FX
2N
/FX
2NC
FUNCTION EXPANSION MEMORY
HARDWARE MANUAL
JY997D00401A
This manual contains text, diagrams and explanations which will guide the reader in the correct installation
and operation of the FX
2N
/FX
2NC
Function Expansion Memory. It should be read and understood before
attempting to install or use the unit. Further information can be found in the FX
2N
or FX
2NC
series PLC
hardware manuals.
Guidelines for the safety of the user and protection of the FX
2N
/FX
2NC
Function
Expansion Memory
•
If in doubt at any stage during the installation of the FX
2N
/FX
2NC
Function Expansion Memory always
consult a professional electrical engineer who is qualified and trained to the local and national standards.
If in doubt about the operation or use of the FX
2N
/FX
2NC
Function Expansion Memory please consult the
nearest Mitsubishi Electric distributor.
•
Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage
that may arise as a result of the installation or use of this equipment.
•
All examples and diagrams shown in this manual are intended only as an aid to understanding the
text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual use of the
product based on these illustrative examples.
•
Owing to the very great variety in possible application of this equipment, you must satisfy yourself as
to its suitability for your specific application.
Note’s on the symbology used in this manual
At various times through out this manual certain symbols will be used to highlight points of information
which are intended to ensure the user’s personal safety and protect the integrity of the equipment.
Whenever any of the following symbols are encountered, its associated note must be read and
understood. Each of the symbols used will now be listed with a brief description of its meaning.
Hardware warnings
1) Indicates that the identified danger WILL cause physical and property damage.
2) Indicates that the identified danger could POSSIBLY cause physical and property damage.
Associated Manuals
¤
: Indispensable manual
¡
: Either manual is necessary
1. Product Outline
1.1 Features
FX
2N
-ROM-E1 and FX
2NC
-ROM-CE1 are optional memories for the FX
2N
or FX
2NC
Series PLC to add
external ROM instruction.
In the products, system programs to add external ROM instruction, EXTR (FNC 180), and the EEPROM
memory which can be used as a PLC program area are built in.
1.2 Programming Tools Applicable for EXTR (FNC 180) Instruction
Manual name
Manual number
Description
¤
FX
1S
/FX
1N
/FX
2N
/FX
2NC
Programming Manual
II
JY992D88101
(sent separately)
Explains the instructions in the FX
1S
/FX
1N
/
FX
2N
/FX
2NC
Series PLC.
¡
FX
2N
Hardware Manual
JY992D66301
(included with product)
Describes the contents related to the hardware
such as specification, wiring and mounting of
the FX
2N
Series PLC.
¡
FX
2NC
Hardware Manual
JY992D76401
(included with product)
Describes the contents related to the hardware
such as specification, wiring and mounting of
the FX
2NC
Series PLC.
Model name
Version
GX Developer
SW7 or later
FX-PCS/WIN-E
3.10 or later
FX-10P-E
4.10 or later
FX-20P-E (FX-20P-MFXD-E)
5.10 or later
2. Specifications
3. Installation and Operation
• Don’t attach/remove the memory cassette or memory board before turning off the power.
Attaching/removing it while the power is on may damage its contents or element.
• Don’t touch the memory cassette or memory board before discharging static from the body of
the user. When transporting, make sure to wrap it in a static-free sheet to prevent damaging its
contents or element.
3.1 Installation of FX
2N
-ROM-E1
1) Turn off the power of the PLC and remove the cover "a)".
2) Install FX
2N
-ROM-E1 "b)" to the port on the main unit.
3) Put back the cover "a)".
3.2 Installation of FX
2NC
-ROM-CE1
1) Turn off the power of the PLC and remove the cover "a)".
2) Install FX
2NC
-ROM-CE1 "b)" to the port on the main unit.
3) Place cover "c)", included in the memory board product box, onto the PLC.
Model name
FX
2N
-ROM-E1 function expansion
memory cassette
FX
2NC
-ROM-CE1 function expansion
memory board
Applicable PLC
FX
2N
PLC version 3.00 or later
(Serial number 15**** or later)
FX
2NC
PLC version 3.00 or later
(Serial number 15**** or later)
If installed in PLC earlier than version 3.00, only 16k-step user program memory
and clock function can be used.
