background image

 

 

 

1

 

 

 

 

 

 

 

1. Safety Instruc ons  

 

 

WARNING 

 

Please keep this User Guide for future consulta on. If you sell the unit to another user, be sure that 

they also receive this instruc on manual. 

Important:

 

Damages caused by the disregard  of this user manual  are not subject to warranty. The dealer 

will not accept liability for any resul ng defects or problems

 

Unpack and check carefully that there is no transporta on damage before using the unit.

 

The unit is for indoor use only. Use only in a dry loca on.

 

 

DO install and operate by qualified operator.

 

 

DO NOT allow children to operate the fixture.

 

 

Use safety chain when fixing

 

the unit. Handle the unit by carrying its base instead of head only.

 

The  unit  must  be  installed  in  a  loca on  with  adequate  ven la on,  at  least  50cm  from  adjacent 

surfaces. 

 

 

Be sure that no ven la on slots are blocked, otherwise the unit will be overheated.

 

Before  opera ng,  ensure  that  the  voltage  and  frequency  of  power  supply  match  the  power 

requirements of the unit.

 

 

It’s important to

 

ground the yellow/green conductor to earth in order to avoid electric shock.

 

Maximum ambient temperature TA: 40

. DO NOT

 

operate it when

 

the temperature is higher.

 

DO NOT connect the device to any dimmer pack.

 

During  ini al  start-up  some  smoke  or  smell  may  arise.  This  is  a  normal  process  and  does  not 

necessarily mean that the device is defec ve, and it will decrease gradually within 15 minutes. 

 

Make sure there are no flammable materials close to the unit while opera ng

 

to avoid fire hazard.

 

Examine the power wires carefully; replace them immediately if there is any damage.

Unit’s surface temperature may reach up to 85

. DO NOT touch the housing bare-handed during 

its  opera on,  and  allow  about  15  minutes  for  cooling  the  unit  down  before  replacing  bulb  or 

maintenance as it could be very hot.

Avoid any inflammable liquids, water or metal objects entering the unit. Once it happens, cut off 

Please read the instruc on carefully which includes important informa on about 

the installa on, usage and maintenance.

 

the mains power immediately.

 

 

 

24

 

 

 8 . Cleaning 

 

The cleaning of internal and external op cal lenses and/or mirrors must be carried out periodically 

to  op mize  light  output.  Cleaning  frequency  depends  on  the  environment  in  which  the  fixture 

operates: damp, smoky or par cularly dirty surrounding can cause greater accumula on of dirt on the 

unit’s op cs.

 

Clean with so  cloth and use normal glass to clean liquid. 

Always dry the parts carefully.

Clean the external op cs at least every 20 days. Clean the internal op cs at least every 30/60 days.

Important no ce:

• 

In this instruc on for use contains about the installment and the use aspect 

important informa on of the LED BSW moving head. When installing and using, you 

need to look this usage instruc on strictly.
• Before open the LED moving head and if you want to do the repair work, please 

make sure the power source is at the separa on condi on.
• Every unit is tested completely and packed properly by the manufacturer. Please 

make sure the packing and the unit are in good condi on before installa on and use. 

Should there be any damage caused by transporta on, consult your dealer and do not 

use the unit. Any damage caused by improper use will not be assumed by the 

manufacturer or dealer.

A en on: 

Unceasingly carries on the product improvement about our company the 

policy, in this instruc on booklet carries the data will have the possibility to be able to 

change in the future, when no longer separate no ce change ma ers concerned. Our 

company retains when the product improvement changes the related specifica on 

the authority. This instruc on booklet publisher cannot be responsible regarding this 

instruc on booklet in informa on accuracy, also cannot the related consequence 

which causes regarding these informa on be responsible.

Summary of Contents for MJ-1057

Page 1: ...D MJ 1057 User Manual Thank you for choosing our LED BSW moving head light For the sake of your safety Please read and follow these instructions carefully and keep this manual in a safe place for future reference PROFESSIONAL LED LIGHTING ...

Page 2: ...ntrol Panel 4 4 Gobo and Lamp 5 4 1 Gobos 5 5 How To Set The Unit 5 5 1 Main Func on 5 5 2 Home Posi on Adjustment 11 5 3 Error Informa on 13 6 Control By Universal DMX Controller 14 6 1 Connec on 14 6 2 Address Se ng 15 6 3 DMX 512 Configura on 15 7 Troubleshoo ng 23 8 Cleaning 24 ...

Page 3: ...d any inflammable liquids water or metal objects entering the unit Once it happens cut off Please read the instruc on carefully which includes important informa on about the installa on usage and maintenance the mains power immediately 24 8 Cleaning The cleaning of internal and external op cal lenses and or mirrors must be carried out periodically to op mize light output Cleaning frequency depends o...

