Chapter 8 Adjustment
8–32
No.
Abbrev.
Parameter name
Explanation
Setting range
bit
Meaning when "0" is set
Meaning when "1" is set
0
1
2
3
nfd
Set the filter depth for the notch filter (SV038: FHz).
The control is stabilized by making the filter shallower.
Setting value
0
2
4
6
8
A
C
E
Depth (dB)
∞
−
18.1
−
12.0
−
8.5
−
6.0
−
4.1
−
2.5
−
1.2
4
5
6
7
8
9
10
11
12
13
14
15
SV033
SSF2
Special servo
function selection 2
Set "0" in bits with no particular description.
CNC servo monitor MAX current display data changeover
bit
Meaning when "0" is set
Meaning when "1" is set
0
mon Current command monitor value
Current FB monitor value
1
2
3
4
dac1 D/A output ch.1 overflow setting
D/A output ch.1 clamp setting
5
6
daf1 D/A output ch.1 no filter
D/A output ch.1 filter setting
7
8
9
10
11
12
13
14
15
SV034
SSF3
Special servo
function selection 3
Set "0" in bits with no particular description.