2
DO NOT
operate in dirty or
dusty environment, do
clean fixtures regularly.
DO NOT
touch any wire during opera on as there might be a hazard of electric shock.
Avoid power wires together twist other cables.
The minimum distance between light output and the illuminated surface must be more than 12
meters.
Disconnect mains power before fuse/lamp replacement or servicing.
Replace fuse/lamp only with the same type.
In the event of serious opera ng problem, stop u sing the unit immediately.
Never turn on and off the unit me a er me.
The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly damaged.
DO NOT open the unit as there are no user serviceable parts inside.
Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage
or malfunc on. Please contact the nearest authorized technical assistance center if needed.
Disconnect the mains power if the fixture is
has
not
been
used for a long me.
DO use the original packing materials before transporting
it again.
Cau ons:
To prevent or reduce the risk of electrical shock or fire, do not expose the unit to rain or moisture.
Hot lamp explosion hazard. DO NOT
open the unit within 15 minutes a er switching off.
DO replace the bulb once it is damaged, deformed or life-expired.
DO NOT
look directly at the light while the bulb is on.
Never touch bulb with bare fingers, as it is very hot a er using.
DO NOT
start on the unit without bulb enclosure or when housing is damaged.
Installa on:
The unit
is fully opera onal in three
different moun ng posi ons, hanging upside-down from a ceiling
or set on a flat level surface. To avoid internal damage to the unit, never mount the unit on its side as
illustrated above. Be sure this fixture is kept at least 0.5m away from any flammable materials
(decora on etc.). Always use and install the supplied safety cable as a safety measure to prevent
accidental damage and/or injury in the event the clamp fails.
23
200-209
210-219
220-229
230-255
All reset
Enable blackout while Pan/Tilt Color Gobo Moving
Disable blackout while Pan/Tilt Color Gobo Moving
No func on
7 . Troubleshoo ng
Following are a few common problems that may occur during opera on. Here are some sugges ons
for easy troubleshoo ng:
A. The unit does not work, no light and the fan does not work
1.
Check the connect power and main fuse.
2.
Measure the mains voltage on the main connector.
3.
Check the power on LED
to see if it can be light up or not.
B. Not responding to DMX controller
1.
DMX LED should be on. If not, check DMX connectors, cables to see if
they are linked properly.
2.
If the DMX LED is on and no response to the channel, check the address se ngs and DMX
polarity.
3.
If you have intermi ent DMX signal problems, check the pins on connectors or on PCB of the unit
or the previous one.
4.
Try to use another DMX controller.
5.
Check to see if the DMX cables run near or run alongside to high voltage cables that may cause
damage or interference to DMX interface circuit.
C. One of the channels is not working well
1.
The stepper motor might be damaged or the cable connected to the PCB is broken.
2.
The motor’s drive IC on the PCB might be out of condi on.
D. The lamp is cu ng out intermi ently
1.
The lamp is not working well. Check the mains voltage either too high or too low.
2.
Internal temperature may be too high. Check if replacement of fan is needed on the head.