13
12
13
OCH715
3
SPECIFICATION
3-1. SPECIFICATIONS
Model
PKFY-P04NLMU-E
PKFY-P06NLMU-E
PKFY-P08NLMU-E
Power source
1-phase 208-230 V 60 Hz
Cooling capacity *1
(Nominal) *1
kW
1.1
1.8
2.3
BTU/h
4000
6000
8000
Power input
kW
0.02
0.02
0.03
Current input A
0.20
0.20
0.25
Heating capacity *2
(Nominal) *2
kW
1.3
2.0
2.6
BTU/h
4500
6700
9000
Power input
kW
0.01
0.01
0.02
Current input A
0.15
0.15
0.20
External finish(Munsell No.)
Plastic (0.7PB 9.2/0.4)
External dimension H x W x D
inch
11-25/32 x 30-7/16 x 9-11/32
mm
299 × 773 × 237
Net weight
lb (kg)
23.6 (10.7)
24.5(11.1)
Heat exchanger
Cross fin (Aluminum fin and copper tube)
Fan
Type x Quantity
Line flow fan x 1
External
static press
Pa
(mmH2O)
0 (0)
Motor type
DC motor
Motor output kW
0.03
Driving mechanism
Direct driven
Airflow rate
(Low-Mid2
-Mid1-High)
m
3
/min
3.3-3.5-3.8-4.2
4.0-4.4-4.9-5.4
4.0-4.6-5.4-6.7
L/s
55-58-63-70
67-73-82-90
67-77-90-112
cfm
117-124-134-148
141-155-173-191
141-162-191-237
Noise level
(Low-Mid2-Mid1-High)
(measured in anechoic room)
dB <A>
22-24-26-28
22-26-29-31
22-27-31-35
Insulation material
Polyethylene sheet
Air filter
PP Honeycomb
Protection device
Fuse
Refrigerant control device
LEV
Connectable outdoor unit
R410A CITY MULTI
Diameter of
refrigerant pipe
Liquid
in
(mm)
{
1/4 (
{
6.35)
Gas
in
(mm)
{
1/2 (
{
12.7)
Field drain pipe size
in
(mm)
I.D. 5/8 (16)
Standard attachment
Installation Manual, Instruction Book
Optional parts
DRAIN PUMP KIT
PAC-SK01DM-E
Remark
Details on foundation work, duct work, insulation work, electrical wiring, power source
switch, and other items shall be referred to the Installation Manual.
Due to continuing improvement, above specifications may be subject to change without
notice.
Notes:
*
1.Nominal cooling conditions (subject to JIS B8615-1)
Indoor: 81°FD.B./66°FW.B. (27°CD.B./19°CW.B.), Outdoor: 95°FD.B. (35°CD.B.)
Pipe length: 24-9/16 ft (7.5 m), Level difference: 0 ft (0 m)
*
2.Nominal heating conditions (subject to JIS B8615-1)
Indoor: 68°FD.B. (20°CD.B.), Outdoor: 45°FD.B./43°FW.B. (7°CD.B./6°CW.B.)
Pipe length: 24-9/16 ft (7.5 m), Level difference: 0 ft (0 m)
Unit converter
kcal/h = kW × 860
Btu/h = kW × 3,412
cfm = m
3
/min × 35.31
lb = kg/0.4536
Note: Above specification
data is subject to
rounding variation.