 1. Overview 

 

 

This manual explains how to handle the MELSECNET/H network module, model 
numbers QJ72LP25-25, QJ72LP25G and QJ72BR15 (hereinafter referred to as 
the network module). 
This network module is used as a remote I/O station of a remote I/O network in 
the MELSECNET/H network system, not in a PLC to PLC network. 
After unpacking the network module, confirm that any of the following products is 
enclosed. 
 

Model name 

Part name 

Quantity 

QJ72LP25-25 

QJ72LP25-25 MELSECNET/H Network Module 
(optical loop type) 

QJ72LP25G 

QJ72LP25G MELSECNET/H Network Module 
(optical loop type) 

QJ72BR15 MELSECNET/H Network Module 
(coaxial cable bus type) 

QJ72BR15 

F-type connector (A6RCON-F) 

 

Important 

The coaxial bus-type network system requires terminal resistors at both terminal 
stations of the network. Terminal resistors are not included with the QJ72BR15; 
they must be purchased separately. 
* Terminal resistor (75 

Ω

y

 A6RCON-R75 

 

Summary of Contents for QJ72BR15

Page 1: ...you for purchasing the Mitsubishi programmable controller MELSEC Q Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MODEL NET H...

Page 2: ...autions on the programmable controller system refer to the CPU User s Manual In this manual the safety instructions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause hazardo...

Page 3: ...specified torque range Undertightening can cause a drop short circuit or malfunction Overtightening can cause a drop short circuit or malfunction due to damage to the screw or module z Completely turn...

Page 4: ...r fasten them using a clamp If the cables are not placed in a duct or not fastened with a clamp their positions may become unstable and may move or they may be pulled inadvertently This may damage the...

Page 5: ...05 IB NA 0800145 F Partial correction Compliance with the EMC Directive and the Low Voltage Directive Chapter 4 Mar 2006 IB NA 0800145 G Partial correction Chapter 2 4 Mar 2007 IB NA 0800145 H Change...

Page 6: ...A 5 CONTENTS 1 Overview 1 2 Performance Specifications 2 3 Handling 6 3 1 Module Handling Precautions 6 4 Part Identification Names 7 5 Wiring 10 6 External Dimensions 11...

Page 7: ...m meeting the requirements of the EMC and Low Voltage Directives when incorporating the Mitsubishi programmable controller EMC and Low Voltage Directives compliant into other machinery or equipment re...

Page 8: ...rm that any of the following products is enclosed Model name Part name Quantity QJ72LP25 25 QJ72LP25 25 MELSECNET H Network Module optical loop type 1 QJ72LP25G QJ72LP25G MELSECNET H Network Module op...

Page 9: ...B 8 2 LW 2000 bytes Maximum I O points per remote I O station X Y 4096 points If the X Y numbers are duplicate only one side is taken into consideration Communication speed 25Mbps 10Mbps selected with...

Page 10: ...determined according to the type of cable Refer to the Q Corresponding MELSECNET H Network System Reference Manual Remote I O network for details 4 Specialized skill and specific tools are required to...

Page 11: ...I O station X Y 4096 points If the X Y numbers are duplicate only one side is taken into consideration Communication speed 10 Mbps Communication method Token bus Synchronization method Frame synchron...

Page 12: ...g determined according to the type of cable and number of stations Refer to the Q Corresponding MELSECNET H Network System Reference Manual Remote I O network for details 4 When creating a multiplexed...

Page 13: ...d torque range Undertightening can cause a drop short circuit or malfunction Overtightening can cause a drop short circuit or malfunction due to damage to the screw or module z Completely turn off the...

Page 14: ...n 1 LED indicator section 1 in this chapter 2 RS 232 connector 5 RESET switch 1 3 Station number setting switches 2 a in this chapter 6 Coaxial connector 3 in this chapter 4 Mode setting switch 2 b in...

Page 15: ...QJ72LP25 25 and QJ72BR15 whose first five digits of the serial number is 02112 or later 2 When a remote I O module is used in a redundant power supply system the REM LED and ERR LED indicate errors as...

Page 16: ...return test 2 Internal self return test 3 Hardware test 10Mbps used 4 Online 5 Self return test 6 Internal self return test 7 Hardware test 25Mbps used 8 to F Prohibited 2 QJ72LP25G QJ72BR15 Setting...

Page 17: ...o malfunction because of faulty cable connections z When disconnecting a communication cable do not pull it by holding the cable part To disconnect the cable hold its connector that is plugged into th...

Page 18: ...11 6 External Dimensions 1 QJ72LP25 25 QJ72LP25G 90 3 54 1 27 4 98 3 86 1 08 4 23 0 91 0 16 1 Please contact your nearest Mitsubishi Electric System Service Corporation for detail Unit mm in...

Page 19: ...12 2 QJ72BR15 90 3 54 55 27 4 98 3 86 0 5 8 3 7 2 0 5 8 3 7 2 0 8 D 5 C 4 9 1 RS 232 MODE RESET Q J72B R15 STATION X10 X1 NO 2 17 1 08 Unit mm in...

Page 20: ...s Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 South Africa Circuit Breaker Industri...

Reviews: