background image

 

9

 

 

White Current: White current adjust 

 

Factory set: you can set all parameters to factory set. 

Test mode

,

 test mode is a special mode,

 

only can be used when it is in test mode interface,

 

exit interface, 

then return to previous running mode.

 

In the test mode,

 

you can adjust Pan,

 

tilt and focus motor’s 

position,

 

also can adjust    intensity of RGBW color.

 

The RGBW color of test mode can be used by the 6

th

 

channel in the DMX mode. 

Sys info

 : display related information on system 

 

DMX address 

 

Running mode: System running mode currently 

 

ON time: The current time when you power on it 

 

Run time: Total time of using this light 

 

Temperature: Display current temperature 

 

Ver: current verson of software 

 

Control panel of LED display information: 

 

 

Green 

On 

DMX signal ok 

Off 

No DMX signal 

Flash 

DMX signal error 

Red 

On 

Err 

 

Maintenance:   

To prolong the life of the projector, some maintenance work has to be done to ensure the LED 
optical system in good condition. If the projector does not function, check the fuses on the power 
socket of the projector, they should only be replaced by fuses of the same specification. Should 
these be damaged, call a qualified technician before replacement. The projector has thermal 
protection device that will switch off the projector in case of overheating. Should either of these 
operate, check that the fans are not blocked, and if they are dirty, clean them before switching on the 
projector again. Check that the fans are operational, if not, call a qualified technician. 

Any maintenance work should only be carried out by qualified technicians. 

 

Keeping The Product Clean: 

To ensure the reliability of the projector, it should be kept clean. It is recommended that the fans 
should be cleaned every 15 days. LED lens should also be regularly cleaned to maintain an optimum 
light output. 
Cleaning frequency depends on the environment in which the fixture operates: damp, smoke or 
particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics. A soft cloth 
and typical glass cleaning products should be used for cleaning. It is recommended to clean the 
external optics at least once every 15 days. 

Do not use any organic solvent, e.g. alcohol, to clean housing of the apparatus. 

Summary of Contents for MJ-1029A

Page 1: ...29A User Manual PROFESSIONAL LED LIGHTING Thank you for choosing our LED zoom moving head light For the sake of your safety Please read and follow these instructions carefully and keep this manual in a safe place for future reference ...

Page 2: ...ry unit is tested completely and packed properly by the manufacturer Please make sure the packing and the unit are in good condition before installation and use Should there be any damage caused by transportation consult your dealer and do not use the unit Any damage caused by improper use will not be assumed by the manufacturer or dealer Attention Unceasingly carries on the product improvement ab...

Page 3: ...h the power requirements of the projector It is essential that each projector is correctly earthed and that electrical installation conforms to all relevant standards Do not connect this device to any other types of dimmer apparatus Make sure that the power cord is never crimped or damaged by sharp edges Never let the power cord come into contact with other cables Only handle the power cord by the...

Page 4: ...ht Do not use clamp as a tool to move fixtures 2 Base on safety reason please use the safety cord which can afford the weight ten times of lamp through Insurance hole for auxiliary hanging 3 Don t use the handle of the moving head light to fixed or lift Power Code Connection Connect the power cord as follows L live brown E earth yellow green N neutral blue Use the plug provided to connect the main...

Page 5: ...nnect the controller s output to the first fixture s input and connect the first fixture s output to the second fixture s input and connect the rest fixtures in the same way Eventually connect the last fixture s output to a DMX terminator DMX Terminator In the Controller mode at the last fixture in the chain the DMX output has to be connected with a DMX terminator This prevents electrical noise fr...

Page 6: ... picture 2 Each menu all represent the specific functions of lamps specific see below operation menu section Set or browse function setting of lamp Press UP or DOWN key Press ENTER key to save your changes or to ENTER submenu Touch UP or DOWN can change value Plus or reduce number According to the Return key to return to the last menu Operation Menu Menu Structure chart Main Menu Sub Menu DMX Addr...

Page 7: ...otal time of using Soft ver Running Mode Dmx Address Temperature Set Temperature Display current temperature 0 25 ON OFF ON OFF ON OFF 0 255 0 255 ON OFF 50 C 85 C Green Current Handspike Delay ON OFF ON OFF ON OFF Blue Current ON OFF 200 20 255 200 20 255 200 20 255 XF03 H M S H M Signal Link ON OFF Focus Calibration 0 255 Code Wheel ON OFF Screen Rot ON OFF White Current 200 20 255 ...

Page 8: ...eration Reset can be max travel reset from code wheel reset Signal link When turn on signal link cut off control signal will be remain disconnected before the control signals Handspike delay when switch on handspike delay the controller handspike can achieve soft dimming effect Handspike delay can be chosen ON OFF on the controller ID code ID code is using for DMX mode in the channel16th when the ...

Page 9: ... socket of the projector they should only be replaced by fuses of the same specification Should these be damaged call a qualified technician before replacement The projector has thermal protection device that will switch off the projector in case of overheating Should either of these operate check that the fans are not blocked and if they are dirty clean them before switching on the projector agai...

Page 10: ...well or broken The light beam appears gloomily Check that the heat dissipation system is running normally or Inspect the optics part is whether clean Other maintain work should by the specialist which has the experience to carry on Equipment and Appendix The packing list of this light as follows Led zoom moving head light 1pcs Power Cable 1pcs XLR connector 1unit Light Hook 2pcs The Product of Ins...

Page 11: ...0 255 B3 dimmer from dark to bright 20 0 255 W3 dimmer from dark to bright 0 5 Do not use macro function 6 20 Choice color Motor is control by DMX512 21 40 Color jumping change Motor is control by DMX512 41 60 Color fading change Motor is control by DMX512 61 80 Color pulsing change Motor is control by DMX512 21 13 81 100 Sound control 1 Motor is control by DMX512 101 120 Sound control 2 Motor is ...

Page 12: ...be 1 25 second high speed strobe but single color Mixes the color strobe Head Movement Pan 540 Tilt 270 with auto position correction and electronic replacement function Beam Angle 15 60 Control mode DMX 512 Stand alone mode Sound Master slave DMX Channel 14 22CH Control Panel LCD display panel IP Grade IP20 Work Environment Temperature 20 C 40 C Other Functions Pan and Tilt speed adjustable LCD D...