background image

5.  Drainage piping work .........................................................................................7

6.  Electrical work ...................................................................................................8

7.  Test run ............................................................................................................13

8.  Easy maintenance function (Option) ...............................................................15

► Before installing the unit, make sure you read all the “Safety 

precautions”.

► Please report to your supply authority or obtain their consent before 

connecting this equipment to the power supply system.

 Warning:

Describes precautions that must be observed to prevent danger of injury or 

death to the user.

 Caution:

Describes precautions that must be observed to prevent damage to the unit.

Contents

 Warning:

•  Ask a dealer or an authorized technician to install the unit.

•  For installation work, follow the instructions in the Installation Manual and use 

tools and pipe components specifically made for use with refrigerant specified 

in the outdoor unit installation manual.

•  The unit must be installed according to the instructions in order to minimize 

the  risk  of  damage  from  earthquakes,  typhoons,  or  strong  winds. An 

incorrectly installed unit may fall down and cause damage or injuries.

•  The  unit  must  be  securely  installed  on  a  structure  that  can  sustain  its 

weight. 

•  If the air conditioner is installed in a small room, measures must be taken to 

prevent the refrigerant concentration in the room from exceeding the safety 

limit in the event of refrigerant leakage. Should the refrigerant leak and cause 

the concentration limit to be exceeded, hazards due to lack of oxygen in the 

room may result.

•  Ventilate the room if refrigerant leaks during operation. If refrigerant comes 

into contact with a flame, poisonous gases will be released.

•  All electric work must be performed by a qualified technician according to 

local regulations and the instructions given in this manual. 

•  Use only specified cables for wiring. The wiring connections must be made 

securely with no tension applied on the terminal connections. Also, never 

splice the cables for wiring (unless otherwise indicated in this document).

  Failure to observe these instructions may result in overheating or a fire.

•  The terminal block cover panel of the unit must be firmly attached.

•  Use only accessories authorized by Mitsubishi Electric and ask a dealer or 

an authorized technician to install them.

•  The user should never attempt to repair the unit or transfer it to another 

location.

•  After installation has been completed, check for refrigerant leaks. If refrigerant 

leaks into the room and comes into contact with the flame of a heater or 

portable cooking range, poisonous gases will be released.

•  When installing or relocating, or servicing the air conditioner, use only the 

specified refrigerant (R410A) to charge the refrigerant lines. Do not mix it 

with any other refrigerant and do not allow air to remain in the lines.

  If air is mixed with the refrigerant, then it can be the cause of abnormal high 

pressure in the refrigerant line, and may result in an explosion and other 

hazards.

  The use of any refrigerant other than that specified for the system will cause 

mechanical failure or system malfunction or unit breakdown. In the worst 

case, this could lead to a serious impediment to securing product safety.

1.1.  Before installation (Environment)

 Caution:

•  Do not use the unit in an unusual environment. If the air conditioner is 

installed in areas exposed to steam, volatile oil (including machine oil), or 

sulfuric gas, areas exposed to high salt content such as the seaside, the 

performance can be significantly reduced and the internal parts can be 

damaged.

•  Do not install the unit where combustible gases may leak, be produced, 

flow, or accumulate. If combustible gas accumulates around the unit, fire 

or explosion may result.

•  Do not keep food, plants, caged pets, artwork, or precision instruments in 

the direct airflow of the indoor unit or too close to the unit as these items 

can be damaged by temperature changes or dripping water.

•  When the room humidity exceeds 80% or when the drainpipe is clogged, 

water may drip from the indoor unit. Do not install the indoor unit where 

such dripping can cause damage.

•  When installing the unit in a hospital or communications office, be 

prepared for noise and electronic interference. Inverters, home appliances, 

high-frequency medical equipment, and radio communications equipment 

can cause the air conditioner to malfunction or breakdown. The air 

conditioner may also affect medical equipment, disturbing medical care, 

and communications equipment, harming the screen display quality.

1.  Safety precautions

After installation work has been completed, explain the “Safety precautions,” use, 

and maintenance of the unit to the customer according to the information in the 

Operation Manual and perform the test run to ensure normal operation. Both the 

Installation Manual and Operation Manual must be given to the user for keeping. 

These manuals must be passed on to subsequent users.

 : Indicates a part which must be grounded.

 Warning:

Carefully read the labels affixed to the main unit.

1.4.  Before starting the test run

 Caution:

•  Turn on the main power switch more than 12 hours before starting operation. 

Starting operation just after turning on the power switch can severely damage 

the internal parts.

•  Before starting operation, check that all panels, guards and other protective 

parts are correctly installed. Rotating, hot, or high voltage parts can cause 

injuries.

•  Do not operate the air conditioner without the air filter set in place. If the air 

filter is not installed, dust may accumulate and breakdown may result.

•  Do not touch any switch with wet hands. Electric shock may result.

•  Do not touch the refrigerant pipes with bare hands during operation.

•  After stopping operation, be sure to wait at least five minutes before turning 

off  the  main  power  switch.  Otherwise,  water  leakage  or  breakdown  may 

result.

1.3.  Before electric work

 Caution:

•  Be sure to install molded case circuit brakers. If not installed, electric shock 

may result.

•  For the power lines, use standard cables of sufficient capacity. Otherwise, a 

short circuit, overheating, or fire may result.

