3-1
DISASSEMBLY
•
Before you disassemble the set, turn off power and pull out the power plug.
•
Use the appropriate screwdriver that fits the screw. If you use screwdriver that does not fit, you may break
the screws.
•
Assembly is the opposite process of Disassembly.
•
Carefully discharge the CRT anode by shorting it to ground before removing anode cap.
Revolving Stand ASSY
1. Turn the monitor CRT face down on a clean static free surface to prevent scratching CRT face.
2. Remove the screw (PL-CPTS*3*10*15BF) and remove by pulling up the Hooks and lifting the Revolving
stand Assy up to the side.
Cabinet Back
1. Remove the two screws (PL-CPTS*4*16*15BF) and unlock the two hooks.
Revolving Stand Assy
HOOK
Screw (PL-CPTS*3*10*15BF)
Screws (PL-CPTS*4*16*15BF)
Hook