 

 File: FR/CR840_r3 - April 2017 - Technical note: FR/CR                                                                        

                                page   3  of   16

             

FR 840 & CR 840

Contents

C

CE Declaration  1
Cleaning  8

E

Environmental & Physical characteristics  6
Equipment installation  8
Equipment maintenance  8
Equipment ratings  7
External plugs numbering  12

F

Fuse replacement  7

Fuse specifications  7

G

General description  5
General information  4

H

How to order  16

M

Meaning of external commands  11
Monitor signals  15

P

Power-up procedure  10

R

RoHS conformity 2

T

Technical assistance  16

W

Warnings  4
Wiring diagram FR/CR > TI020 v.1  13
Wiring diagram FR/CR > TI020 v.3  14
Wiring diagram FR/CR > TX020   15
Wiring  instructions  9

Indice

A

Avvertenze  4
Assistenza tecnica  16

C

Caratteristiche elettriche  7

Caratteristiche fisiche  6

Condizioni ambientali di utilizzo  6

D

Descrizione generale  5
Descrizione dei comandi esterni  11
Dichiarazione CE di conformità  1

F

Fusibile  7

I

Informazioni generali  4
Installazione dell’apparecchiatura  8
Istruzioni di collegamento  9

M

Manutenzione  8
Messa in funzione  10
Modalità d’ordine  16

N

Numerazione morsetti volanti

P

Pulizia  8

R

RoHS conformità normativa  2

S

Schema collegamento FR/CR > TI020 v.1  13
Schema collegamento FR/CR > TI020 v.3  14
Schema collegamento FR/CR > TX020  15
Segnali di monitor  15
Sostituzione fusibile  7

Summary of Contents for CR 840

Page 1: ...FR 840T FIXED OUTPUT CR 840T ADJUSTABLE OUTPUT SWITCHING POWER SUPPLIES FOR 2KW MAGNETRON TECHNICAL NOTE Bilingual issue EN IT April 2017 FR 840 CR 840...

Page 2: ...Cover Rear...

Page 3: ...ion of the laws of the member States relating to electromagnetic compatibility Riavvicinamento delle legislazioni degli Stati membri relative alla compatibilit elettromagnetica Conformity to the Direc...

Page 4: ...may be charged with a fine or prosecuted by law Riduzione delle Sostanze Pericolose RoHS e Smaltimento di Apparecchiature Elettriche ed Elettroniche RAEE o parti delle stesse Riferimenti Normativi Dir...

Page 5: ...020 v 1 13 Wiring diagram FR CR TI020 v 3 14 Wiring diagram FR CR TX020 15 Wiring instructions 9 Indice A Avvertenze 4 Assistenza tecnica 16 C Caratteristiche elettriche 7 Caratteristiche fisiche 6 Co...

Page 6: ...eral malfunctions of the equip ment itself Informazioni generali L alimentatore FR CR 840T conforme alla Norma Europea EN 61010 1 CEI 66 5 approvata dal CENE LEC il 9 3 1993 Come previsto da tale norm...

Page 7: ...laced at a distance that do not reduce air flow on the unit See the following drawing Descrizione generale L FR840T un alimentatore in tecnologia switching a potenza fissa per magnetron da 2kW 2 45GHz...

Page 8: ...NCO ON quando il contatto chiuso OK MICROWAVE ON BLU ON quando il magne tron sta erogando microonde comando di abilitazione ON ALARM ROSSO ON quando presente un allarme Environmental Physical Characte...

Page 9: ...D unit in power ON no alarms MW Ready output contacts rating V A 24 0 5 CLOSED unit in power ON no alarms preheating completed OPEN unit in power OFF or alarm status or filament preheating not complet...

Page 10: ...ion between the air intake and the air outlets in order to avoid air recyrculating Manutenzione dell apparecchiatura Pulizia Verificare una volta al mese che la griglia d ingresso o d uscita siano pul...

Page 11: ...LTER may supply the HV cable with lenght on request VI the user must provide external cut off device to pro tect the FR CR from short citcuit and thermal runaway Istruzioni di collegamento Le operazio...

Page 12: ...ALTER pu fornire il cablaggio di alta tensione nella lunghezza richiesta VI installare un interruttore esterno quadripolare con fun zioni di protezione termica dal cortocircuito e consentire di sezion...

Page 13: ...loses whenever the unit is actually outputting microwaves pin 8 9 In tutti questi casi tranne che in quello di interruzione dell ABILITAZIONE il contattio di allarme si apre e il LED rosso lampeggia I...

Page 14: ...ife may be shorter than expected Solo per il CR 840 RIFERIMENTO nella versione 0 un ingresso analo gico 1 10V che fissa il livello di potenza in uscita dal 10 100 come indicato nel diagramma che segue...

Page 15: ...File FR CR840_r3 April 2017 Technical note FR CR page 13 of 16 FR 840 CR 840 Wiring diagram FR CR TI020 v 1 Schema di collegamento FR CR TI020 v 1...

Page 16: ...page 14 of 16 File FR CR840_r3 April 2017 Technical note FR CR FR 840 CR 840 Schema di collegamento FR CR TI020 v 3 Wiring diagram FR CR TI020 v 3...

Page 17: ...EGNALI DI MONITOR valid for all versions valido per tutte le versioni Magnetron voltage and current Monitor CONN J1 pin Output Voltage Va 1 Vmon 1000 V Pin 21 return on pin 20 Output Current Ia 1 Vmon...

Page 18: ...al assistance For technical assistance as well as spare parts contact your closest distributor or Modalit d ordine Alimentatore FR840T Potenza d uscita fissa CR840T Potenza d uscita regolabile version...