7. Troubleshooting

Having trouble?

Here is the solution. (Unit is operating normally.)

Air conditioner does not heat or cool well.

 

Clean the filter. (Airflow is reduced when the filter is dirty or clogged.)

 

Check the temperature adjustment and adjust the set temperature.

 

Make sure that there is plenty of space around the outdoor unit. Is the 
indoor unit air inlet or outlet blocked?

 

Has a door or window been left open?

When heating operation starts, warm air does not blow from the indoor 
unit soon.

 

Warm air does not blow until the indoor unit has sufficiently warmed 
up.

During heat mode, the air conditioner stops before the set room 
temperature is reached.

 

When the outdoor temperature is low and the humidity is high, 
frost may form on the outdoor unit. If this occurs, the outdoor unit 
performs a defrosting operation. Normal operation should begin after 
approximately 10 minutes.

Airflow up/down direction changes during operation or airflow up/down 
direction cannot be set.

 

During cool mode, the vanes automatically move to the horizontal 
(down) position after 1 hour when the down (horizontal) airflow up/
down direction is selected. This is to prevent water from forming and 
dripping from the vanes.

 

During heat mode, the vanes automatically move to the horizontal 
airflow up/down direction when the airflow temperature is low or 
during defrosting mode.

When the airflow up/down direction is changed, the vanes always move 
up and down past the set position before finally stopping at the position.

  When the airflow up/down direction is changed, the vanes move to the 

set position after detecting the base position.

A flowing water sound or occasional hissing sound is heard.

  These sounds can be heard when refrigerant is flowing in the air 

conditioner or when the refrigerant flow is changing.

A cracking or creaking sound is heard.

  These sounds can be heard when parts rub against each due to 

expansion and contraction from temperature changes.

The room has an unpleasant odor.

  The indoor unit draws in air that contains gases produced from the 

walls, carpeting, and furniture as well as odors trapped in clothing, 
and then blows this air back into the room.

A white mist or vapor is emitted from the indoor unit.

  If the indoor temperature and the humidity are high, this condition may 

occur when operation starts.

  During defrosting mode, cool airflow may blow down and appear like a 

mist.

Water or vapor is emitted from the outdoor unit.

  During cool mode, water may form and drip from the cool pipes and 

joints.

  During heat mode, water may form and drip from the heat exchanger.

  During defrosting mode, water on the heat exchanger evaporates and 

water vapor may be emitted.

The operation indicator does not appear in the wired remote controller 
display. (*1)

  Turn on the power switch. “ ” will appear in the wired remote 

controller display.

” appears in the wired remote controller display. (*1)

  During central control, “

” appears in the wired remote controller 

display and air conditioner operation cannot be started or stopped 
using the wired remote controller.

When restarting the air conditioner soon after stopping it, it does not 
operate even though the ON/OFF button is pressed.

  Wait approximately three minutes.

  (Operation has stopped to protect the air conditioner.)

Air conditioner operates without the ON/OFF button being pressed. (*1)

  Is the on timer set?

  Press the ON/OFF button to stop operation.

  Is the air conditioner connected to a central wired remote controller?

  Consult the concerned people who control the air conditioner.

 Does “

” appear in the wired remote controller display?

  Consult the concerned people who control the air conditioner.

  Has the auto recovery feature from power failures been set?

  Press the ON/OFF button to stop operation.

Air conditioner stops without the ON/OFF button being pressed. (*1)

  Is the off timer set?

  Press the ON/OFF button to restart operation.

  Is the air conditioner connected to a central wired remote controller?

  Consult the concerned people who control the air conditioner.

 Does “

” appear in the wired remote controller display?

  Consult the concerned people who control the air conditioner.

Wired remote controller timer operation cannot be set. (*1)

  Are timer settings invalid?

  If the timer can be set, 

WEEKLY

SIMPLE

, or 

AUTO OFF

 appears in 

the wired remote controller display.

“PLEASE WAIT” appears in the wired remote controller display. (*1)

  The initial settings are being performed. Wait approximately 3 

minutes.

