9
4
DATA
4-1. REFILLING REFRIGERANT CHARGE (R410A: kg)
4-2. COMPRESSOR TECHNICAL DATA
Additional charge is required for pipes longer than
30 m (SHW80/SHW112) and 10 m (SW75/SW100).
Service Ref.
Piping length (one way)
Initial
charged
10 m
20 m
30 m
40 m
50 m
60 m
75 m
PUHZ-SHW80VAA(-BS).UK
PUHZ-SHW112VAA(-BS).UK
PUHZ-SHW80YAA(-BS).UK
PUHZ-SHW112YAA(-BS).UK
4.6
4.6
4.6
5.2
5.6
5.8
6.0
4.6
PUHZ-SW75VAA(-BS).UK
PUHZ-SW75YAA(-BS).UK
3.0
3.6
4.2
4.8
—
—
—
3.0
PUHZ-SW100VAA(-BS).UK
PUHZ-SW100YAA(-BS).UK
4.2
4.4
4.6
5.2
5.6
5.8
6.0
4.2
Service Ref.
PUHZ-SHW80VAA(-BS).UK
PUHZ-SHW112VAA(-BS).UK
PUHZ-SHW80YAA(-BS).UK
PUHZ-SHW112YAA(-BS).UK
PUHZ-SW75VAA(-BS).UK
PUHZ-SW75YAA(-BS).UK
Compressor model
DNK28FBAMT
DNK28FBBMT
SNB220FEGMC-L1
SNB220FEAMC-L1
Winding
Resistance (Ω)
U-V
0.74
0.94
0.95
1.65
U-W
0.74
0.94
0.95
1.65
W-V
0.74
0.94
0.95
1.65
(at 20
:
)
Service Ref.
PUHZ-SW100VAA(-BS).UK
PUHZ-SW100YAA(-BS).UK
Compressor model
DNB28FBAMT
DNB28FBBMT
Winding
Resistance (Ω)
U-V
0.74
0.94
U-W
0.74
0.94
W-V
0.74
0.94
OCH651