background image

14

PUHY-P500YGM-A (Connected with PFD series)

*1

*1

black

white

red

LEV1

NOTE:The broken lines indicate field wiring.

ON/OFF

Compressor

SHORT

CN3D

1-2P

1-3P

CN3D

OPEN

ON

OFF

OPEN

SHORT

ON

OFF

NIGHT

MODE

*1: Function according to switch operation.

      (SW4-7,CN3D 1-2P,and CN3D 1-3P)

SW4-7:OFF (Compressor ON/OFF 

                      and NIGHT MODE)

Gas pipe temp.detect (Hex outlet)

TH2

Magnetic contactor(Fan motor)

52F

Overload relay(No.2Compressor)

51C2

Magnetic contactor(No.2Compressor)

52C2

DC Current Sensor

DCCT

<Symbol explanation>

Symbol

Name

ACCT

DCL

52C1

MF3

CH11,12

21S4a,b,c

SV1,3

SV5b,c

LEV1

TH11,12

TH5

TH6

TH7

TH8

THHS1

63H1,2

63HS

63LS

L1,L2

Z20

AC Current Sensor

DC reactor (Power factor improvement)

Magnetic contactor (Inverter main circuit)

Solenoid valve (Discharge-suction bypass)

Solenoid valve (Heat exchanger capacity control)

Electronic expansion valve (SC coil)

Fan motor (Radiator panel)

Crank case heater(Compressor)

4-way valve

Thermistor

Discharge pipe temp. detect

Pipe temp.detect(Hex outlet)

OA temp.detect

liquid outlet temp.detect at Sub-cool coil

bypass outlet temp.detect at Sub-cool coil

Radiator panel temp. detect (Compressor)

High pressure switch

High pressure sensor

Low pressure sensor

Choke coil(Transmission)

Function  device

Earth terminal

THHS5

Radiator panel temp. detect(Fan)

Motor

(Compressor)

Fan motor

(Heat exchanger)

Fan motor

(Heat exchanger)

black

white

red

Motor

(Compressor)

black

white

red

white

blue

white

red

power selection

connector

detection

circuit

detection

circuit

detection

circuit

Inverter controller box

red

white

black

CNH

CNL black

1

63HS

63LS

33

2

black 
white 
red

2

2

3

1

123

1

black

red

DS

(Diode stack)

black

white

red

Function setting

LED1 operation

LED2 error

Power circuit board

Gate amp board 

Filter board

T01

(Transfomer)

LED1 operation

LED2 error

FAN control board

Compressor ON/OFF

Trouble

Compressor ON/OFF

NIGHT MODE

SNOW

Refer to the service handbook

about the switch operations.

Address setting

Function setting

Maintenance

setting

Control circuit board

TB3

(Terminal Block)

TB7

(Terminal Block)

TB1

(Terminal Block)

ACNF

(Noise Filter)

