Installation: electrical
7. Remove the Mixergy cylinder controller's top cover by unscrewing
the screws shown below and pulling the cover away.
8. Unplug the pump from the cylinder controller.
9. Plug the pump cable into either pump port on the PV switch.
10. Plug the included pump extension lead from the second pump
port on the PV switch to the pump port on the cylinder controller.
11.
If the immersion thermostat is not already adjusted to maximum,
or the thermostat is being replaced, ensure that the thermostat
is adjusted to its highest set temperature.
12. Replace immersion cover, PV switch cover and cylinder controller
cover.
7