background image

FX

2N

/FX

2NC

 FUNCTION EXPANSION MEMORY

HARDWARE MANUAL

JY997D00401A

This manual contains text, diagrams and explanations which will guide the reader in the correct installation
and operation of the FX

2N

/FX

2NC

 Function Expansion Memory. It should be read and understood before

attempting to install or use the unit. Further information can be found in the FX

2N

 or FX

2NC

 series PLC

hardware manuals.

Guidelines for the safety of the user and protection of the FX

2N

/FX

2NC

 Function 

Expansion Memory

If in doubt at any stage during the installation of the FX

2N

/FX

2NC

 Function Expansion Memory always

consult a professional electrical engineer who is qualified and trained to the local and national standards.
If in doubt about the operation or use of the FX

2N

/FX

2NC

 Function Expansion Memory please consult the

nearest Mitsubishi Electric distributor. 

Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage
that may arise as a result of the installation or use of this equipment. 

All examples and diagrams shown in this manual are intended only as an aid to understanding the
text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual use of the
product based on these illustrative examples. 

Owing to the very great variety in possible application of this equipment, you must satisfy yourself as
to its suitability for your specific application. 

Note’s on the symbology used in this manual

At various times through out this manual certain symbols will be used to highlight points of information
which are intended to ensure the user’s personal safety and protect the integrity of the equipment.
Whenever any of the following symbols are encountered, its associated note must be read and
understood. Each of the symbols used will now be listed with a brief description of its meaning.

Hardware warnings

1) Indicates that the identified danger WILL cause physical and property damage.

2) Indicates that the identified danger could POSSIBLY cause physical and property damage.

Associated Manuals

¤

: Indispensable manual

¡

: Either manual is necessary

1. Product Outline

1.1 Features

FX

2N

-ROM-E1 and FX

2NC

-ROM-CE1 are optional memories for the FX

2N

 or FX

2NC

 Series PLC to add

external ROM instruction.
In the products, system programs to add external ROM instruction, EXTR (FNC 180), and the EEPROM
memory which can be used as a PLC program area are built in.

1.2 Programming Tools Applicable for EXTR (FNC 180) Instruction

Manual name

Manual number

Description

¤

FX

1S

/FX

1N

/FX

2N

/FX

2NC

Programming Manual 

II

JY992D88101

(sent separately)

Explains the instructions in the FX

1S

/FX

1N

/

FX

2N

/FX

2NC

 Series PLC.

¡

FX

2N

 Hardware Manual

JY992D66301

(included with product)

Describes the contents related to the hardware 
such as specification, wiring and mounting of 
the FX

2N

 Series PLC.

¡

FX

2NC

 Hardware Manual

JY992D76401

(included with product)

Describes the contents related to the hardware 
such as specification, wiring and mounting of 
the FX

2NC

 Series PLC.

Model name

Version

GX Developer

SW7 or later

FX-PCS/WIN-E

3.10 or later

FX-10P-E

4.10 or later

FX-20P-E (FX-20P-MFXD-E)

5.10 or later

2. Specifications

3. Installation and Operation

• Don’t attach/remove the memory cassette or memory board before turning off the power.

Attaching/removing it while the power is on may damage its contents or element.

• Don’t touch the memory cassette or memory board before discharging static from the body of

the user. When transporting, make sure to wrap it in a static-free sheet to prevent damaging its
contents or element.

3.1 Installation of FX

2N

-ROM-E1

1) Turn off the power of the PLC and remove the cover "a)".
2) Install FX

2N

-ROM-E1 "b)" to the port on the main unit. 

3) Put back the cover "a)".

3.2 Installation of FX

2NC

-ROM-CE1

1) Turn off the power of the PLC and remove the cover "a)".
2) Install FX

2NC

-ROM-CE1 "b)" to the port on the main unit. 

3) Place cover "c)", included in the memory board product box, onto the PLC.

