background image

                                                                                Zoom Moving Head Wash 3610 MJ-1006B User Manual ver2.0 

                                                                                                                   

www.mjledlighting.com

   

12

 

 

 

 

 

241-245 

R255 G255 B185 W255 

246-250 

R255 G255 B197 W255 

251-255 

R255 G255 B234 W255 

16 

0-9 

IDcode fail 

10-19 

ID1 

20-29 

ID2 

30-39 

ID3 

40-49 

ID4 

50-59 

ID5 

60-69 

ID6 

70-79 

ID7 

80-89 

ID8 

90-99 

ID9 

100-109 

ID10 

110-119 

ID11 

120-129 

ID12 

130-139 

ID13 

140-149 

ID14 

150-159 

ID15 

160-169 

ID16 

170-179 

ID17 

180-189 

ID18 

190-199 

ID19 

200-209 

ID20 

210-219 

ID21 

220-229 

ID22 

230-239 

ID23 

240-249 

ID24 

250-255 

ID25 

 

   

12CH MODE 

Channel  Value 

Control function 

0-255 

Main dimming 

0-255 

Red 

0-255 

Green 

0-255 

Blue 

0-255 

White 

0-255 

User customs color 

0-255 

Pan 

0-255 

Tilt 

0-255 

Pan fine

16Bit

 

10 

0-255 

Tilt fine

16Bit

 

11 

0-255 

XYmotor speed from quick to slow 

12 

0-255 

F motor 

 

 

Summary of Contents for MJ-1006B

Page 1: ...HEAD LIGHT MJ 1006B User Manual Thank you for choosing our LED moving head light For the sake of your safety Please read and follow these instructions carefully and keep this manual in a safe place for future reference ...

Page 2: ...ion condition Every unit is tested completely and packed properly by the manufacturer Please make sure the packing and the unit are in good condition before installation and use Should there be any damage caused by transportation consult your dealer and do not use the unit Any damage caused by improper use will not be assumed by the manufacturer or dealer Attention Unceasingly carries on the produ...

Page 3: ...age and frequency of power supply match the power requirements of the projector It is essential that each projector is correctly earthed and that electrical installation conforms to all relevant standards Do not connect this device to any other types of dimmer apparatus Make sure that the power cord is never crimped or damaged by sharp edges Never let the power cord come into contact with other ca...

Page 4: ... 1 Hook and clamp only use for hanging the light Do not use clamp as a tool to move fixtures 2 Base on safety reason please use the safety cord which can afford the weight ten times of lamp through Insurance hole for auxiliary hanging 3 Don t use the handle of the moving head light to fixed or lift Power Code Connection Connect the power cord as follows L live brown E earth yellow green N neutral ...

Page 5: ...LR plugs and sockets The XLR s are connected as shown in the figure above Note Care should be taken to ensure that none of the pins touch the metallic body of the plug or each other The body of the plug is not connected in any way The XLED 590 accepts digital control signals in protocol DMX512 1990 Connect the controller s output to the first fixture s input and connect the first fixture s output ...

Page 6: ...en the LCD is off When the LCD display the main menu touch the menu into sub menu as picture 1 Use button switch and LCD display can set the address code and function code easily Check or modify lighting function settings Touching the LCD display panel LCD displaypanelwilldisplay function menu of lighting Function operation menu all have corresponding submenu as picture 2 Each menu allrepresent th...

Page 7: ...Sound Mode Pan test Titl 0 255 Green 0 255 Red 0 255 White 0 255 Blue 0 255 Language Chinese English Set Up ID Code Pan Reverse Tilt Reverse Fader Delay Signal Link Code Wheel Temp Switch Set Fan Speed Screen Protect Temperature Set Focus 0 255 Return 16CH 12CH Auto1 Auto8 0 255 0 255 0 255 0 255 0 255 0 255 0 255 Return 0 25 ON OFF OFF MODE1 MODE2 ON OFF ON OFF ON OFF ON OFF ON OFF 50 120 0 255 R...

Page 8: ...is Master signal then it is running slave mode Auto mode auto mode also can be master mode When the light in sound mode it can t be master mode 3 Test mode test mode is a special mode only can be used when it is in test mode interface exit interface then return to previous running mode In the test mode you can adjust Pan tilt and focus motor s position also can adjust intensity of RGBW color The R...

Page 9: ...an be set turn off mode1 and mode 2 When it s OFF then won t enter screen protect condition When in mode 1 it will clear the screen When in mode 2 after you into screen protection big letter display current address code Touch the screen you can exit screen protect condition and return main menu Screen Rot this menu can let the screen inversion 180 degree Logo if display logo Factory set you can se...

Page 10: ...cause greater accumulation of dirt on the unit s optics A soft cloth and typical glass cleaning products should be used for cleaning It is recommended to clean the external optics at least once every 15 days Do not use any organic solvent e g alcohol to clean housing of the apparatus Trouble Shooting Problem Answer The LED moving head light doesn t switch on Check the fuse the power socket Althoug...

Page 11: ...andspike 51 90 Program color selection switch 91 130 Pulse change 131 170 Jump change 171 210 fade 211 250 Inside mode 1 can t be controlled 251 255 Sound mode can t be controlled 15 0 255 pulse jump fade from slow to quick CH14 is 91 210 之间 0 Can t use color selection function 1 20 R255 G B0 W0 21 40 R G255 B0 W0 41 60 R0 G255 B W0 61 80 R0 G B255 W0 81 100 R G0 B255 W0 101 120 R255 G0 B W0 121 1...

Page 12: ... 109 ID10 110 119 ID11 120 129 ID12 130 139 ID13 140 149 ID14 150 159 ID15 160 169 ID16 170 179 ID17 180 189 ID18 190 199 ID19 200 209 ID20 210 219 ID21 220 229 ID22 230 239 ID23 240 249 ID24 250 255 ID25 12CH MODE Channel Value Control function 1 0 255 Main dimming 2 0 255 Red 3 0 255 Green 4 0 255 Blue 5 0 255 White 6 0 255 User customs color 7 0 255 Pan 8 0 255 Tilt 9 0 255 Pan fine 16Bit 10 0 ...

Page 13: ...1 25 second high speed strobe but single color Mixes the color strobe Head Movement Pan 630 Tilt 270 with auto position correction and electronic replacement function Beam Angle 10 60 Control mode DMX 512 Stand alone mode Self test mode Sound Master slave DMX Channel 12CH 16CH Control Panel LCD display panel IP Grade IP20 Work Environment Temperature 20 C 40 C Other Functions Pan and Tilt speed ad...