18
PUH-P5YGA, PU-P5YGA
PUH-P6YGA, PU-P6YGA
398
w
1 458
w
1 434
1033
Earth Point
T
erminal Connections
Left...Power supply Wiring
Right..Indoor/Outdoor Wiring
Handle
Side
Air
Intake
Rear
Air
Intake
Handle
Side
Air
Intake
2-12x40 oval holes
(Foundation Bolt M10)
2-U Shaped notched holes
(Foundation Bolt M10)
Rear
Air Intake
Air Discharge
Handle
Service Panel
Drain Hole
(5-
[
33Holes)
Bottom Piping Hole
(Knock-Out)
Rear Piping Cover
Front Piping Cover
[
92
92
65
63
68
55
22
33
40
Rear
T
runking Hole
(Knock-Out)
< Rear Side >
Rear Piping Hole
(Knock-Out)
Power Supply Wiring Hole
(2-
[
27Knock-Out)
40
55
[
92
33
100
50
50
100
27
33
92
65
55
22
63
68
40
< Right Side >
Right Piping Hole
(Knock-Out)
< Front Side >
Power Supply Wiring Hole
(2-
[
27Knock-Out)
Power Supply Wiring Hole
(2-
[
27Knock-Out)
Front
T
runking Hole
(Knock-Out)
Front Piping Hole
(Knock-Out)
Piping Knock-Out Hole Details
70
18
18
90
148
148
148
172
30
109
215
85
598
1
2
1050
352
50
225
600
53
370
(14)
29
330
20
Installation Feet
44
53
58
3
230
295
295
230
5
5
1246
FOUNDA
TION
30mm
<Foundation bolt height>
Less than
Over500
Over100
Service Space
Over500
Over10
The diagram below shows a
basic example.
Explanation of particular details are
given in the installation manuals etc.
SER
VICE SP
ACE
1
FREE SP
ACE (Around the Unit)
2
3
FOUNDA
TION BOL
TS
Please secure the unit firmly
with 4 foundation (M10) bolts.
(Bolts and washers must be
purchased locally).
Dimensions of space needed
for service access are
shown in the below diagram.
4
PIPING-WIRING DIRECTIONS
Piping and wiring connections
can be made from 4 directions:
Front, Right, Rear and Below
.
Over 10mm
F
R
E
E
Over 500mm
Over 100mm
Over 10mm
Explanation of Notes
. . .
Refrigerant GAS pipe connection(FLARE)
[
19.05 (3/4F)
. . .
Refrigerant LIQUID pipe connection(FLARE)
[
9.52 (3/8F)
. . .
Height of ST
OP
V
AL
VE connection location.
. . .
3-
[
3.6 holes (for securing the top of the unit)
These holes are provided for cases where the unit must
be secured by the base
AND by the top surface together
.
Use Self
T
apping screws 5 x L15 or less.
(Obtained Locally)
3
2
1
w
1
Unit : mm
OC180A--1.qxp 3/3/00 8:44 AM Page 18
Summary of Contents for PU-P1.6VGA
Page 2: ...OC180A 1 qxp 3 3 00 8 43 AM Page 2 ...
Page 19: ...19 7 WIRING DIAGRAM PUH P1 6 2 2 5 3VGA PUH P2 5VGA1 OC180A 1 qxp 3 3 00 8 44 AM Page 19 ...
Page 20: ...20 PUH P1 6 2 2 5 3 4 5 6YGA PUH P2 5YGA1 OC180A 1 qxp 3 3 00 8 44 AM Page 20 ...
Page 21: ...21 PU P1 6 2 2 5 3VGA PU P2 5VGA1 OC180A 1 qxp 3 3 00 8 45 AM Page 21 ...
Page 22: ...22 PU P3 4 5 6YGA OC180A 1 qxp 3 3 00 8 45 AM Page 22 ...