7-9-4 Adjustment of the upper thread heater
The upper heater must be an angle of approx. 90
°
to the thread positioned by the thread
wiper.
The fully extended heater must have a clearance of approx. 1 mm to the clamped material.
The fully extended heater must touch on the thread positioned by the thread wiper with a
slight pressure.
To adjust the position of the upper thread heater
(1) Extend the heater (NO. ) manually.
(2) Loosen the screws (NO. ) and the screws (NO. ).
(3) Adjust the heater vertically and horizontally.
(4) tighten the screws (NO. and )and the screws.
(5) After this adjustment, check the sensor I7(NO. ) of the heater cylinder (NO. ) should be
ON and the sensor I6(NO. ) should be OFF at the normal position.
33
Summary of Contents for PLK-E1008H
Page 19: ...14...
Page 25: ...20 20...
Page 52: ...47...