An error code appears in the remote controller display. 

  The protection devices have operated to protect the air conditioner.

  Do not attempt to repair this equipment by yourself.

  Turn off the power switch immediately and consult your dealer. Be 

sure to provide the dealer with the model name and information that 
appeared in the remote controller display.

Draining water or motor rotation sound is heard.

  When cooling operation stops, the drain pump operates and then 

stops. Wait approximately 3 minutes.

When dry mode starts, the set temperature changes.

  When Dry mode starts, the set temperature automatically changes to 

the optimum initial set temperature.

Summary of Contents for PKA-A KA4

Page 1: ... UTILISATION Pour une utilisation correcte sans risques veuillez lire le manuel d utilisation en entier avant de vous servir du climatiseur FOR USER POUR L UTILISATEUR English Français MANUAL DE INSTRUCCIONES Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado para garantizar un uso seguro y correcto PARA EL USUARIO Español ...

Page 2: ... contact your dealer Warning For appliances not accessible to the general public The unit must not be installed by the user Ask the dealer or an authorized company to install the unit If the unit is installed improperly water leakage electric shock or fire may result Do not stand on or place any items on the unit Do not splash water over the unit and do not touch the unit with wet hands An electri...

Page 3: ...e controller has been received Signals can be received up to approximately 7 meters 275 19 32 inch in a direct line from the indoor unit in an area 45 to the left and right of the unit However illumination such as fluorescent lights and strong light can affect the ability of the indoor unit to receive signals If the operation lamp near the receiver on the indoor unit is flashing the unit needs to ...

Page 4: ...roller display 1 When the unit is in STAND BY or DEFROST states 2 When the temperature of the heat exchanger is low in the heat mode e g immediately after heat operation starts 3 In HEAT mode when room temperature is higher than the temperature setting 4 When the unit is in DRY mode 3 4 Airflow up down direction setting Note During swing operation the directional indication on the screen does not ...

Page 5: ...quipped with filters to remove the dust of sucked in air Clean the filters using the methods shown in the following sketches 6 Care and Cleaning Combination Cooling and Heating Models Cooling Only Models Operation Monitor Display GREEN ORANGE STOP The display will appear orange for 5 seconds following the switch operation as indicated at the left and then it will return to the regular display COOL...

Page 6: ...ing cool mode water may form and drip from the cool pipes and joints During heat mode water may form and drip from the heat exchanger During defrosting mode water on the heat exchanger evaporates and water vapor may be emitted The operation indicator does not appear in the wired remote controller display 1 Turn on the power switch will appear in the wired remote controller display appears in the w...

Page 7: ...hing appears even after the batteries are replaced make sure that the batteries are installed in the correct directions The operation lamp near the receiver for the IR wireless remote controller on the indoor unit is flashing 2 The self diagnosis function has operated to protect the air conditioner Do not attempt to repair this equipment by yourself Turn off the power switch immediately and consul...

Page 8: ...uent pas avec le climatiseur Si le gaz de réfrigérant fuit arrêter le fonctionnement du climatiseur aérer convenablement la pièce et prendre contact avec le revendeur Avertissement Pour les appareils non disponibles au grand public Cet appareil ne doit pas être installé par l utilisateur Demander au revendeur ou à une société agréée de l installer Si l appareil n est pas correctement installé il p...

Page 9: ...oite à partir de l appareil intérieur et dans une zone de 45 vers la gauche ou la droite de l appareil Cependant une lumière vive ou fluorescente peut gêner la réception de signaux de l appareil intérieur Si le témoin de fonctionnement situé près du récepteur de l appareil intérieur clignote ceci signifie que l appareil doit être inspecté Consultez votre revendeur pour connaître les modalités d en...

Page 10: ...ent de l opération de chauffage 3 En mode CHAUFFAGE quand la température ambiante dans la pièce est supérieure à la température réglée 4 Quand l unité est en mode SEC 3 4 Réglage de la direction du flux d air vertical Remarque Pendant l oscillation l indication directionnelle à l écran ne change pas en synchronisation avec les ailettes de l unité Les directions disponibles dépendent du type d unit...

