4
Included items
Installation: general guidelines
• MAS0086-01 PV ready switch box complete
• MEL0049 2m pump cable extension
• 2x MME0077 Screw No 8 x 13mm Self Drilling
• 2x MME0152 Plastic spacer
• Installation guide
Ensure that all mains cabling used has a minimum CSA of 1.5 mm
2
with a minimum temperature rating of 90C (H05V2V2-F).
Avoid fitting the PV switch or making electrical junctions directly
underneath water pipework.
The PV switch can be fixed to the outer wrapper of the cylinder using
the two self drilling screws or to an adjacent wall using the provided
plastic spacers. In the case of a wall-mount, the immersion cable will
need to be extended. Ensure that the junction used to perform this
extension has a minimum IP41 rating and is appropriately rated to
handle 240V~ 13A continuous.
ENSURE ALL ELECTRICAL SUPPLIES ARE SWITCHED
OFF BEFORE MAKING ANY CONNECTION TO
THE UNIT. ELECTRICAL INSTALLATION MUST BE
CARRIED OUT BY COMPETENT ELECTRICIAN
AND BE IN ACCORDANCE WITH THE LATEST I.E.E.
REGULATIONS.