M2

M1

M2

M1

shield

shield

CENTRAL CONTROL

 TRANSMISSION LINE

INDOOR/OUTDOOR

 TRANSMISSION LINE

Power source

3N

~

380/400/415V

50/60Hz

L3

N

L1

L2

blue

black

white

red

blue

N

1

9

2

1

9

1

5 6

10

9

14

13

10

14

13

9

6

5

1 2

black

red

red

black

10

1

SW5

OFF

OFF

ON

OFF

ON

OFF

OFF

ON

ON

ON

LD1

SW4

SW3

S

W2

SW1

10

1

10

1

10

1

10

1

DCCT

L3

L2

1

2

S

F12

AC660V

50A F

F11

AC660V

50A F

red

white

black

U

17

W

V

MC2

1

1

3

2

1

F01

250VAC

2A T

CNAC2

CNCT

1

2

N

R2

C1

C2

R1

R4

R3

CNDC1

black

CN15V1

CNDR1

CNDC2

ACCT-W

ACCT-U

ACCT

CNDR2

F02

700VDC

2A T

CN15V2

THHS1

CNTH

green

CNFG

blue

CNDC2

CNCT2

blue

CNVCC1

CNFAN

red

CNRS1

CNL1

CNL2

CNFG

blue

CNIN

blue

CN41

CNOUT

green

CNINV

CN21

blue

CNS1

blue

CN20

F02

250VAC

6.3A T

CN40

F01

250VAC

6.3A T

CNVDC

CNS2

blue

CNRS3B

CNVCC1

CNRS3A

CN51

CN3S

 red

8

2 1 0

SWU3

SWU1

SWU2

CN52C

yellow

CN32

CN33

CN34

 red

CN36

CN35

green

CNTYP5

CNTYP4

R23

R22

CN01

TH11

CNTYP1

red

black

CNTR

CNRS2

4

Z20

L3

3

2

8

1

1

8

51C2

6

4

2

red

34
12

U

4

3

MF2

3

X09

L1

52C1

DCL

N

IPM

P

C4

MC1

V

X52

U

E

C5

ZNR4

X01

1

8

W

2

3

2

X07

1

CNRT1

1

CN13

TH12

52

C1

5

1

3

2

1

7

32

14

56

12V

4

3

1

21

3

21

21

2

7

1

5

4

3
12

3

2

1

1

L3

L2

4

4 5

3

1 2

CN3D

2

3

1

3

1

X03

1

3

2

1 2 3

X02

X08

W

V

L1

U

L2

L3

63H1

52F

51C2

2 3 4

1

3

2

L1

12

12

1

8

5 6

1

X05

X06

9

4

6

3
14

2

1

1

4

4

SW1

OFF

2

4 3

1

 ON

6

3

41

2

2

W

SW2

OFF

1

 ON

4

V

1

2

5
34
12

2 1

3

4

1

1

4

L2

3

CN02

2

1

7

8

CNOUT2

5

6

3

2

CNRT2

CNCH

CN52F

CN51C2

4

5

3 2 1

5432

2

11

7

6

X2

X3

5

4

X1

1

1

1

3

2

2

7

CN52C2

  blue

3

5

4

3

2

52

C2

1

3

1 2

52C2

TH5

TH6

TH7

21S

 4a

SV1

SV3

PE

A1             A2

gray                      yellow

CH12

A2             A1

13   14

brown                   purple

red

orange

63H2

 red

95  96

white                     black

52C2

21S

 4c

V

W

6

CNOUT1

yellow

2

1

3

2

1

3

3

2

1

CN05

SV

5c

CN04

52F

blue

A2

L1

L2

3

21

Relay board

orange yellow

red

brown

THHS5

4

A1

7

4

1

CNTH

green

4

2

1

3

2

1

X01

+

+

~

~

~

+

black

MF3

CNLVB

red

SV

5b

CNAC3

2

1

TH8

red

white

21S

 4b

CH11

3

2

1

MF1

W

V

U

3

2

1

1

3

2

LD2

1

U

CN38

5

3

black

2

2

yellow

L1

Summary of Contents for PU(H)Y-P250YGM-A

Page 1: ...g System 7 2 Control Wiring 7 3 Types of switch settings and setting methods 7 4 Sample System Connection 7 5 External input output specifications 8 Air Conditioning the Computer Room 8 1 Main Features of the Floor Duct Air Conditioners 8 2 Features of air conditioner for computer room 8 3 Step by Step Plan for the Implementation of the Air Conditioning 8 4 Conditions for the Installation of Compu...

Page 2: ......

Page 3: ... connects the indoor and outdoor units This system consists of single refrigerant circuit 3 Indicates TB7 Type transmission line that allows the unit to communicate with the controller When using a PFD P250VM E as an indoor unit connect an outdoor unit PUHY P250YGM A to each indoor unit and operate with a built in remote control for the indoor unit 1 Bold line indicates refrigerant piping gas liqu...

Page 4: ...t 2 PUHY P250YGM A outdoor units to each indoor unit and operate with a built in remote control for the indoor unit At factory shipment this model of indoor unit is designed and set to accommodate a single refriger ant circuit Connection of two refrigerant circuits to the indoor unit requires setting change and pipe work 1 Bold line indicates refrigerant piping gas liquid This system consists of t...

Page 5: ...ation Manual Indoor 27 CDB 19 CWB Indoor 20 CDB Pipe length 7 5m Outdoor Outdoor Height difference 0m 35 CDB 7 CDB 6 CWB Cooling Heating 3N 380 400 415V 50Hz 400 415V 60Hz PFD P500VM E 5 0 Power source kW Power input System capacity A m3 min Pa kg dB A m mm Current Heat exchanger Fan Refrigerant External finish Type x Quantity Airflow rate External static pressure kW Motor Output Air filter Refrig...

Page 6: ...5 12 24 0 7 0 8 0 9 1 0 1 1 1 2 1 3 19 24 15 12 15 10 5 0 5 10 15 20 25 30 35 40 45 Capacity correction coefficient Input Correction Coefficient Outdoor unit inlet temperature CDB Outdoor unit inlet temperature CDB 2 2 Cooling Input The correction curves indicate the values measured at the point where the compressor was operated at its maximum capacity indicates the standard value ...

Page 7: ...or 27 CDB 19 CWB Outdoor 35 CDB 0 4 0 5 0 6 0 7 0 8 0 9 1 30 40 50 60 70 80 RH SHF 130 120 110 100 90 80 70 Standard Capacity Ratio Standard Capacity Ratio 0 93 0 4 0 5 0 6 0 7 0 8 0 9 1 30 40 50 60 70 80 RH SHF 130 120 110 100 90 80 70 35 45 55 65 75 Indoor Temperature 27 CDB 35 45 55 65 75 Indoor Temperature 24 CDB ...

Page 8: ...piping m How to obtain piping equivalent length Piping equivalent length m Capacity correction coefficient 0 7 0 8 0 9 1 0 20 40 60 80 100 120 140 160 180 2 5 Operation limit Indoor temperature CWB 15 0 5 10 5 10 15 20 25 30 35 40 45 10 12 15 20 25 30 The height between the Outdoor PUHY P YGM A and Indoor could make the running temperature range narrow For details refer to P19 7 1 Refrigerant Pipi...

Page 9: ...oise Level 7 1m 1m Measured point Series Noise Level dB Type A PFD P250VM E 59 PFD P500VM E 63 1 Outdoor Unit 2 Indoor Unit Measured point 1m 1m Series Noise Level dB Type A PUHY P250YGM A 57 PUHY P500YGM A 60 61 50Hz 60Hz ...

Page 10: ... 4000Hz 8000Hz dB A 70 6 62 7 60 5 56 1 54 8 45 7 39 7 32 9 59 10 20 30 40 50 60 70 80 90 63Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz 10 20 30 40 50 60 70 80 90 63Hz 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz 8000Hz NC 70 NC 60 NC 50 NC 40 NC 30 NC 20 NC 70 NC 60 NC 50 NC 40 NC 30 NC 20 OCTAVE BAND PRESSURE LEVEL dB 0dB 20µPa OCTAVE BAND PRESSURE LEVEL dB 0dB 20µPa OCTAVE BAND CENTER FREQUENCIE...

Page 11: ...s ø22 2 Brazed Mounting hole Air outlet Air inlet Air inlet ø62 Knockout hole Hole for power supply Changeable to ø27 ø33 by using attached conduit mounting plate Accessory ø27 Knockout hole Bottom hole for control wiring Knockout hole Bottom piping hole Left side view ø27 Knockout hole Left side hole for control wiring Knockout hole Left piping hole Accessories Refrigerant Gas conn pipe 1 pc Alre...

Page 12: ...15 88 Flare Y Y Y Y X X Mounting hole Knockout hole Bottom piping hole ø27 Knockout hole Bottom hole for control wiring ø62 Knockout hole Hole for power supply Changeable to ø46 ø53 by using attached conduit mounting plate Accessory Accessories Refrigerant Gas conn pipe 1 pc Already installed on the unit Packing for conn pipe 1 pc Attached near the ball valve Conduit mounting plate ø53 ø46 1 pc Ea...

