![Mitsubishi FR-A846-00023 Instruction Manual Download Page 40](http://html1.mh-extra.com/html/mitsubishi/fr-a846-00023/fr-a846-00023_instruction-manual_1809256040.webp)
Control circuit
39
2
NICHIFU Co.,Ltd.
NOTE
• When using stranded wires without a blade terminal, twist enough to avoid short circuit with a nearby terminals or wires.
• Lead the wires through the holes for wiring. (For the details of the holes for wiring, refer to
.)
• Place the flathead screwdriver vertical to the open/close button. In case the blade tip slips, it may cause an inverter damage
or injury.
• Wire removal
Cable gauge
(mm
2
)
Blade terminal
product number
Insulation cap
product number
Crimping tool
product number
0.3 to 0.75
BT 0.75-11
VC 0.75
NH 69
(3) Insert the wires into a socket.
When using a single wire or stranded wires without a blade terminal, push the
open/close button all the way down with a flathead screwdriver, and insert the
wire.
Pull the wire while pushing the open/close button all
the way down firmly with a flathead screwdriver.
NOTE
• Pulling out the wire forcefully without pushing the open/close
button all the way down may damage the terminal block.
• Use a small flathead screwdriver (tip thickness: 0.4 mm/tip
width: 2.5 mm).
If a flathead screwdriver with a narrow tip is used, terminal block
may be damaged.
Commercially available products (as of February 2016)
• Place the flathead screwdriver vertical to the open/close button.
In case the blade tip slips, it may cause an inverter damage or
injury.
Flathead screwdriver
Open/close button
Flathead screwdrive
Open/close button
Name
Model
Manufacturer
Driver
SZF
0- 0,4
2,5
Phoenix Contact Co., Ltd.