2. Replacement of Major Parts
2-1. CLEANING ARM, FELT RING
SET POSITION :
Normal
(Removal)
1. Release the two catches (
a
) of the CLEANING ARM
shown in the Fig. 2-1 to remove the CLEANING ARM.
2. Release the two catches (
b
) of the CLEANING ARM
shown in the Fig. 2-1 to remove the FELT RING.
(Installation)
1. Install the FELT RING shown in the Fig. 2-1 to the
CLEANING ARM.
2. Install the CLEANING ARM shown in the Fig. 2-1.
2-2. STAY PLATE
SET POSITION :
Normal
(Removal)
1. Remove the two screws (
a
) fastening the STAY
PLATE shown in the Fig. 2-2 to remove the STAY
PLATE.
(Installation)
1. Install the STAY PLATE shown in the Fig. 2-2.