Included items

Installation: general guidelines

•  MAS0086-01 PV ready switch box complete
•  MEL0049 2m pump cable extension
•  2x MME0077 Screw No 8 x 13mm Self Drilling
•  2x MME0152 Plastic spacer
•  Installation guide

Ensure that all mains cabling used has a minimum CSA of 1.5 mm

2

 

with a minimum temperature rating of 90C (H05V2V2-F).

Avoid  fitting  the  PV  switch  or  making  electrical  junctions  directly 

underneath water pipework.

The PV switch can be fixed to the outer wrapper of the cylinder using 

the two self drilling screws or to an adjacent wall using the provided 

plastic spacers. In the case of a wall-mount, the immersion cable will 

need to be extended. Ensure that the junction used to perform this 

extension has a minimum IP41 rating and is appropriately rated to 

handle 240V~ 13A continuous.

ENSURE ALL ELECTRICAL SUPPLIES ARE SWITCHED 

OFF BEFORE MAKING ANY CONNECTION TO 

THE UNIT. ELECTRICAL INSTALLATION MUST BE 

CARRIED OUT BY  COMPETENT ELECTRICIAN 

AND BE IN ACCORDANCE WITH THE LATEST I.E.E. 

REGULATIONS.

Summary of Contents for MDC0014-02

Page 1: ...Installation and commissioning instructions MDC0014 02 For Mixergy PV switch...

Page 2: ...y device which allows for external 3rd party PV diverters to be integrated with the Mixergy cylinder and share use of the primary immersion Under idle conditions control of the immersion is given to t...

Page 3: ...t this module 2 Technical data 2 Contents 3 Included items 4 Installation general guidelines 4 Installation mechanical 5 Installation electrical 6 Installation commissioning 8 Troubleshooting 8 Replac...

Page 4: ...th water pipework The PV switch can be fixed to the outer wrapper of the cylinder using the two self drilling screws or to an adjacent wall using the provided plastic spacers In the case of a wall mou...

Page 5: ...ither to the side wall of the cylinder using the included self drilling screws or to a nearby wall using the included plastic spacers 3 Remove the cover cap on the primary immersion heater Disconnect...

Page 6: ...5mm2 CSA 3 core H05V2V2 F flex if required 5 Wire the external diverter s immersion supply cable into the ter minals PVL L PVN N GND E on the PV switch 6 Wire an appropriate length of minimum 1 5mm2 C...

Page 7: ...either pump port on the PV switch 10 Plug the included pump extension lead from the second pump port on the PV switch to the pump port on the cylinder controller 11 If the immersion thermostat is not...

Page 8: ...Troubleshooting Diverter not working correctly If the diverter is unable to supply heat to the cylinder perform the following checks Check that the cylinder is not entirely full of hot water i e 100 c...

Page 9: ...parts of the Mixergy cylinder unless you are a trained operative If you suspect a fault or a replacement part is needed please contact Mixergy directly Part description Part no PV Switch PCBA MAS0085...

Page 10: ...at mixergy co uk email us at enquiries mixergy co uk or call us on 01865 884 343 Mixergy Ltd 2 Canal View Wharf Farm Eynsham Road Cassington Oxfordshire OX29 4DB T 01865 884 343 www mixergy co uk MIX...

Reviews: