20
(6) STOP (operation OFF) and ON TIMER standby
In the following cases, the horizontal vane returns to the closed position.
(a) When STOP/OPERATE (OFF/ON) button is pressed (POWER OFF).
(b) When the operation is stopped by the emergency operation.
(c) When ON TIMER is ON standby.
(7) Dew prevention
During COOL or DRY operation with the vane angle at Angle 3 or 4 when the compressor cumulative operation time
exceeds 1 hour, the vane angle automatically changes to Angle 1 for dew prevention.
(8) SWING (
) mode
By selecting SWING mode with VANE CONTROL button, the horizontal vanes swing vertically.
The remote controller displays "
". SWING mode is cancelled when VANE CONTROL button is pressed once again.
(9) Cold air prevention in HEAT operation
The horizontal vane position is set to Upward.
(10) ECONO COOL ( ) operation (ECONOmical operation)
When ECONO COOL button is pressed in COOL mode, set temperature is automatically set 2°C higher by the
microprocessor. However, the temperature on the LCD screen on the remote controller is not changed. Also the
horizontal vane swings in various cycle.
SWING operation makes you feel cooler than set temperature. So, even though the set temperature is higher, the
air conditioner can keep comfort. As a result, energy can be saved.
To cancel this operation, select a different mode or press one of the following buttons in ECONO COOL operation:
ECONO COOL, VANE CONTROL button.
In COOL, DRY and FAN operation
2 FLOW: Vane angle is fixed to position 2.
In HEAT operation
2 FLOW: Vane angle is fixed to position 2.
(5) VANE AUTO (
) mode
In VANE AUTO mode, the microprocessor automatically determines the vane angle to make the optimum room tem-
perature distribution.
1 FLOW: Vane angle is fixed to position 1.
1 FLOW: Vane angle is fixed to position 3.
OBH843