Page 13: ...ower supply Body Nomal Local 1380 Remote controller A Refrig piping gas ø22 2 braze Power supply White Operating Green Check Yellow Failure Red Accessory Filter Lamp view from A 320 220 1950 20 100 462 580 Panel ø32 knook out hole Air inlet Control box 50 140 Hole for the control wiring ø32 knook out hole Main drain piping connection Rp1 1 4 Accessory Lifting bolts 4pc Front panel opening and clos...

Page 14: ...ce Panel opening and closing dimension Indoor unit Unit surface figure Service space 400 or more Unit front figure 1000 or more 1 200 or more 1 It is necessary for the removal of the panel beyond 600mm 500 or more 710 Refrig piping gas in 2 refrig circuit system type P450 ø 19 05 braze type P560 ø 22 2 braze No 2 680 2 ø 32 knook out hole ø 32 knook out hole Air outlet Air inlet Power supply White...

Page 15: ...e service handbook about the switch operations CENTRAL CONTROL TRANSMISSION LINE CNRS2 Inverter controller box Function device liquid outlet temp detect at Sub cool coil Discharge pipe temp detect OA temp detect Pipe temp detect Hex outlet Choke coil Transmission Thermistor High pressure switch 4 way valve Electronic expansion valve SC coil Solenoid valve Heat exchanger capacity control Solenoid v...

Page 16: ... operations Address setting Function setting Maintenance setting Control circuit board TB3 Terminal Block TB7 Terminal Block TB1 Terminal Block ACNF Noise Filter M2 M1 M2 M1 shield shield CENTRAL CONTROL TRANSMISSION LINE INDOOR OUTDOOR TRANSMISSION LINE Power source 3N 380 400 415V 50 60Hz L3 N L1 L2 blue black white red blue N 1 9 2 1 9 1 5 6 10 9 14 13 10 14 13 9 6 5 1 2 black red red black 10 ...

Page 17: ...S B CN54 L3 TB5 SHIELD L2 L1 L4 FAN over current detection 51F Z1 ZNR2 52F Z3 51F 52F MF TH24 TH21 TH22 TH23 6 5 4 3 2 1 LEV SYMBOL NAME DSA1 Surge absorber LED display power supply F901 ZNR1 ZNR2 ZNR901 MF I B S B IFB TB2 TB5 TB15 TB21 TB22 TB23 F1 T LEV 52F 51F 33P1 RC L4 L3 L2 L1 Z3 Z1 X11 SWC I B SW14 I B SW12 I B SW11 I B SW9 SW4 I B SW3 I B SW2 I B SW1 I B Surge absorber board Switch outlet ...

Page 18: ...22 CN21 CN20 1 1 2 2 CN29 1 2 3 2 1 CN31 1 2 CN28 5 3 1 CN60 1 2 3 4 5 6 3 1 1 3 7 3 1 5 1 1 3 9 Z2 note2 33P2 T Z3 CN25 CN24 12 CN7V 1 2 3 4 5 6 7 2 1 X12 SW5 SWC SW12 2nd digit SW11 1st digit SW8 Address odd SW3 SW1 SW2 SW7 SW4 SW14 0 F E DCB A 9 0 9 8 7 6 5 4 3 2 1 9 1 2 3 4 5 6 7 8 0 8 7 6 5 4 3 2 1 No 2 FAN over current detection 51F Z1 ZNR2 Z2 52F Z3 TH24 2 TH21 2 TH22 2 TH23 2 51F 52F MF NA...

Page 19: ...efrigerant Circuit Diagram And Thermal Sensor PUHY P250YGM A 21S4a 21S4b COMP O S CJ1 CJ2 63HS 63LS 63H SV1 HEX F HEX B SV5b TH8 TH11 TH5 TH6 TH7 CP2 ST8 LEV1 SCC ST4 ST3 CP1 Drier ST7 ST6 ACC BV1 BV2 ST1 ST2 ...

