CHAPTER 6
ELECTRICAL SYSTEM
- 31 -
34z
TURN BREAKERS ON for the
items you wish to operate.
Note: if the generator starts, but no
AC voltage is seen at the panel,
check first that the selector
switches (sliding interlocks) at the
top of the AC panel are ON. If so,
there is a possibility the generator
was overloaded and the AC
breaker on the generator Control
Box has tripped due to a
momentary overload. Open the
generator cover and reset (pull up)
the AC Output Circuit Breaker
TO STOP: Remove electrical load
from the generator by turning off all
breakers. Allow the generator to
run for a 3-5 minute cool-down
period. Depress STOP momentarily
on the lower part of the rocker
switch.
Generator Fuel Pre-Filter
is
located behind the genset against
the bulkhead.
GENSET Water/Exhaust Separator Overboard Discharge Thruhull
Located aft to starboard, under the waterline, outboard of engine intake
grill in engine room