9
White Current: White current adjust
Factory set: you can set all parameters to factory set.
Test mode
,
test mode is a special mode,
only can be used when it is in test mode interface,
exit interface,
then return to previous running mode.
In the test mode,
you can adjust Pan,
tilt and focus motor’s
position,
also can adjust intensity of RGBW color.
The RGBW color of test mode can be used by the 6
th
channel in the DMX mode.
Sys info
: display related information on system
DMX address
Running mode: System running mode currently
ON time: The current time when you power on it
Run time: Total time of using this light
Temperature: Display current temperature
Ver: current verson of software
Control panel of LED display information:
Green
On
DMX signal ok
Off
No DMX signal
Flash
DMX signal error
Red
On
Err
Maintenance:
To prolong the life of the projector, some maintenance work has to be done to ensure the LED
optical system in good condition. If the projector does not function, check the fuses on the power
socket of the projector, they should only be replaced by fuses of the same specification. Should
these be damaged, call a qualified technician before replacement. The projector has thermal
protection device that will switch off the projector in case of overheating. Should either of these
operate, check that the fans are not blocked, and if they are dirty, clean them before switching on the
projector again. Check that the fans are operational, if not, call a qualified technician.
☆
Any maintenance work should only be carried out by qualified technicians.
Keeping The Product Clean:
To ensure the reliability of the projector, it should be kept clean. It is recommended that the fans
should be cleaned every 15 days. LED lens should also be regularly cleaned to maintain an optimum
light output.
Cleaning frequency depends on the environment in which the fixture operates: damp, smoke or
particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics. A soft cloth
and typical glass cleaning products should be used for cleaning. It is recommended to clean the
external optics at least once every 15 days.
☆