Mitsubishi Heavy Industries RCN-E-E User Manual Download Page 5

CHECK MODE

ON/

OFF

CHECK

FILTER

CHECK

TIMER

RUN/

CHECK

4

 -

FILTER CHECK LAMP (RED)

When this lamp is blinked. clean the fi lter. (Refer to Page 9.)

REMOTE CONTROLLER SIGNAL RECEIVING SECTION

Receives a signal from the remote controller.

BACK UP BUTTON 

z

 When the batteries  are exhausted or if the remote controller is missing or defective, this button can be used to start or stop 

the air conditioner in  the makeshift mode. 

CHECK MODE

ON/

OFF

CHECK

FILTER

CHECK

TIMER

RUN/

CHECK

Back-up button

INDICATION BOARD 

CHECK MODE INDICATOR

When an irregularity occurs, the indicator indicates the status of malfunction by symbol. 
(Refer to Page 9.)

BACK UP BUTTON

When the remote controller is missing or defective, this button 
can start and stop the air conditioner. (Refer to bellow.)

RUN/CHECK LAMP

The lamp blinks are indicated in 3 patterns as follows.

z

 

Lit up in green 

: During operation

z

 

Blinked in green 

: "PREPARATION OF HEATING" 

   

  (during heating mode) (Refer to Page 10.)

z

 

Blinked in red 

: An irregularity occurs in the air 

   

  conditioner. (Refer to Page 9.)

„

  Press the back-up button 

The air conditioner starts. Set items are as follows. 

Operation mode

With auto mode: auto cooling

Without auto mode: cooling

Set temperature 

23°C

Fan speed

HI

Air fl ow direction

Horizontal

Timer

Invalid

„

  By pressing the switch once again,  the air conditioner stops

TIMER LAMP (GREEN)

This lamp is lit during the timer operation.

These lamps blink when 
the signal is received from 
the remote controller.
Each lamp blinks two times 
in the order from TIMER to 
RUN / CHECK (green) for 
receiving sign.

CHECK SWITCH

This switch is used for maintenance service.

PJZ012A055̲body̲1221.indd   4

PJZ012A055̲body̲1221.indd   4

2007/12/25   17:59:08

2007/12/25   17:59:08

Summary of Contents for RCN-E-E

Page 1: ...reiche mit einer Netzstromversorgung von 50 Hz Questo condizionatore d aria e conforme alla Direttiva EMC 89 336 EEC 92 31 EEC 93 68 EEC LV Direttiva 2006 95 EC Il marchio CE è applicabile alla fascia di alimentazione 50 Hz Deze airconditioner voldoet aan EMC Directive 89 336 EEC 92 31 EEC 93 68 EEC LV Directive 2006 95 EC CE markering is van toepassing op het gebied met een net stroom van 50 Hz E...

Page 2: ...t will help you when you have questions or problems Apart from the remote controller operation be sure to read the instruction manual enclosed with the indoor unit TABLE OF CONTENTS SAFETY PRECAUTIONS 2 INDICATION BOARD 4 BACK UP BUTTON 4 NAMES AND FUNCTIONS OF REMOTE CONTROLLER BUTTON 5 HOW TO OPERATE 6 CURRENT TIME SETTING PROCEDURE 6 ON TIMER OPERATION 7 OFF TIMER OPERATION 7 PROGRAM TIMER OPER...

Page 3: ...ditioner Dripping from the unit may lead to failure or contamination SAFETY PRECAUTIONS Please read these SAFETY PRECAUTIONS before starting to use this product and use the product appropriately according to the instructions The precautions provided here are classified into DANGER and CAUTION The DANGER sections describe potentially hazardous situations that may lead to serious outcomes such as de...

Page 4: ...e water heater etc near the indoor unit or remote control If a Vapor generating appliance is used near them it may lead to water drop causing electric leakage or short circuit Do not use the unit where powder or fiber is floating Fine powder or fiber passing through the air filter may stagnate inside the unit and lead to electric leak or short circuit Do not place objects under the unit which must...

Page 5: ... button can start and stop the air conditioner Refer to bellow RUN CHECK LAMP The lamp blinks are indicated in 3 patterns as follows z Lit up in green During operation z Blinked in green PREPARATION OF HEATING during heating mode Refer to Page 10 z Blinked in red An irregularity occurs in the air conditioner Refer to Page 9 Press the back up button The air conditioner starts Set items are as follo...

Page 6: ...eries when the remote controller is not used for a long time The recommendable effective period of a battery is about 6 to 12 months It depends on the usage The recommendable effective period is printed on the battery T h i s m ay b e s h o r t e r d u e t o manufacturing time of the unit However the battery may be still working in order after expiry date When the batteries are inserted each opera...

Page 7: ... on the remote controller 2 Press MODE button Current operation mode is indicated with the marks besides the operation mode icons The mode will change in the following order by pressing the button AUTO COOL HEAT FAN DRY 3 Press TEMP button Set the room temperature by pressing or bbutton 4 Press FAN SPEED button HI MED LO FAN SPEED can be changed in order 5 Press AIR FLOW button Effective AIR FLOW ...

Page 8: ...hen the air conditioner stops The air conditioner starts to operate OFF TIMER can be set only in case the air conditioner is in operation 2 Press OFF TIMER button OFF TIMER display blinks 3 Press or button to adjust to PM 9 00 Displayed time will be changed by 10 minutes by pressing the buttons 4 Press OFF timer button OFF TIMER display changes from blinking to steady lighting and the setting is c...

Page 9: ...tinuous movement of display Recommended air frow direction position when fixed A B C D COOL DRY AUTO HEAT FOR COMFORTABLE USE Clean the filter frequently If the filter is clogged The cooling heating capacity will get reduced Moreover it leads to waste of electricity and larger operation noise It may cause failure Dew may form and drop during cooling Do not block the inlet and outlet grilles of the...

Page 10: ...ess the ON OFF button to stay the air conditioner on the stop mode NOTICE The outside unit No is not displayed Address No Error code CHECK MODE WHEN THE FILTER CHECK LAMP RED IS LIT Clean the filter When cumulative running time reaches 120 hours long flashing light light for 2 seconds wink out for 1 second is shed from the filter check lamp red After cleaning of filter press the FILTER button on t...

Page 11: ...ing capacity The heating efficiency of heat pump type air conditioner decreases as the outside temperature becomes lower If the capacity of air conditioner for heating is not sufficient please use other heating device Time required until the room temperature increases A heat pump type air conditioner circulates warm air to warm the entire room so it takes a while to rise up the room temperature It...

Page 12: ...SUBISHI HEAVY INDUSTRIES EUROPE LTD AIR CONDITIONER DIVISION 3rd Floor Thavies Inn House 3 4 Holborn Circus London EC1N 2HA ENGLAND Phone 44 0 20 7842 8171 Fax 44 0 20 7842 8104 MITSUBISHI HEAVY INDUSTRIES AUSTRALIA PTY LTD 81 Railway Street Rockdale NSW 2216 Australia Phone 61 0 2 9597 7977 Fax 61 0 2 9597 7304 ...

Reviews: