24
2
Air flow : High speed
3
Operational frequency : 58Hz(SUZ-KA25VA(H).TH)
73Hz(SUZ-KA35VA(H).TH)
75Hz(SUZ-KA50VA.TH)
Outdoor unit current(A)
15
20
50
25
60
30
70 (%)
35(˚C)
3
3.5
4
4.5
5
73Hz
32
18
Ambient temperature(˚C) Ambient humidity(%)
SUZ-KA35VA(H).TH
15
20
50
25
60
30
70 (%)
35(˚C)
2
2.5
3
3.5
4
58Hz
32
18
Outdoor unit current(A)
Ambient temperature(˚C) Ambient humidity(%)
SUZ-KA25VA(H).TH
(MPa [Gauge])
(kgf/
F
[Gauge])
18
32
15
20
50
25
60
30
70 (%)
35(˚C)
0.2
0.4
0.6
0.8
1.0
1.2
58Hz
2
4
6
8
10
12
14
1.4
Ambient temperature(˚C) Ambient humidity(%)
Outdoor low pressure
SUZ-KA25VA(H).TH
(MPa [Gauge])
(kgf/
F
[Gauge])
18
32
15
20
50
25
60
30
70 (%)
35(˚C)
0.2
0.4
0.6
0.8
1.0
1.2
73Hz
1.4
Ambient temperature(˚C) Ambient humidity(%)
Outdoor low pressure
SUZ-KA35VA(H).TH
2
4
6
8
10
12
14
Outdoor unit current(A)
15
20
50
25
60
30
70 (%)
35(˚C)
5.0
6.0
7.0
8.0
9.0
75Hz
32
18
Ambient temperature(˚C) Ambient humidity(%)
SUZ-KA50VA.TH
(MPa [Gauge])
(kgf/
F
[Gauge])
18
32
15
20
50
25
60
30
70 (%)
35(˚C)
0.2
0.4
0.6
0.8
1.0
1.2
75Hz
1.4
Ambient temperature(˚C) Ambient humidity(%)
Outdoor low pressure
SUZ-KA50VA.TH
2
4
6
8
10
12
14
OUTDOOR LOW PRESSURE AND OUTDOOR UNIT CURRENT
COOL operation
1
Both indoor and outdoor unit are under the
same temperature/humidity condition.
Dry-bulb temperature
Relative humidity(%)
20
50
25
60
30
70
HEAT operation
Condition indoor: Dry bulb temperature 20.0°C
Wet bulb temperature 14.5°C
Condition outdoor: Dry bulb temperature 2,7,15,20.0°C
Wet bulb temperature 1,6,12,14.5°C
SUZ-KA25VA(H).TH
Outdoor unit current (A)
Ambient temperature(˚C)
3.0
2.5
2.0
1.5
1.0
0.5
0.0
2
5
10
15
20 25(
:
)
58Hz
SUZ-KA35VA(H).TH
Outdoor unit current (A)
Ambient temperature(˚C)
4.0
3.5
3.0
2.5
2.0
1.5
1.0
2
5
10
15
20 25(
:
)
58Hz
SUZ-KA50VA.TH
Outdoor unit current (A)
Ambient temperature(˚C)
7.0
6.0
5.0
4.0
3.0
2.0
1.0
2
5
10
15
20 25(
:
)
58Hz
OC322A--1qxp 05.10.19 3:28 PM Page 24