7. Wiring Diagram and Block Diagram
7.1 Wiring Diagram
(1) Current fuse ....................Overcurrent flow caused by deterioration in electrical parts or other problems
turns the power source to OFF.
<Current setting: 2A>
(2) Motor protector ................The compressor stops operating if the room temperature exceeds 35°C.
(Overload relay)
The compressor will also shut down when malfunctions or other problems
cause the current flow to exceed 5.3A.
(3) Control circuitry ...............The room temperature thermister senses temperature below about 0°C, and
shuts down the compressor.
(4) Thermal fuse ...................When blower motor temperature exceeds 133°C due to blower locking or other
malfunctions, blower operation shuts down.