Page 20: ...b TH6 CP2 CP1 TH11 TH12 COMP 2 Oil Tank COMP 1 O S O S CJ3 CJ1 63H2 63H1 63HS ST7 ST6 ST5 SV1 SV3 CV1 CV2 HEX2b B HEX1b F TH5 TH8 SCC CP3 TH7 ST9 Drier LEV1 ST8 SV5c SV5b HEX2a B HEX1a F ST2 ST13 ST12 ST11 ST10 CJ2 63LS BV2 ACC BV1 ST1 ...

Page 21: ...ation Amount of charged refrigerant at factory shipment Sample calculation Outdoor unit model Charged refrigerant amount kg 9 5 P250 22 0 P500 Outdoor unit L L H A Outdoor unit L H A Indoor unit Indoor unit Liquid pipe size Total length of the ø 15 88 pipes x 0 2 Liquid pipe size Total length of the ø 9 52 pipes x 0 06 m x 0 2 kg m m x 0 06 kg m Total capacity of connected indoor units Amount for ...

Page 22: ... cannot be con nected to the indoor units other than the PFD type indoor units 3 The PFD type indoor units cannot be connected to the ME remote controller 4 The address settings must be made on this system The automatic address setup cannot be made 5 The following functions cannot be selected on the PFD type indoor units 1 Switching between automatic power recovery Enabled Disabled Fixed to Enable...

Page 23: ...r within the range shown in the parenthesis Cable type The need for address settings and the range of address setting depend on the configuration of the sys tem Refer to Sample System Connection Symbol Unit or controller Main Sub Indoor unit MA remote controller Address setting range IC 01 50 Note 1 Address setting method Factory setting No address setting required 00 00 MA Outdoor unit OC Main 51...

Page 24: ...arge temperature sensor is supplied as standard specification 2 Power supply switch connector connection on the outdoor unit Factory setting The male power supply switch connector is connected to CN41 Grouping system Power supply switch connector connection Not connected Not grouped Grouped Required Grouped Not grouped Grouped Not grouped Grouped Not grouped Not required Leave the male connector o...

Page 25: ...minal block TB5 on the indoor unit IC Non polarized 2 core cable Only use shielded cables Shielded cable connection Connect the earth terminal of the OC and S terminal of the IC terminal block TB5 b Switch setting Address setting is required as follows Main Controller Sub Controller Settings to be made with the sub main switch IC IC OC 1 2 Notes 3 MA MA 51 100 01 50 01 50 00 00 Setting not require...

Page 26: ...and connect it to the female power supply switch connector CN40 on only one of the outdoor units Only use shielded cables Shielded cable connection To ground the shielded cable daisy chain the S terminals on the terminal block TB7 on each of the outdoor units Connect the S shielded terminal on the terminal block TB7 on the outdoor unit whose male connector on CN41 was disconnected and connected to...

Page 27: ...ers are connected to the system connect terminals 1 and 2 of the terminal block TB15 on the indoor unit IC to the terminal block on the MA remote controllers option Set the Main Sub switch on the connected MA remote controllers option to SUB See the installation manual for the MA remote controller for the setting method c Switch setting Address setting is required as follows Main Controller Sub Co...

Page 28: ...equired as follows Main Controller Sub Controller Settings to be made with the sub main switch IC IC OC 1 2 Notes 3 MA MA 51 100 01 50 01 50 00 00 Setting not required Sub Controller One indoor controller controller circuit board is equipped in the indoor unit 10HP and two indoor controllers controller circuit boards are equipped in the indoor unit 20HP Steps Unit or controller Main Sub Indoor uni...

Page 29: ...ge Level Dip SW1 9 OFF Output No 1 Operation Status Obtaining signals indicating operation status of indoor units in each refrigerant circuit Relay a contact output DC 30V or AC 100V 200V Standard Current 1A Minimum Current 1mA No 1 Error Status Obtaining signals indicating error status of indoor units in each refrigerant circuit No 2 Operation Status Obtaining signals indicating operation status ...