Built-in
functions
System
memory
Equipped with functions K10 to K13 of the EXTR (FNC 180) instruction
• K10: Inverter operation monitoring
• K11: Inverter operation control
• K12: Read of inverter parameter
• K13: Write of inverter parameter
User
program
memory
• Memory capacity: 16k steps (can be set to 2k, 4k or 8k steps also)
• Memory type: EEPROM
• Allowable number of write: Approx. 10k times (memory protect switch provided)
Clock
function
Not provided (clock is built in PLC)
• Year 1980 to 2079
• Year display in 2 or 4 digits
• Monthly difference of
±
45 sec. (at 25
°
C)
7
2
4 5
6
1
3
0
1 6
1 1
1 5
1 4
1 7
1 0
1 2 1
3
1 4
1 7
1 5
1 0
1 2 1
3
7
2
4 5
6
1
3
0
1 6
1 1
O U
T
I N
L
2 4 +
X 1
X 3
7
Y 1
Y 3
C O
M 2 Y
5
Y 7
C O
Y 1 3
C O
M 4Y
1
Y 0
Y 2
Y 4
Y 6
Y 1 2
Y 1 4
N
a )
F X 2 N m a i n u n i t
M e m o r y p r o t e c t
s w i t c h
b )
F X
2 N C
m a i n u n i t
M e m o r y p r o t e c t s w i t c h
b )
c )
a )
3.3 Operation
•
The program error may flash when used for the first time because the EEPROM (user program memory) is
not initialized. In the personal computer or FX-20P (off-line mode), transfer and write a program in that
status. In the FX-10P or FX-20P (online mode), execute all NOP write to erase the contents.
•
After writing a program, make sure to verify.
•
Set the memory protect switch to OFF before writing a program. During normal operation, it is recommended
to set it to ON to prevent erroneous write.
•
When installed in the FX
2N
or FX
2NC
Series PLC version 3.00 or later, the EXTR (FNC 180) instruction and
the 16k-step EEPROM and clock function can be used.
If installed in the FX
2N
or FX
2NC
Series PLC earlier than version 3.00, only the 16k-step EEPROM and clock
function can be used.
4. Inverter Communication Function
• When handling the PLC or inverter, follow the notices indicated in each manual which is
included with the main unit in order to avoid electric shock, fire, a damage or an accident.
• Make sure to perform class D grounding of the ground terminal of communication equipment for
the PLC together with that of the PLC main unit. Ground the shield of a shielded cable at one
point on the PLC. Do not, however, ground at the same point as high voltage line. If grounding is
imperfect, effects of noise or surge induction takes place, and it may cause a communication
error or erroneous operation.
• The signal cables must not be laid near or bundled with the main circuit lines, high voltage power
cables or load carrying wires. Otherwise effects of noise or surge induction are likely to take
place, and it may cause a communication error or erroneous operation.
Keep a safe distance of more than 100mm (3.94") from these wires.
4.1 Outline of Functions and System Configuration
When using K10 to K13 of the EXTR (FNC 180) instruction, operation monitoring, control value write or
parameter monitoring and change in the A500/E500/S500 (with RS-485 communication function) Series
MITSUBISHI TRANSISTORIZED INVERTER can be performed.
The details of programming and setting can be found in the Programming Manual
II
, JY992D88101.
•
Total extension distance
•
Connecting with one inverter
PLC
Using interface
Extension distance
FX
2N
FX
2N
-485-BD
Maximum 50m (164')
FX
2N
-CNV-BD + FX
0N
-485ADP
Maximum 500m (1640')
FX
2NC
FX
0N
-485ADP
1) PLC
FX
2N
,FX
2NC
(version 3.00 or later)
RS-485 communication module
[FX
2N
]
FX
2N
-485-BD
FX
0N
- FX
2N
-CNV-BD
[FX
2NC
]
FX
0N
-485ADP
S500 (with RS-485
communication function)
E500
PU (RS-485) connector
2) Inverter
A500
PU connector
3) 10 BASE-T cable
4) Twisted pair cable
A500
Optional connection
Termination resistors are
needed on both ends of 1)
and 2).
.
.
.
FR-A5NR