4. Trouble criterion of main parts
SLH-1AR.TH
SLH-1.6AR.TH
SLH-2AR.TH
SLH-1AR
1
.TH
SLH-1.6AR
1
.TH
SLH-2AR
1
.TH
SL-1AR.TH
SL-1.6AR.TH
SL-2AR.TH
SL-1AR.TH-T
SL-1.6AR.TH-T
SL-2AR.TH-T
BLK
RED ORN
YLW
BLU
BRN
WHT
P
Room temperature
thermistor
(RT11)
Measure the resistance with a tester.
(Part temperature 10
°
C ~ 30
°
C)
Measure the resistance between the terminals with a tester.
(Coil wiring temperature 10
°
C ~ 30
°
C)
Indoor coil thermistor
(RT12)
Indoor fan motor
(MF)
Check method and criterion
Part name
Normal
1AR
Normal
WHT-BLK
BLK-BLU
BLU-YLW
YLW-BRN
BRN-RED
296~320
55~59
34~36
37~41
260~282
1.6AR
309~399
107~115
47~51
44~48
299~323
2AR
305~329
85~92
50~54
43~47
289~313
4.3k
Ω
~9.6k
Ω
Abnormal
Abnormal
Opened or
short-circuited
Opened or short-circuited
Measure the resistance between the terminals using a tester.
(Surrounding temperature 20
:
~30
:
)
Measure the resistance between the terminals using a tester.
(Surrounding temperature 20
:
~30
:
)
Measure the resistance between the terminals using a tester.
(Surrounding temperature 10
:
~30
:
)
Vane motor (MV)
Drain pump (DP)
Drain sensor (DS)
(Refer to the thermistor)
1
2
Yellow
Yellow
1
2
3
Abnormal
Open or short
Normal
0.6k
"
~6.0k
"
Normal
Connector
Abnormal
300
"
Open or short
Normal
Abnormal
290
"
Open or short
Orange
Red
White
Red — Yellow
Red — Blue
Red — Orange
Red — White
Blue
Yellow
3
5
1
2
4
M