24
MK-20 SERIES oPERATIoN
BlAdE GUARd REPoSITIoNING
(A)
Remove Diamond Blade.
(B)
Remove the Cooling Transfer
Hose from the Blade Guard by
pressing the quick release.
(D)
Remove the Blade Guard
Retaining Bolts and remove the
Blade Guard.
(C)
Locate the four Blade Guard Re-
taining Bolts.
(E)
Locate the Blade Shaft Cover
Retaining Bolts.
(F)
Remove the Blade Shaft Cover
Retaining Bolts and the Blade
Shaft Cover.
(G)
Install the Blade Guard on the
opposite side of the saw.
.
(H)
Install Diamond Blade
(I)
Install the Cooling Transfer Hose
to the Blade Guard.
Do not operate saw with any guards removed. Turn master engine switch to off
position to avoid accidental starts when removing guards.
WARNING