background image

 

A-6

 

About Manuals 

 

The following manuals are also related to this product. 
In necessary, order them by quoting the details in the tables below. 

 

Related Manuals 

 

Manual name 

Manual No. 

(Model code) 

Q corresponding MELSECNET/H Network System 
Reference Manual (Remote I/O network) 

SH-080124 

(13JF96) 

Q corresponding MELSECNET/H Network System 
Reference Manual (PLC to PLC network) 

SH-080049 

(13JF92) 

 
 
 
Compliance with the EMC and Low Voltage Directives 

(1) For programmable controller system 

To configure a system meeting the requirements of the EMC and Low 
Voltage Directives when incorporating the Mitsubishi programmable 
controller (EMC and Low Voltage Directives compliant) into other 
machinery or equipment, refer to Chapter 9 "EMC AND LOW VOLTAGE 
DIRECTIVES" of the QCPU User's Manual (Hardware Design, 
Maintenance and Inspection). 
The CE mark, indicating compliance with the EMC and Low Voltage 
Directives, is printed on the rating plate of the programmable controller. 

 

(2) For the product 

For the compliance of this product with the EMC and Low Voltage 
Directives, refer to Section 9.1.3 "Cables" in Chapter 9 "EMC AND LOW 
VOLTAGE DIRECTIVES" of the QCPU User's Manual (Hardware Design, 
Maintenance and Inspection). 

 

 

Summary of Contents for QJ72BR15

Page 1: ...you for purchasing the Mitsubishi programmable controller MELSEC Q Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MODEL NET H...

Page 2: ...autions on the programmable controller system refer to the CPU User s Manual In this manual the safety instructions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause hazardo...

Page 3: ...specified torque range Undertightening can cause a drop short circuit or malfunction Overtightening can cause a drop short circuit or malfunction due to damage to the screw or module z Completely turn...

Page 4: ...r fasten them using a clamp If the cables are not placed in a duct or not fastened with a clamp their positions may become unstable and may move or they may be pulled inadvertently This may damage the...

Page 5: ...05 IB NA 0800145 F Partial correction Compliance with the EMC Directive and the Low Voltage Directive Chapter 4 Mar 2006 IB NA 0800145 G Partial correction Chapter 2 4 Mar 2007 IB NA 0800145 H Change...

Page 6: ...A 5 CONTENTS 1 Overview 1 2 Performance Specifications 2 3 Handling 6 3 1 Module Handling Precautions 6 4 Part Identification Names 7 5 Wiring 10 6 External Dimensions 11...

Page 7: ...m meeting the requirements of the EMC and Low Voltage Directives when incorporating the Mitsubishi programmable controller EMC and Low Voltage Directives compliant into other machinery or equipment re...

Page 8: ...rm that any of the following products is enclosed Model name Part name Quantity QJ72LP25 25 QJ72LP25 25 MELSECNET H Network Module optical loop type 1 QJ72LP25G QJ72LP25G MELSECNET H Network Module op...

Page 9: ...B 8 2 LW 2000 bytes Maximum I O points per remote I O station X Y 4096 points If the X Y numbers are duplicate only one side is taken into consideration Communication speed 25Mbps 10Mbps selected with...

Page 10: ...determined according to the type of cable Refer to the Q Corresponding MELSECNET H Network System Reference Manual Remote I O network for details 4 Specialized skill and specific tools are required to...

Page 11: ...I O station X Y 4096 points If the X Y numbers are duplicate only one side is taken into consideration Communication speed 10 Mbps Communication method Token bus Synchronization method Frame synchron...

Page 12: ...g determined according to the type of cable and number of stations Refer to the Q Corresponding MELSECNET H Network System Reference Manual Remote I O network for details 4 When creating a multiplexed...

Page 13: ...d torque range Undertightening can cause a drop short circuit or malfunction Overtightening can cause a drop short circuit or malfunction due to damage to the screw or module z Completely turn off the...

Page 14: ...n 1 LED indicator section 1 in this chapter 2 RS 232 connector 5 RESET switch 1 3 Station number setting switches 2 a in this chapter 6 Coaxial connector 3 in this chapter 4 Mode setting switch 2 b in...

Page 15: ...QJ72LP25 25 and QJ72BR15 whose first five digits of the serial number is 02112 or later 2 When a remote I O module is used in a redundant power supply system the REM LED and ERR LED indicate errors as...

Page 16: ...return test 2 Internal self return test 3 Hardware test 10Mbps used 4 Online 5 Self return test 6 Internal self return test 7 Hardware test 25Mbps used 8 to F Prohibited 2 QJ72LP25G QJ72BR15 Setting...

Page 17: ...o malfunction because of faulty cable connections z When disconnecting a communication cable do not pull it by holding the cable part To disconnect the cable hold its connector that is plugged into th...

Page 18: ...11 6 External Dimensions 1 QJ72LP25 25 QJ72LP25G 90 3 54 1 27 4 98 3 86 1 08 4 23 0 91 0 16 1 Please contact your nearest Mitsubishi Electric System Service Corporation for detail Unit mm in...

Page 19: ...12 2 QJ72BR15 90 3 54 55 27 4 98 3 86 0 5 8 3 7 2 0 5 8 3 7 2 0 8 D 5 C 4 9 1 RS 232 MODE RESET Q J72B R15 STATION X10 X1 NO 2 17 1 08 Unit mm in...

Page 20: ...s Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 South Africa Circuit Breaker Industri...

Reviews: