17
NOTE:
1. Rating conditions (ISO T1)
Cooling Indoor : D.B. 27
:
(80˚F) W.B. 19
:
(66˚F)
Outdoor : D.B. 35
:
(95˚F) W.B. 24
:
(75˚F)
Heating Indoor : D.B. 20
:
(68˚F)
Outdoor : D.B. 7
:
(45˚F)
W.B. 6
:
(43˚F)
Refrigerant piping length (one way) : 5m (16ft.)
2. Guaranteed operating range
Indoor
Outdoor
Cooling
Upper limit D.B. 35˚C, W.B. 22.5˚C D.B. 46
:
Lower limit D.B. 19˚C, W.B. 15˚C
D.B. -5
:
w
Heating
Upper limit D.B. 28˚C
D.B. 21
:
, W.B. 15
:
Lower limit D.B. 17˚C
D.B. -20
:
, W.B. -20
:
4. Above data based on indicated voltage
w
If optional Air protect guide installed. D.B.-15
:
Indoor unit
Single phase 230V 50Hz
Single phase 230V 50Hz
Outdoor unit
3. Guaranteed voltage
198~264V, 50Hz
Model name
Indoor unit
PCA-RP100GA
PCA-RP125GA
PCA-RP140GA
Outdoor unit
PUHZ-RP100VHA2
PUHZ-RP125VHA2
PUHZ-RP140VHA2
Cooling
Capacity
Btu/h
34,100
42,700
47,800
kW
10.0(4.9-11.4)
12.5(5.5-14.0)
14.0(5.5-15.3)
Total input
kW
2.92
3.88
4.65
EER
3.42
3.22
3.01
Energy label class
A
A
B
SHF
0.75
0.77
0.75
Heating
Capacity
Btu/h
38,200
47,800
54,600
kW
11.2(4.5-14.0)
14.0(5.0-16.0)
16.0(5.0-18.0)
Total input
kW
3.26
4.11
4.60
COP
3.44
3.41
3.48
Energy label class
B
B
B
Booster heater
kW
-
-
-
Power supply
Phase
[
1
Cycle
Hz
50
Voltage
V
230
Breaker size
A
32
40
Indoor unit
Air flow
CMM
20-21-23-25
27-30-32-34
(Low-Medium2-Medium1-High)
CFM
705-840-810-885
955-1060-1130-1200
External pressure
Pa
0
0
Sound level
dB(A)
40-41-43-45
41-43-45-46
42-44-46-48
(Low-Medium2-Medium1-High)
External finish
White Munsell 0.70Y 8.59/0.97
Dimension
W : mm
1310
1620
D : mm
680
H : mm
270
W : inch
51-9/16
63-3/4
D : inch
26-3/4
H : inch
10-5/8
Weight
kg
37
43
45
lbs
82
95
99
Unit drain pipe I.D.
mm
26
inch
1
Outdoor unit
Air flow
CMM
100
CFM
3,530
Sound level at cooling
dB(A)
49
50
Sound level at heating
dB(A)
51
52
External finish
Ivory Munsell 3Y 7.8/1.1
Dimension
W : mm
950
D : mm
330+30
H : mm
1350
W : inch
37-3/8
D : inch
13 + 1-3/16
H : inch
53-1/8
Weight
kg
121
116
lbs
267
256
Refrigerant pipe size
Gas side O.D.
mm
15.88
inch
5/8
Liquid side O.D.
mm
9.52
inch
3/8
Refrigerant pipe length
Height difference
m
Max. 30
Length
m
Max. 75
OCS05A-1.qxp 06.5.15 0:50 PM Page 17
Summary of Contents for PUHZ-RP140VHA2
Page 40: ...40 WIRED REMOTE CONTROLLER Unit mm 130 120 19 ...
Page 41: ...41 WIRELESS REMOTE CONTROLLER Unit mm 159 3 55 58 19 ...
Page 65: ...65 9 2 PLA RP AA 2 9 2 1 FRESH AIR INTAKE AMOUNT ...
Page 66: ...66 ...
Page 67: ...67 9 2 2 BRANCH DUCT Installation at site ...
Page 76: ...76 PEAD RP60GA PEAD RP71GA ...
Page 77: ...77 PEAD RP100GA ...
Page 81: ...81 ...