Model name

FX

2N

-ROM-E1 function expansion 

memory cassette

FX

2NC

-ROM-CE1 function expansion 

memory board

Applicable PLC

FX

2N

 PLC version 3.00 or later

(Serial number 15**** or later)

FX

2NC

 PLC version 3.00 or later

(Serial number 15**** or later)

If installed in PLC earlier than version 3.00, only 16k-step user program memory 
and clock function can be used.

Built-in 
functions

System
memory

Equipped with functions K10 to K13 of the EXTR (FNC 180) instruction

• K10: Inverter operation monitoring
• K11: Inverter operation control
• K12: Read of inverter parameter
• K13: Write of inverter parameter

User
program
memory

• Memory capacity: 16k steps (can be set to 2k, 4k or 8k steps also)
• Memory type: EEPROM
• Allowable number of write: Approx. 10k times (memory protect switch provided)

Clock
function

Not provided (clock is built in PLC)

• Year 1980 to 2079
• Year display in 2 or 4 digits
• Monthly difference of 

±

45 sec. (at 25

°

C)

7

2

4 5

6

1

3

0

1 6

1 1

1 5

1 4

1 7

1 0

1 2 1

3

1 4

1 7

1 5

1 0

1 2 1

3

7

2

4 5

6

1

3

0

1 6

1 1

O U

T

I N

L

2 4 +

X 1

X 3

    7

Y 1

Y 3

C O

M 2 Y

5

Y 7

C O

   

Y 1 3

C O

M 4Y

1  

Y 0

Y 2

Y 4

Y 6

Y 1 2

Y 1 4

N

a )

F X

2 N

  m a i n   u n i t

M e m o r y   p r o t e c t

s w i t c h

b )

F X

2 N C

  m a i n   u n i t

M e m o r y   p r o t e c t   s w i t c h

b )

c )

a )

3.3 Operation

The program error may flash when used for the first time because the EEPROM (user program memory) is
not initialized. In the personal computer or FX-20P (off-line mode), transfer and write a program in that
status. In the FX-10P or FX-20P (online mode), execute all NOP write to erase the contents. 

After writing a program, make sure to verify.

Set the memory protect switch to OFF before writing a program. During normal operation, it is recommended
to set it to ON to prevent erroneous write.

When installed in the FX

2N

 or FX

2NC

 Series PLC version 3.00 or later, the EXTR (FNC 180) instruction and

the 16k-step EEPROM and clock function can be used.
If installed in the FX

2N

 or FX

2NC

 Series PLC earlier than version 3.00, only the 16k-step EEPROM and clock

function can be used.

4. Inverter Communication Function

• When handling the PLC or inverter, follow the notices indicated in each manual which is

included with the main unit in order to avoid electric shock, fire, a damage or an accident.

• Make sure to perform class D grounding of the ground terminal of communication equipment for

the PLC together with that of the PLC main unit. Ground the shield of a shielded cable at one
point on the PLC. Do not, however, ground at the same point as high voltage line. If grounding is
imperfect, effects of noise or surge induction takes place, and it may cause a communication
error or erroneous operation.

• The signal cables must not be laid near or bundled with the main circuit lines, high voltage power

cables or load carrying wires. Otherwise effects of noise or surge induction are likely to take
place, and it may cause a communication error or erroneous operation.
Keep a safe distance of more than 100mm (3.94") from these wires.

4.1 Outline of Functions and System Configuration

When using K10 to K13 of the EXTR (FNC 180) instruction, operation monitoring, control value write or
parameter monitoring and change in the A500/E500/S500 (with RS-485 communication function) Series
MITSUBISHI TRANSISTORIZED INVERTER can be performed.
The details of programming and setting can be found in the Programming Manual 

II

, JY992D88101. 

Total extension distance

Connecting with one inverter

PLC

Using interface

Extension distance

FX

2N

FX

2N

-485-BD

Maximum 50m (164')

FX

2N

-CNV-BD + FX

0N

-485ADP

Maximum 500m (1640')

FX

2NC

FX

0N

-485ADP

1) PLC
     FX

2N

,FX

2NC

     (version 3.00 or later)

RS-485 communication module

[FX

2N

]

   FX

2N

-485-BD

   FX

0N

- FX

2N

-CNV-BD

[FX

2NC

]

   FX

0N

-485ADP

S500 (with RS-485
          communication function)
E500
PU (RS-485) connector

2) Inverter

A500
PU connector

3) 10 BASE-T cable

4) Twisted pair cable

A500
Optional connection

Termination resistors are
needed on both ends of 1)
and 2).