•  When installing the power lines, do not apply tension to the cables.

•  Be sure to ground the unit. If the unit is not properly grounded, electric shock 

may result.

•  Use  circuit  breakers  (ground  fault  interrupter,  isolating  switch  (+B  fuse), 

and molded case circuit breaker) with the specified capacity. If the circuit 

breaker capacity is larger than the specified capacity, breakdown or fire may 

result.

1.2.  Before installation or relocation

 Caution:

•  Be  extremely  careful  when  transporting  the  units.  Two  or  more  persons 

are needed to handle the unit as it weighs 20 kg or more. Do not grasp the 

packaging bands. Wear protective gloves as you can injure your hands on 

the fins or other parts.

•  Be sure to safely dispose of the packaging materials. Packaging materials, 

such as nails and other metal or wooden parts may cause stabs or other 

injuries.

•  Thermal insulation of the refrigerant pipe is necessary to prevent condensation. 

If the refrigerant pipe is not properly insulated, condensation will be formed.

•  Place thermal insulation on the pipes to prevent condensation. If the 

drainpipe is installed incorrectly, water leakage and damage to the ceiling, 

floor, furniture, or other possessions may result.

•  Do not clean the air conditioner unit with water. Electric shock may result.

•  Tighten all flare nuts to specification using a torque wrench. If tightened 

too much, the flare nut can break after an extended period.

1.  Safety precautions .............................................................................................2

2.  Installation location ............................................................................................3

3.  Installing the indoor unit ....................................................................................3

4.  Installing the refrigerant piping ..........................................................................6

Note:

The phrase “Wired remote controller” in this installation manual refers to the PAR-21MAA.

If you need any information for the other remote controller, please refer to either the installation manual or initial setting manual which are 

included in these boxes.

RG79D479H02_en.indd   2

2012/10/09 (火)   午前 11:37:48

Summary of Contents for Mr.Slim PKA-RP35HAL

Page 1: ...begint MANUALE DI INSTALLAZIONE Per un uso sicuro e corretto prima di installare il condizionatore d aria leggere attentamente il presente manuale ed il manuale d installazione dell unit esterna MANU...

Page 2: ...changes or dripping water When the room humidity exceeds 80 or when the drainpipe is clogged water may drip from the indoor unit Do not install the indoor unit where such dripping can cause damage Whe...

Page 3: ...am to the left The hole should incline so that the outside opening is lower than the inside opening Insert a sleeve with a 75 mm diameter and purchased locally through the hole A Sleeve B Hole C Indoo...

Page 4: ...rking on the mount board as a reference when adjusting the length of the embedded cooling pipe During construction give the length of the extruding pipes etc some leeway A Mount board 1 B Reference ma...

Page 5: ...ve the indoor unit to the left and right and verify that the indoor unit is hung securely 5 Fasten by pushing the bottom part of the indoor unit onto the mount board 1 Fig 3 10 Check that the knobs on...

Page 6: ...6 35 17 14 18 12 7 28 49 61 PKA RP HAL Fig 4 3 B A 4 2 Indoor unit Refrigerant and Drainage Piping Sizes Item Model PKA RP35 RP50HAL Refrigerant piping Liquid OD 6 35 1 4 Gas OD 12 7 1 2 Drainage pip...

Page 7: ...r H Drainage ditch I 5 cm or less between the end of drain pipe and the ground J Drain hose K Soft PVC hose Inside diameter 15 mm or Hard PVC pipe VP 16 Bond with PVC type adhesive Preparing left and...

Page 8: ...te control cord J Indoor outdoor connection cord K Hook L Ground wire connection portion Warning Never splice the power cable or the indoor outdoor connection cable otherwise it may result in a smoke...

Page 9: ...ize must comply with the applicable local and national code 2 Power supply cords and Indoor unit Outdoor unit connecting cords shall not be lighter than polychloroprene sheathed flexible cord Design 2...

Page 10: ...door unit DIP switch settings when using separate indoor unit outdoor unit power supplies only ON OFF 1 2 SW8 3 There are three types of labels labels A B and C Affix the appropriate labels to the uni...

Page 11: ...he min button twice continuously Pair No 0 blinks 3 Press the temp button to set the pair number you want to set 4 Press the SET button with something sharp at the end Set pair number is lighted for t...

Page 12: ...ly 6 Complete function selection Direct the wireless remote controller toward the sensor of the indoor unit and press the button E Note Whenever changes are made to the function settings after install...

Page 13: ...mode then check whether warm air is blown out from the unit 5 Press the FAN button and check whether fan speed changes 6 Press the VANE button and check whether the auto vane operates properly 7 Press...

Page 14: ...U6 Compressor overcurrent interruption Abnormal of power module 10 U7 Abnormality of super heat due to low discharge temperature 11 U9 UH Abnormality such as overvoltage or voltage shortage and abnor...

Page 15: ...ng phenomena takes place No signals from the remote controller are accepted OPE lamp is blinking The buzzer makes a short pipng sound Note Operation is not possible for about 30 seconds after cancella...

Page 16: ...ime displayed is the number of hours the filter has been used since the filter reset was performed 4 Press the FILTER button 5 The data is displayed in C Airflow temperature display example Flashing W...

Page 17: ...oducts Directive 2009 125 EC This product is designed and intended for use in the residential commercial and light industrial environment The product at hand is based on the following EU regulations R...