Page 11: ...rrêter l appareil et couper l alimentation Les appareils intérieurs sont équipés de filtres servant à extraire les poussières de l air aspiré Nettoyer les filtres selon les méthodes illustrées ci après 6 Entretien et nettoyage Modèles de chauffage et de refroidissement Modèles de refroidissement seulement Moniteur VERT ORANGE ARRÊT L affichage est orange pendant 5 secondes après le basculement com...

Page 12: ...l apparence de la buée De l eau ou de la vapeur sort de l appareil extérieur En mode de refroidissement de l eau peut se former et suinter des tuyaux et des raccords froids En mode de chauffage de l eau peut se former et suinter de l échangeur thermique En mode de dégivrage l eau présent sur l échangeur thermique s évapore provoquant ainsi une émission de vapeur d eau Le témoin de fonctionnement n...

Page 13: ...rieur aux caractéristiques sonores mesurées dans une pièce sans écho Pièces présentant une absorption phonique élevée Pièces présentant une absorption phonique normale Pièces présentant une absorption phonique faible Exemples de pièce Studio de radiodiffusion salle de musique etc Salle de réception entrée d hôtel etc Bureau chambre d hôtel Niveaux sonores 3 à 7 dB 6 à 10 dB 9 à 13 dB Rien n appara...

Page 14: ...queños deben estar vigilados por personas adultas para impedir que jueguen con el equipo de aire acondicionado Si se producen fugas de gas refrigerante pare la unidad ventile bien la habitación y avise a su proveedor Atención Para aparatos no accesibles para el público en general La unidad no debe ser instalada por el usuario Pida a su distribuidor o a una empresa debidamente autorizada que se lo ...

Page 15: ...imo de 7 metros 275 19 32 inch en línea recta en un rango de 45 a derecha e izquierda de la unidad Sin embargo ciertos sistemas de iluminación con fluorescentes o luces fuertes pueden afectar a la capacidad de recepción de señal de la unidad interior Si la luz de funcionamiento situada cerca del receptor de la unidad interior parpadea será necesario inspeccionar la unidad Consulte a su representan...

Page 16: ... HEAT cuando la temperatura ambiente de la habitación es superior al valor de configuración de la temperatura 4 Cuando la unidad esté en modo DRY 3 4 Ajuste de la dirección del flujo de aire Nota Durante la operación de oscilación la indicación de dirección en la pantalla no cambia al mismo tiempo que los deflectores direccionales de la unidad Las direcciones disponibles dependen del tipo de unida...

Page 17: ...do Limpie el filtro usando los métodos indicados en las ilustraciones siguientes 6 Mantenimiento y limpieza Modelos con combinación de refrigeración y calefacción Modelos con sólo refrigeración Pantalla del monitor de funcionamiento VERDE NARANJA STOP La pantalla aparecerá en naranja durante 5 segundos después de accionar el interruptor como se indica a la izquierda y luego volverá a aparecer la p...

Page 18: ...ante el modo de frío puede acumularse agua y gotear de las tuberías y juntas de refrigeración Durante el modo de calor puede acumularse agua y gotear del intercambiador de calor Durante el modo de descongelación el agua del intercambiador de calor se evapora por lo que se emite vapor de agua El indicador de funcionamiento no aparece en la pantalla del controlador remoto cableado 1 Encienda el equi...

Page 19: ...rarrojos esté cerca 2 Las pilas apenas tienen carga Sustitúyalas y pulse el botón Reset Restablecimiento Si la situación no cambia al sustituir las pilas asegúrese de que están colocadas con la polaridad correcta La luz de funcionamiento cerca del receptor del controlador remoto inalámbrico por infrarrojos de la unidad interior está parpadeando 2 La función de autodiagnóstico se ha activado para p...

Page 20: ...e be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Printed in Thailand RG79D675H01 ...

Reviews: