7
SPECIFICATION
4
Function
Power supply
Outdoor Service Ref.
Capacity Rated frequency(Min.~Max.)
Dehumidification
Air flow(High/Low
w
)
Starting current
✽
1
Compressor motor current
✽
1
Fan motor current
✽
1
Model
Output
Winding
resistance(at 20
:
)
Model
Winding
resistance(at 20
:
)
Dimensions W
O
H
O
D
Weight
Sound level
✽
1
Fan speed(High
w
/Low
w
, High
w
/Med
w
/Low
w
)
Fan speed regulator
Refrigerant filling
capacity(R410A)
Refrigerating oil (Model)
Thermistor RT61 (at 0
:
)
Thermistor RT62 (at 100
:
)
Thermistor RT64 (at 50
:
)
Thermistor RT65 (at 25
:
)
Thermistor RT61 (at 25
:
)
Thermistor RT62 (at 100
:
)
Thermistor RT64 (at 50
:
)
Thermistor RT65 (at 25
:
)
Thermistor RT68 (at 25
:
)
kW
r
/h
K
/h
A
A
A
W
"
"
mm
kg
dB
rpm
kg
cc
k
"
k
"
k
"
k
"
k
"
k
"
k
"
k
"
k
"
Single phase
230V,50Hz
3.65
KNB073FDVH
550
U-V 1.53 U-W 1.53
V-W 1.53
RC0J50-AL
WHT-BLK 37.5
BLK-RED 37.5
RED-WHT 37.5
800
o
550
o
285
33
46
0.90
320 (NEO22)
32.6
13.4
17
10
—
—
—
—
—
Cooling
2.5(0.9-3.2)
0.5
2,058
2.74
0.31
3.62
810
w
/650
w
2
880
w
/810
w
/650
w
3
840
w
/760
w
2
880
w
/800
w
/630
w
3
Heating
3.0(0.9-4.5)
—
1,938
3.37
0.28
3.61
SUZ-KA25VA(H).TH
Indoor Service Ref.
SLZ-KA25VA(L).TH
Indoor Service Ref.
SLZ-KA35VA(L).TH
Compressor
Fan
motor
Special
remarks
Coefficient of performance (C.O.P)
✽
1
Capacity
Electrical
data
SUZ-KA35VA(H).TH
Single phase
230V,50Hz
2,004
4.75
KNB092FCAH
650
U-V 0.49 U-W 0.49
V-W 0.49
RC0J50-AL
WHT-BLK 37.5
BLK-RED 37.5
RED-WHT 37.5
800
o
550
o
285
37
1.05
320 (NEO22)
32.6
13.4
17
10
—
—
—
—
—
Cooling
3.5(1.0-3.9)
1.2
4.22
0.33
3.30
47
Heating
4.0(0.9-5.0)
—
4.42
0.33
3.64
48
Indoor Service Ref.
SLZ-KA50VA(L).TH
SUZ-KA50VA.TH
Single phase
230V,50Hz
6.75
0.30
SNB130FLDH
850
U-V 0.45 U-W 0.45
V-W 0.45
PM8H60-UB
WHT-BLK 15.2
BLK-RED 15.2
RED-WHT 15.2
840
o
850
o
330
53
2
1.60
450 (NEO22)
—
—
—
—
10.0
13.4
17.0
10.0
10.0
Cooling
4.6(1.1-5.2)
2.2
2,940/1,650
w
6.45
2.82
53/51
w
800/480
w
Heating
5.0(0.9-6.5)
—
2,940/2,210
w
6.05
3.23
55/53
w
800/620
w
NOTE : Test conditions are based on ISO 5151
Cooling : Indoor
D.B. 27
:
W.B. 19
:
Outdoor D.B. 35
:
W.B. 24
:
Heating : Indoor
D.B. 20
:
W.B. 15
:
Outdoor D.B. 7
:
W.B. 6
:
Refrigerant piping length (one way): 5m
✽
1 Measured under rated operating frequency.
w
Reference value
SLZ-KA•VA(L).TH / SUZ-KA•VA(H).TH
OC322A--1qxp 05.10.19 3:28 PM Page 7