.

.

.

FR-A5NR

Summary of Contents for FX2N-ROM-E1

Page 1: ...nderstood Each of the symbols used will now be listed with a brief description of its meaning Hardware warnings 1 Indicates that the identified danger WILL cause physical and property damage 2 Indicates that the identified danger could POSSIBLY cause physical and property damage Associated Manuals Indispensable manual Either manual is necessary 1 Product Outline 1 1 Features FX2N ROM E1 and FX2NC ...

Page 2: ... 00 or later Serial number 15 or later If installed in PLC earlier than version 3 00 only 16k step user program memory and clock function can be used Built in functions System memory Equipped with functions K10 to K13 of the EXTR FNC 180 instruction K10 Inverter operation monitoring K11 Inverter operation control K12 Read of inverter parameter K13 Write of inverter parameter User program memory Me...

Page 3: ...unding of the ground terminal of communication equipment for the PLC together with that of the PLC main unit Ground the shield of a shielded cable at one point on the PLC Do not however ground at the same point as high voltage line If grounding is imperfect effects of noise or surge induction takes place and it may cause a communication error or erroneous operation The signal cables must not be la...

Page 4: ...istor Station number 0 3 Twisted pair cable Terminal resistor Inverter Station number 1 Inverter Station number 7 FR A5NR FR A5NR FR A5NR Modular jack Viewing from front face of inverter receptacle side ˆ PLC RDA RDB SDA SDB LINK SG 24 24G RDA RDB SDA SDB SG FX0N 485ADP FX2N 485 BD 100Ω 1 4W terminal resistor prepared by the user 110Ω terminal resistor 24V DC 50mA 10 BASE T cable FG Class D ground...

Page 5: ...r 10 BASE T cable Inverter R D B R D A S D A S D B S G PU RS 485 connector 5 4 3 6 1 Distribution terminal 5 4 3 6 1 5 4 3 6 1 5 4 3 6 1 Inverter R D B R D A S D A S D B S G PU RS 485 connector 5 4 3 6 1 Distribution terminal 5 4 3 6 1 5 4 3 6 1 5 4 3 6 1 Inverter R D B R D A S D A S D B S G PU RS 485 connector 5 4 3 6 1 Distribution terminal 5 4 3 6 1 5 4 3 6 1 5 4 3 6 1 100Ω 1 4W terminal resist...

Page 6: ...S 485 connector 5 4 3 6 1 Distribution terminal 5 4 3 6 1 5 4 3 6 1 5 4 3 6 1 100Ω 1 4W terminal resistor prepared by the user attached to the remotest inverter from PLC RS 485 communication module ng terminal cable 0 3mm2 or more A chip for connecting terminal resistor attached to the remotest inverter from PLC Class D grounding R D B R D A S D A S D B S G FR A5NR R D R Inverter R D R Manual numb...

Page 7: ... Install FX2NC ROM CE1 b to the port on the main unit 3 Place cover c included in the memory board product box onto the PLC Model name FX2N ROM E1 function expansion memory cassette FX2NC ROM CE1 function expansion memory board Applicable PLC FX2N PLC version 3 00 or later Serial number 15 or later FX2NC PLC version 3 00 or later Serial number 15 or later If installed in PLC earlier than version 3...

Page 8: ...5 connector Cable Cable conforming to EIA568 such as 10 BASE T cable Terminal resistor On the PLC side 110Ω On the inverter side 100Ω and 1 4W prepared by the user Wiring for FR A5NR Terminal layout Connecting with one inverter Connecting with two or more inverters Maximum 8 inverters Applicable equipment Cable Use the twisted pair cables 0 3mm2 or more 3 pairs Terminal resistor On the PLC side 11...

Reviews: