9. The sewing machine will coast to a stop when the power is turned OFF or a power failure occurs during sewing machine operation.
10. Always align the connector shape and direction, and securely insert the connector.
11. If the position detector's connector dislocates, or the sewing machine is completely locked, the motor will be turned OFF automatically for a
set time to prevent burning. (Note that the motor may not turn OFF if there is incomplete locking or an overload.) When the fault has been
recovered, turn the power OFF and ON once to resume normal operation. The same type of operation will take place if a detector fault or
disconnection occurs.
12
.
Use the machine away from strong noise sources such as high
frequency welders.
13. When connecting the external switch to an optional connector,
etc., keep the signal wire as short as possible. A long wire could
cause malfunctions.
Use a shielded wire for the signal wire when possible.
14. If the fuse blows, remove the cause, and replace the blown fuse with one having the same capacity.
(View from the front with cover removed)
(View from the front
with the cover and CPU removed)
Solenoid board located
on back of machine head
15
.
Attention when power supply is turned on again
Please make sure that turning on the power supply switch,
after the LED of the front panel on the controlbox is completely turned off.
(Please do not turn on the power supply again while displaying
the screen of the oepration panel.)
Noise
PLK-G2-PMD
XC-G2-2B-PLK
PLK-G2-CPU
PLK-G2-PMD
PLK-G2-PMM
8A fuse(one fuse)
2.5A fuse(two fuses)
20A fuse(two fuses)
20A fuse(two fuses)
15A fuse(one fuse)