275
APPENDICES
A
Appendix 3 Details of R
emote Buffer
Memory Addresses
(13)Module-based monitoring data (address: 0620
H
to 0621
H
, 0640
H
to 0641
H
)
Address
Name
Description
Default
CH1
CH2
0620
H
0640
H
Operation mode
• This area stores the present operation mode.
• The following shows the range of values which can be stored.
0: Normal Mode
1: Frequency Measurement Mode
2: Rotation Speed Measurement Mode
3: Pulse Measurement Mode
4: PWM Output Mode
• When Initial data setting request flag (RY9) is turned off then on, the value in
this area is cleared.
0
0621
H
0641
H
Selected counter
function
• This area stores the counter function currently valid.
• The following shows the range of values which can be stored.
0: Count Disable Function
1: Latch Counter Function
2: Sampling Counter Function
3: Periodic Pulse Counter Function
4: Count disable/Preset/replace Function
5: Latch counter/Preset/replace Function
• When Initial data setting request flag (RY9) is turned off then on, the value in
this area is cleared.
0