Page 4: ...eiling or set on a flat level surface To avoid internal damage to the unit never mount the unit on its side as illustrated above Be sure this fixture is kept at least 0 5m away from any flammable materials decora on etc Always use and install the supplied safety cable as a safety measure to prevent accidental damage and or injury in the event the clamp fails 23 200 209 210 219 220 229 230 255 All res...

Page 5: ...r changing Enable blackout while Gobo changing Disable blackout while Gobo changing No func on Pan Tilt reset Effect reset No func on 150 2 Technical Specifica ons Power supply AC 100 240V 50 60Hz Power Consump on 189W Light Source 1 X W LED Angle Beam Angle 11 on full open 2 4 6 8 10 with beam reducer 3 6 9 12 15 20 with zoom lens Spot Angle Fix Gobo 2 15 with zoom lens Rota ng Gobo 10 17 with zoom...

Page 6: ...4 127 128 189 190 193 194 255 Color10 Color11 Color12 Color13 Color14 Color15 Color16 Color wheel indexing Counter Clockwise rota on fast to slow Stop Clockwise rota on slow to fast 10 000 007 008 016 017 025 026 034 035 043 044 052 053 061 062 067 068 127 128 189 190 193 194 255 GOBO WHEEL 1 Open Gobo1 1 Gobo1 2 Gobo1 3 Gobo1 4 Gobo1 5 Gobo1 6 Gobo1 7 Gobo1 1 7 shaking Counter Clockwise rota on f...

Page 7: ...last menu Press the MENU bu on or let the unit idle one minute to exit menu mode In the event of disconnec ng with mains power press the UP bu on for one minute to enter into menu mode Press MENU bu on or let the unit idle one minute to exit The main func ons are shown below the grayed boxes are preset se ngs 20 032 039 040 047 048 055 056 063 064 071 072 079 080 087 088 095 096 103 104 111 112 11...

Page 8: ...le Pan Tilt Moving Disable blackout while Pan Tilt Moving Enable blackout while Color changing Disable blackout while Color changing Enable blackout while Gobo changing Disable blackout while Gobo changing No func on Pan Tilt reset Effect reset No func on All reset Enable blackout while Pan Tilt Color Gobo Moving Disable blackout while Pan Tilt Color Gobo Moving No func on 20 Channels Mode 2 CHANNE...

Page 9: ... mode press the ENTER bu on to store Press the MENU bu on back to the last menu or let the unit idle one minute to exit menu mode DMX State fixture state while DMX single stops To select DMX State press the ENTER bu on to confirm Use the UP DOWN bu on to select Master Slave fixture enters to master slave mode Blackout fixture blacks out if DMX signal stops or Hold fixture con nues to obey the last comm...

Page 10: ...let the unit idle one minute to exit menu mode Show Se ng To select Show Se ng press the ENTER bu on to confirm use the UP DOWN bu on to select Show Mode Slave Mode or Sound Sense Show Mode To select Show Mode press the ENTER bu on to confirm Use the UP DOWN bu on to select show1 show 2 show 3 or show 4 press the ENTER bu on to store Press the MENU bu on back to the last menu or let the unit idle on...

Page 11: ...de selectDisplay Se ng press the ENTER bu on to confirm use the UP DOWN bu on to select Display Inverse Contrast Ra o Temperature Unit or Language Display Inverse Select Display Inverse press the ENTER bu on to confirm present mode will blink on the display use the UP DOWN bu on to selectNo normal display or Yes inverse display pressthe ENTER bu on to store Press the MENU bu on back to the last men...

Page 12: ...n to select Yes the unit will run built in program to reset pan and lt to their home posi ons or No normal press the ENTER bu on to store Pressthe MENU bu on back to the last menu or let the unit idle one minute to exit menu mode 15 5 The end of the DMX 512 system should be terminated to reduce signal errors 6 3 pin XLR connectors are more popular than 5 pins XLR 3 pin XLR Pin 1 GND Pin 2 Nega ve ...

Page 13: ...f the last fixture number is between 0 511 usually 0 1 are equal to 1 11 Effect Reset Effect Select Effect press the ENTER bu on to confirm use the UP DOWN bu on to select Yes the unit will run built in program to reset effect to their home posi ons or No press the ENTER bu on to store Press the MENU bu on back to thelast menu or let the unit id le one minute to exit menu mode All Reset All Select All p...

Page 14: ... MENU bu on to exit R Prism Prism rota on home posi on adjustment Enter offset mode SelectR Prism press the ENTER bu on to confirm the present posi on will blink on the display use the UP DOWN bu on to offset the value from 128 to 127 press the ENTER bu on to store Press the MENU bu on to exit 13 Beam Frost Beam Frost home posi on adjustment Enter offset mode SelectBeam Frost pressthe ENTER bu on to c...

Reviews: