FX
2N
-20GM
USER’S GUIDE
JY992D77601C
This manual only describes the specifications for FX
2N
-20GM positioning controller.
For complete operation, wiring, mounting and programming instructions please refer to the FX
2N
-10GM,
FX
2N
-20GM HARDWARE PROGRAMMING MANUAL, FX PROGRAMMING MANUAL and FX SERIES
HARDWARE MANUAL.
These manuals should be read and understood before attempting to install or use the unit.
1. Reference manual
Refer to the under mentioned manual for details about product installation, operation and programming.
1) FX
2N
-10GM, FX
2N
-20GM HARDWARE PROGRAMMING MANUAL
The installation, wiring and the instructions of the FX
2N
-10GM and FX
2N
-20GM units are explained.
2) E-20TP OPERATION MANUAL
The operation of the input of the program which uses E-20TP and the monitor and the test is
explained.
3) FX-PCS-KIT-GM-EE SOFTWARE MANUAL
The program is input via the FX-PCS-KIT-GM-EE. The manual explains the operation of the monitor
and test functions.
The manual in 1) is not included with the product. Please request from the shop where the unit was
purchased if required. The manuals in 2) and 3) are included with the product.
2. Outline of the unit
The FX
2N
-20GM positioning controller (hereinafter call FX
2N
-20GM or 20GM) is a pulse chain output unit
that enables the positioning control of a stepping motor or a servo motor via the drive unit.
•
One FX
2N
-20GM can control 2 axes. (Linear interpolation and circular interpolation are available.)
•
Both dedicated positioning language (cod instructions) and sequence language (basic instructions
and application instructions) are available.
•
A pulse generator can be connected to each axis or one pulse generator can be connected to both
axes and switched as required. The manual pulse generators must be an open collector output type.
•
The zero return operation at each start can be omitted with a servo amplifier with the absolute position
(ABS) detection function.
•
The FX
2N
-20GM can be used alone. When an FX
2N
-20GM is connected with an FX
2N
or FX
2NC
series Programmable controller (hereafter call PLC), reading and writing the positioning data can be
done. (When FX
2N
-20GM is connected with the FX
2NC
series PLC, an FX
2NC
-CNV-IF is necessary.)
3. External dimensions
SVRDY-X
LSR
LSF
CLR
RP
FP
PG0
SVEND
SVRDY Y
Y6
Y7
X0
X2
X3
X4
X5
X6
Y0
Y1
Y2
Y3
X1
Y5
X7
Y4
AUTO
MANU
POWER
ERROR-y
CPU-E
PG0
FP
RP
CLR
SVEND
LSR
LSF
DOG
RVS
FWD
ZRN
STOP
START Y
6
7
X0
2
3
X4
5
6
Y0
1
2
3
1
5
7
Y4
BATT
READY-x
ERROR-x
READY-y
DOG
RVS
START X
STOP
ZRN
FWD
90(3.54)
86(3.39)
13
(0.51)
74(2.91)
13
(0.51)
87(3.43)
FX -20GM
2N
Power supply
cable
Din rail width: 35mm
Weight: approx.0.4kg
Dimensions mm(inch)
4. Product composition
4.1 Each part name
The name and description of each part of the FX
2N
-20GM are explained below.
FX -20GM
FWD
ZRN
STOP
START X
RVS
DOG
READY-y
ERROR-x
READY-x
BATT
Y4
7
5
1
3
2
1
Y0
6
5
X4
3
2
X0
7
6
START Y
STOP
ZRN
FWD
RVS
DOG
LSF
LSR
SVEND
CLR
RP
FP
PG0
CPU-E
ERROR-y
POWER
MANU
AUTO
Y4
X7
Y5
X1
Y3
Y2
Y1
Y0
X6
X5
X4
X3
X2
X0
Y7
Y6
SVRDY Y
SVEND
PG0
FP
RP
CLR
LSF
LSR
SVRDY-X
2N
a)
d) e)
c)
b)
l)
f)
j)
i)
h)
g)
k)
r)
q)
n)
o)
m)
p)
s)
h)
l)
Accessories
Power supply cable
FX
2NC
-100MPCB 1
FX
2NC
-100BPCB 1
Connection cable
FX
2N
-GM-5EC 1
a) Battery
b) Operation indicator LED
c) MANU/AUTO switch
d) Connector for programming tool
e) General-purpose I/O display
f) Display for equipment inputs
g) x axis status display
h) Lock to fix extension block of FX
2N
-20GM
i) y axis status display
j) Connector for FX
2N
-20GM extension block
k) Connector for PLC extension block
l) Hook for DIN rail installation
m)Connector for y axis motor amplifier: CON4
n) Connector for x axis motor amplifier: CON3
o) Connector for input equipment: CON2
p) Connector for power supply
q) Connector for general-purpose I/O: CON1
r) Connector for memory board
s) Connector for PLC
4.2 Operation display
The state of FX
2N
-20GM is displayed by LED.
Name of LED
Content
POWER
LED lights when power is supplied. If LED is not lit, check power supply voltage and
current.
READY-X
LED lights when accepting an x-axis instruction. During pulse output or when an error
occurs, the LED is off.
READY-Y
LED lights when accepting a y-axis drive instruction. During pulse output or when an
error occurs, the LED is off.
ERROR-X
LED is lit or blinks when an error occurs in the positioning drive of x axis.
ERROR-Y
LED is lit or blinks when an error occurs in the positioning drive of y axis.
BATT
LED lights when the buttery voltage drops. (Turn Power Supply On)
CPU-E
CPU error. Incompatible system configuration, excess noise, etc.
4.3 I/O connector
The pin array of the I/O connector is as follows.
All terminals with identical names are shorted internally (Ex. COM1-COM1, VIN-VIN, etc.).
Do not wire “•” terminals.
Refer to the FX
2N
-10GM, FX
2N
-20GM HARDWARE PROGRAMMING MANUAL for wiring information.
Y00
Y01
Y02
Y03
Y04
Y05
Y06
Y07
COM1
CON1
X01
X00
X02
X03
X04
X05
X06
X07
COM1
STOP
START
ZRN
FWD
RVS
DOG
LSF
LSR
COM1
CON2
STOP
START
ZRN
FWD
RVS
DOG
LSF
LSR
COM1
COM2
SVRDY
CLR
COM3
FP
VIN
VIN
COM5
ST1
CON3
COM2
SVEND
PG0
COM4
RP
VIN
VIN
COM5
ST2
COM9
VIN
VIN
RP
COM8
PG0
SVEND
ST4
COM6
CON4
ST3
COM9
VIN
VIN
FP
COM7
CLR
SVRDY
COM6
X(axis)
Y(axis)
X(axis)
Y(axis)
4.4 Power supply connector
The power to the FX
2N
-20GM is supplied with the special power supply cable attached to the product.
The ground of the FX
2N
-20GM and the servo amplifier is a common ground. Refer to the FX
2N
-10GM,
FX
2N
-20GM HARDWARE PROGRAMMING MANUAL for detailed wiring instructions.
Red+
Black-
Green
(Ground)
1
3 Ground
2
The FX
2N
-20GM pin numbers
for the power supply connector
are shown below.
FX
2NC
-100MPCB
FX
2N
-20GM
Input block
Output block
Input block
Install a safety circuit
outside of FX
2N
-20GM so
that the entire system may
work safety when the
external power supply
fails.
4.5 I/O extension connector
The FX
2N
-20GM can connect the following extension block.
1) FX
2NC
series extension block
- FX
2NC
-16EX-DS
- FX
2NC
-16EYT-DSS
- FX
2NC
-32EX-DS
- FX
2NC
-32EYT-DSS
- FX
2NC
-16EX-T-DS
- FX
2NC
-16EX-D/UL
- FX
2NC
-16EYT-D/UL
- FX
2NC
-32EX-D/UL
- FX
2NC
-32EYT-D/UL
2) FX
2N
series extension block (FX
2NC
-CNV-IF needs to be used)
- FX
2N
-16EX-ES/UL
- FX
2N
-16EYT-ESS/UL
The increase point is 48 points or less. Assume the turning on rate to be 50% or less simultaneously.
48 points may be added to the system if 50% or less are used simultaneously.
Extension block
FX
2N
-20GM
lock
lock
1. Detach the extension cover on the right side of
the FX
2N
-20GM.
2. Insert the hooks of the extension blocks into
the lock holes, and gently press the units
together.
3. lower the lock to fix the units in place.
4. Attach other extension blocks in the same
manner.
4.6 Connection with PLC
Refer to the FX
2N
-10GM and the FX
2N
-20GM HARDWARE PROGRAMMING MANUAL for details concerning
the system configuration.
The FX
2N
-GM-5EC cable is used to connect the FX
2N
-20GM to an FX
2N
PLC. When a long distance is
required, one FX
2N
-GM-65EC cable can be used per system. To connect to an FX
2NC
PLC, the FX
2NC
-
CNV-IF must be used. Eight blocks may be connected to an FX
2N
PLC and four blocks may be connected
to an FX
2NC
PLC.
FX
2NC
PLC
Main unit
When FX
2NC
PLC is connected
FX
2N
-20GM
FX
2N-
GM-65EC
(optional)
FX
2NC
-16EX
(I/O Extention of main unit
of the PLC)
FX
2N
-20GM
FX
2N
-16EX
(FX
2N
-I/O increase of 20GM)
FX
2N-
GM-5EC
FX
2N-
GM-5EC
FX
2NC
-CNV-IF
4.7 Detaching the memory board
7.8k step of RAM is built into the FX
2N
-20GM. In addition, the optional memory board (FX
2NC
-EEPROM-
16) can be used. (Program capacity is 7.8k steps)
1)
Turn off the power supply to the FX
2N
-
20GM.
2)
Remove the cover of the memory board.
3)
Install the memory board in the connec-
tor.
4)
Replace the cover before turning on the
power supply.
5)
When detaching the memory board,
begin by carefully detaching it from the
bottom side.
Installation
Removal
Industrial automation
Elincom Group
European Union: www.elinco.eu
Russia: www.elinc.ru