Rating Conditions (ISO T1)
Service Ref.
Item
Btu/h
W
kW
kW
A
A
kW
K
/min(CFM)
Pa(mmAq)
dB
mm(in.)
mm(in.)
mm(in.)
mm(in.)
kg(lbs)
A
A
kW
W
kW
K
/min(CFM)
dB
dB
mm(in.)
mm(in.)
mm(in.)
kg(lbs)
kg(lbs)
L
mm(in.)
mm(in.)
Function
Capacity
Total input
Service Ref.
Power supply
Input
Running current
Starting current
External finish
Heat exchanger
Fan
Fan(drive) x No.
Fan motor output
Airflow(Lo-Hi)
External static pressure
Operation control & Thermostat
Noise level(Lo-Hi)
Unit drain pipe I.D.
Dimensions
Weight
Service Ref.
Power supply
Running current
Starting current
External finish
Refrigerant control
Compressor
Model
Motor output
Starter type
Protection devices
Crankcase heater
Heat exchanger
Fan
Fan(drive) x No.
Fan motor output
Airflow
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Charge
Oil (Model)
Pipe size O.D.
Connection method
Between the indoor &
outdoor unit
PCA-P5HA
Cooling
44,400
13,000
4.90
0.26
1.19
2.38
6.85
Heating
54,600
16,000
4,98
0.26
1.19
2.38
7.07
W
D
H
Cooling
Heating
W
D
H
Liquid
Gas
Indoor side
Outdoor side
Height difference
Piping length
PCA-P5HA
Single phase, 50Hz, 220-230-240V
Stainless steel
Plate fin coil
Sirocco (direct) x 4
0.08+0.08
30-38 <1,060-1,350>
0 (direct blow)
Remote controller & built-in
44-50
26(1)
1,520(59-7/8)
650(25-5/8)
280(11)
56(124)
PUH-P5YGAA
1
.UK
3 phase, 50Hz, 380-400-415V (4wires)
65.5
Munsell 5Y 7/1
Linear Expansion Valve
Hermetic
ZR61KCW-TFD
3.5
Line start
Anti-phase protector, Internal thermostat, HP switch,Thermal relay, Discharge thermo
38
Plate fin coil
Propeller (direct) x 2
0.070+0.070
95(3,360)
Reverse cycle
55
56
1,050(41-5/16)
330+20(13+3/4)
1,260(49-5/8)
112(247)
R407C
4.6(10.1)
1.690 (Ester) 3MAW-POE
9.52(3/8)
19.05(3/4)
Flared
Flared
Max. 50m
Max. 50m
Notes1. Rating Conditions (ISO T1)
Cooling : Indoor : D.B. 27˚C(80˚F), W.B. 19˚C (66˚F) Outdoor : D.B. 35˚C(95˚F), W.B. 24˚C (75˚F)
Heating : Indoor : D.B. 20˚C(68˚F)
Outdoor : D.B. 7˚C(45˚F), W.B. 6˚C (43˚F)
Refrigerant piping length (one way) : 5m (16ft)
2. Guaranteed operating range
3. Above data based on indicated voltage
Indoor Unit
Single phase 230V 50Hz
Outdoor Unit 3 phase 400V 50Hz
Upper limit
Lower limit
Upper limit
Lower limit
Indoor
D.B. 35˚C, W.B. 22.5˚C
D.B. 19˚C, W.B. 15˚C
D.B. 28˚C
D.B. 17˚C
Outdoor
D.B. 46˚C
D.B. -5˚C
D.B. 24˚C, W.B. 18˚C
D.B. -11˚C, W.B. -12˚C
Cooling
Heating
OUTDOOR UNIT
INDOOR UNIT
REFRIGERANT PIPING