OC196A-3
FEATURES
2
1. COMPACT DESIGN
The PK series models have been downsized and now require such minimal wall space that they can even be installed
above windows. For the PK12, 11-13/16in of wall space between the ceiling and the window allows “above window”
installation. (13-3/8in for the PK24/30/36)
2. AUTO FLAP SHUTTER
With a simple flick of the OFF switch the air outlet will be closed off with a shutter. The shutter also functions as a flap
during operation to adjust the air flow angle, with “Auto Angle 1” securing a comfortable air flow.
3. INSTALLATION : FAST AND ENDLESSLY ADAPTABLE
(1) Multi-directional piping
Multi directional drain and refrigerant piping radically improves flexibility in selecting installation layouts.
PK12 drain piping can be installed in 5 directions, while PK18/24/30/36 models boast refrigerant piping in 4 directions
and drain piping 2 directions.
(2) Back plate installation guide
The back plate installation guide gives clear instructions on installation positions. The enlarged back plate secures the
unit firmly to the wall, while the support piece which lifts the unit makes left side piping work much easier.
(3) Easily removable filter
The presence of thumbscrews on the filters means that the filters can be quickly and smoothly removed.
FILTER
CHECK MODE
TEST RUN
TIMER OFF TIMER
CHECK SET TEMP.
CLOCK AUTO AUTO
START STOP
SWING
FAN
SPEED
AUTO
RETURN
Indoor unit
Models
Cooling capacity
SEER
PK12FK, PK12FK
1
12,500 Btu/h
11.5
PK18FK, PK18FK
1
, PK18FK
2
18,500 Btu/h
11.3
PK24FK, PK24FK
1
, PK24FK
2
24,000 Btu/h
10.6
PK30FK, PK30FK
1
, PK30FK
2
30,000 Btu/h
10.7
PK36FK, PK36FK
1
, PK36FK
2
34,200 Btu/h
10.2
MITSUBISHI ELECTRIC
ON
DRY
COOL
FAN
CHECK
SET TEMP
TIMER OFF
AUTO STOP
AUTO START
F
HR
F
LOW HIGH
AUTO RETURN
CHECK TEST RUN
POWER
ON/OFF
MODE SELECT
SET
TEMPERATURE
FAN
COOL/DRY
COOLER
WARMER
TIMER
MODE
HOURS
FAN SPEED LOW/HIOGH
AIR
DISCHARGE
UP/DOWN
SWING
STOP
CHECK
TEST RUN
•CENTRALLY CONTROLLED•
(PK12/18/24/30/36FK)
PK12/18/24/30/36FK
1
PK18/24/30/36FK
2
Remote controller
(
)