WIRELESS REMOTE CONTROLLER
MFZ-KT25VG MFZ-KT35VG MFZ-KT50VG MFZ-KT60VG
MICROPROCESSOR CONTROL
10
NOTE
: Last setting will be stored after the unit is turned OFF with the remote controller. Indoor unit receives the signal of the
remote controller with beeps.
Signal transmitting section
Operation display section
TEMPERATURE buttons
STOP/OPERATE
(OFF/ON) button
Indication of
remote controller
model is on back
Distance of signal :
About 6 m
Beep(s) is (are) heard from
the indoor unit when the
signal is received.
FAN SPEED CONTROL button
OPERATION SELECT button
ECONO COOL button
CLOCK button
Lid
Slide the lid down
to open the remote
controller. Slide it down
further to get to the
weekly timer buttons.
WEEKLY TIMER
set buttons
TIME, TIMER set buttons
FORWARD button
BACKWARD button
RESET button
i-save button
VANE CONTROL button
AMPM
AMPM
INDOOR UNIT DISPLAY SECTION
Operation Indicator lamp
The operation indicator at the right side of the indoor unit indicates the operation state.
•The following indication applies regardless of shape of the indication.
Indication
Operation state
Room temperature
The unit is operating to
reach the set temperature
About 2°C or more
away from set tempera-
ture
The room temperature is
approaching the set tem-
perature
About 1 to 2°C from
set temperature
Standby mode (only during
multi system operation)
—
Lit
Blinking
Not lit
10-1. COOL ( ) OPERATION
(1) Press STOP/OPERATE (OFF/ON) button.
OPERATION INDICATOR lamp of the indoor unit turns on with a beep tone.
(2) Select COOL mode with OPERATION SELECT button.
(3) Press TEMPERATURE buttons TEMP
or
button to select the set temperature. The setting range is 16 - 31°C.
1. Coil frost prevention
The compressor operational frequency is controlled by the temperature of the indoor heat exchanger to prevent the coil
from frosting.
When the temperature of indoor heat exchanger becomes too low, the coil frost prevention mode works.
The indoor fan operates at the set speed and the compressor stops. This mode continues until the temperature of indoor
heat exchanger rises.
2. Low outside temperature operation
When the outside temperature is lower, low outside temperature operation starts, and the outdoor fan slows or stops.
3. Indoor fan speed control
When the thermostat turns OFF, the indoor fan operates at the setting fan speed.