6.1. For Wired Remote-controller
You can use Function Selection of remote controller to select which of
three types of timer to use:
1
Weekly timer,
2
Simple timer, or
3
Auto
Off timer.
6.1.1. Weekly Timer
■
The weekly timer can be used to set up to eight operations for each day
of the week.
• Each operation may consist of any of the following: ON/OFF time to
-
gether with a temperature setting, or ON/OFF time only, or temperature
setting only.
• When the current time reaches a time set at this timer, the air condi
-
tioner carries out the action set by the timer.
■
Time setting resolution for this timer is 1 minute.
Note:
*1. Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same
time.
*2. The weekly timer will not operate when any of the following conditions is
in effect.
The timer feature is off; the system is in an malfunction state; a test run
is in progress; the remote controller is undergoing self-check or remote
controller check; the user is in the process of setting a function; the user
is in the process of setting the timer; the user is in the process of setting
the current day of the week or time; the system is under central control.
(Specifically, the system will not carry out operations (unit on, unit off, or
temperature setting) that are prohibited during these conditions.)
Operation No.
Day Setting
<How to Set the Weekly Timer>
1. Be sure that you are at a standard control screen, and that the weekly
timer indicator
1
is shown in the display.
2. Press the Timer Menu button
B
, so that the “Set Up” appears on the
screen (at
2
). (Note that each press of the button toggles the display
between “Set Up” and “Monitor”.)
3. Press the Timer On/Off (Set Day) button
9
to set the day. Each press
advances the display at
3
to the next setting, in the following sequence:
“Sun Mon Tues Wed Thurs Fri Sat”
→
“Sun”
→
...
→
“Fri”
→
“Sat”
→
“Sun Mon Tues Wed Thurs Fri Sat”...
4. Press the
or
Operation button (
7
or
8
) as necessary to select the
appropriate operation number (1 to 8)
4
.
* Your inputs at Steps 3 and 4 will select one of the cells from the matrix
illustrated below.
(The remote-controller display at left shows how the display would
appear when setting Operation 1 for Sunday to the values indicated
below.)
6. Timer
5. Operation
Low
High
5.6. Ventilation
► For LOSSNAY combination
5.6.1. For Wired Remote-controller
●
To run the ventilator together with the indoor unit:
■
Press the ON/OFF button
1
.
• The Vent indication appears on the screen (at
8
). The ventilator will
now automatically operate whenever the indoor unit is running.
●
To run the ventilator independently:
■
Press the Mode button
2
until
appears on the display. This will
cause the ventilator to start.
5.6.2. For Wireless Remote-controller
●
The Ventilation will automatically operate when the indoor unit turns
on.
●
No indication on the wireless remote controller.
●
To change the ventilator force:
■
Press the Ventilation button
8
as necessary.
• Each press toggles the setting, as shown below.
Note:
By setting the day to “Sun Mon Tues Wed Thurs Fri Sat”, you can set the same
operation to be carried out at the same time every day.
(Example: Operation 2 above, which is the same for all days of the week.)
<Setting the Weekly Timer>
Setup Matrix
Shows the selected operation (ON or OFF)
* Does not appear if operation is not set.
Shows the temperature setting
* Does not appear if temperature is not
set.
Shows the time
setting
5. Press the appropriate Set Time button
A
as necessary to set the
desired time (at
5
).
* As you hold the button down, the time first increments in minute in
-
tervals, then in ten-minute intervals, and then in one-hour intervals.
6. Press the ON/OFF button
1
to select the desired operation (ON or
OFF), at
6
.
* Each press changes the next setting, in the following sequence:
No display (no setting)
→
“ON”
→
“OFF”
▲
▲
Op No.
Sunday
Monday
…
Saturday
No. 1
• 8:30
• ON
• 23 °C
No. 2
• 10:00
• OFF
• 10:00
• OFF
• 10:00
• OFF
• 10:00
• OFF
…
No. 8
▲
<Operation 1 settings for Sunday>
Start the air conditioner at 8:30, with
the temperature set to 23 °C.
▲
<Operation 2 settings for every day>
Turn off the air conditioner at 10:00.
BG79U786H06_en.indd 7