Page 30: ...current contact DC12V 1mA SW11 Relay contact output DC30V or less 1A AC220 240V 1A No 1 Operation Status Indicator Lamp L1 No 1 Error Status Indicator Lamp L2 Power supply for displays No 2 Operation Status Indicator Lamp L3 No 2 Error Status Indicator Lamp L4 Relay Permissible Electrical Current 10mA 1A XA XE Setting on the Indoor Unit Confirm the following setting when using external input 1 No ...

Page 31: ...ts may not operate 2 Do not bundle with high voltage AC220 240V wire since noise interference from such wire may cause the unit to malfunction 3 Do not bundle with minute voltage DC30V or below wire since noise interference from such wire may cause the unit to malfunction Caution 1 Wiring should be covered by insulation tube with supplementary insulation 2 Use relays or switches with IEC or equiva...

Page 32: ...t the predetermined conditions constant temperature constant humidity at the time the air exits the unit Close attention must be paid to the auto controlling system 2 Dust in the duct space between the free access top floor and the existing floor must be thoroughly removed before installing the unit 3 Since the existing floor is cooled by the unit it may produce dews on the ceiling of the room dow...

Page 33: ...ce earthquake proof anti vibration floor load anti vibration device noise control etc Calculating the Load Setting the Conditions for the Room Temperature humidity Condition Purpose Making decisions on the computer system Accommodates possible future expansion ensuring the acquisition route Operation schedule Back up system in case of breakdowns power outage water supply cut offs etc Air condition...

Page 34: ...e computer 3 Matching the Volume of Air Flow It is possible to use the fan on the computer to cool the room This controlling method requires a certain volume of cold air in proportion to the amount of heat produced by the device The inlet panel is located at the bottom of the unit and the exhaust pipe is located either on the ceiling front and back or on the side 4 Considering a Back up Air Condit...

Page 35: ...air conditioning system are set air conditioning capacity has to be determined by calculating the load 2 Unlike the outdoor air computer load remains constant throughout the year However it is possible that there are considerable fluctuations within a day This is due to the fact that depending on the time of the day there are changes in the number of computers that are turned on and that the diffe...

Page 36: ...6 8 kW Total Infiltration draft Number of people in the room Outside air 39 6 834 0 0117 5 persons 82 125m3 834 0 0117 0 39 kW 0 41 kW 1 22 kW 2 0 kW Total 26800 0 336 24 18 V 60 221m3 min Calculate the temperature difference by setting the outdoor temperature then calculate hourly loads The chart shows the result of a calculation supposing that the system reaches its highest load at 12 o clock Ou...

Page 37: ...ure with a built in controller suction temperature or discharge temperature control This unit is designed for high sensible heat specifications and it does not include a humidifier or a dehumidi fier Install such components as necessary 1 Bold lines in the diagram indicate refrigerant piping gas liquid This system consists of single refrigerant circuit 2 Indicates TB3 type transmission line used t...

Page 38: ...s The chart shows an approximate longevity of parts It is an estimation of the time when old parts may need to be replaced or repairs need to be made It does not mean that the parts must absolutely be replaced except for the fan belt Please note that the figures in the chart do not mean warranty periods 2 Notes The above chart shows a maintenance schedule for a unit that is used under the followin...

Page 39: ... or damage Clean Check for unusual noise Measure insulation resistance Free of unusual sound Insulation resistance over 1MΩ Replace if insulation resistance goes below 1MΩ Make sure the lamp comes on Comes on when the output is on Replace if the light does not come on when the power is on Perform an operation check using the operation data Adequately controls the air temperature Replace if malfunc...

Page 40: ......

Page 41: ...HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Issued in Mar 2006 MEE05K442 Printed in Japan New publication effective Mar 2006 Specifications subject to change without notice ...

Reviews: