3-3
MAIN BOARD
1. Disconnect the connectors “S601”, “S602”, ”S101” and “GND”.
2. Remove the screw (P-#2CRBITS*4*8*15BF) and two screws (PL-CPIMS*4*10*15BF).
3. Disconnect the connectors “GND” and “S301”.
4. Remove the screw (P-#2CRBITS*4*8*15BF) .
5. Remove the Anode cap from CRT.
NOTE: Carefully discharge the CRT anode by shorting it to ground before removing anode cap.
Screw Screw
(P-#2CRBITS*4*8*15BF) (PL-CPIMS*4*10*15BF)
S602 S601 S101 GND
GND S301
Screw (P-#2CRBITS*4*8*15BF)