(g) In case drain hose will freeze.
– 57 –
Is battery
voltage measured at LW
line of drain hose heater
connector?
Drain hose heater is defective.
NO
YES
Is battery
voltage measured at BrR
line of drain hose heater
connector?
LW line between fuse (F
1
) and
drain hose heater is broken of
contact of connector is
defective.
BR line between controller and
relay box AR
7
is broken or
contact of connector is
defective.
• AR
7
relay is defective.
• BrR and G lines between
drain hose heater and relay
box (AR
7
) are broken or
contact of connector is
defective.
NO
Refer to page 55, defrost
operation.
Is defrost operation
normally made?
NO
YES
YES
Is battery
voltage measured at BR
line of AR
7
coil?
NO
WR line of AR
7
coil is broken
or defective.
Is
WR line of AR
7
coil
under 0.5V?
NO
(Battery voltage)
YES
YES
Drain hose will freeze.