11
3-1. SPECIFICATIONS
3
SPECIFICATIONS
Service Ref.
PLFY-P08NEMU-E
PLFY-P12NEMU-E
PLFY-P15NEMU-E
PLFY-P18NEMU-E
Power source
1-Phase 208–230 V, 60 HZ
Cooling capacity
(Nominal)
*1
*1
BTU/h
8,000
2.4
12,000
3.5
15,000
4.4
18,000
5.3
kW
Power input
kW
0.02
0.02
0.02
0.02
Current input
A
0.25
0.26
0.29
0.29
Heating capacity
(Nominal)
*2
*2
BTU/h
9,000
2.7
13,500
4.0
17,000
5.0
20,000
5.9
kW
Power input
kW
0.02
0.02
0.02
0.02
Current input
A
0.20
0.21
0.24
0.24
External finish
Galvanized steel sheet
External dimension H × W × D
in
10-3/16 × 33-3/32 × 33-3/32
258 × 840 × 840
10-3/16 × 33-3/32 × 33-3/32
258 × 840 × 840
10-3/16 × 33-3/32 × 33-3/32
258 × 840 × 840
10-3/16 × 33-3/32 × 33-3/32
258 × 840 × 840
mm
Net weight
lb [kg]
42 [19]
42 [19]
42 [19]
42 [19]
Grille
Model
PLP-40EAU
PLP-40EAU
PLP-40EAU
PLP-40EAU
External finish
MUNSELL (6.4Y 8.9/0.4)
Dimension
H × W × D
in
1-9/16 × 37-3/8 × 37-3/8
40 × 950 × 950
1-9/16 × 37-3/8 × 37-3/8
40 × 950 × 950
1-9/16 × 37-3/8 × 37-3/8
40 × 950 × 950
1-9/16 × 37-3/8 × 37-3/8
40 × 950 × 950
mm
Net weight
lb [kg]
11 [5]
11 [5]
11 [5]
11 [5]
Heat exchanger
Cross fin
FAN
Type × Quantity
Turbo fan × 1
Turbo fan × 1
Turbo fan × 1
Turbo fan × 1
External static
press.
in. WG
0.000 (208 V)
0
0.000 (208 V)
0
0.000 (208 V)
0
0.000 (208 V)
0
Pa
in. WG
0.000 (230 V)
0
0.000 (230 V)
0
0.000 (230 V)
0
0.000 (230 V)
0
Pa
Motor type
DC motor
Motor output
kW
0.050
0.050
0.050
0.050
Driving mechanism
Direct drive
Airflow rate
(Low-Mid2-
Mid1-High)
cfm
424-459-494-530
12.0-13.0-14.0-15.0
200-217-233-250
459-494-530-565
13.0-14.0-15.0-16.0
217-233-250-267
459-494-530-600
13.0-14.0-15.0-17.0
217-233-250-283
459-494-565-636
13.0-14.0-16.0-18.0
217-233-267-300
m³/min
L/s
Sound pressure level
(Low-Mid2-Mid1-High)
(measure in anechoic room)
dB <A>
27-29-30-31 (208–230 V)
―
―
27-29-30-31 (208–230 V)
―
―
28-29-30-31 (208–230 V)
―
―
28-30-31-32 (208–230 V)
―
―
dB <A>
dB <A>
Insulation material
PS
Air filter
PP honeycomb (long life filter, anti-bacterial type)
Protection device
Fuse
Refrigerant control device
LEV
Connectable outdoor unit
R410, CITY MULTI
Diameter of refrigerant
pipe (O.D.)
Liquid
in [mm]
1/4 [6.35] Flare
1/4 [6.35] Flare
1/4 [6.35] Flare
1/4 [6.35] Flare
Gas
in [mm]
1/2 [12.7] Flare
1/2 [12.7] Flare
1/2 [12.7] Flare
1/2 [12.7] Flare
Field drain pipe size
in [mm]
O.D 1-1/4 [32]
O.D 1-1/4 [32]
O.D 1-1/4 [32]
O.D 1-1/4 [32]
Standard attachment
Document, accessory
Installation Manual, Instruction Book
Optional parts
Air outlet shutter plate
PAC-SJ37SP-E
PAC-SJ37SP-E
PAC-SJ37SP-E
PAC-SJ37SP-E
High efficiency filter element
PAC-SH59KF-E
PAC-SH59KF-E
PAC-SH59KF-E
PAC-SH59KF-E
Multi-function casement
PAC-SJ41TM-E
PAC-SJ41TM-E
PAC-SJ41TM-E
PAC-SJ41TM-E
Remarks
Installation
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items
shall be referred to the Installation Manual.
*1
Nominal cooling conditions
*2
Nominal heating conditions
Indoor: 80°F D.B./67°F W.B 70°F D.B.
[26.7°C D.B./19.4°C W.B ] [21.1°C D.B.]
Outdoor: 95°F D.B. 47°F D.B./43°F W.B
[35°C D.B.] [8.3°C D.B./6.1°C W.B]
Pipe length: 25 ft [7.6m] 25 ft [7.6m]
Level difference: 0 ft [0 m] 0 ft [0 m]
Note: Due to continuing improvement, above specification may be subject to change without notice.
Unit converter
kcal/h = kW × 860
BTU/h = kW × 3,412
cfm = m3/min x 35.31
lb = kg/0.4536
Above specification data is
subject to rounding variation
.
OCH611D