REFRIGERANT SYSTEM DIAGRAM
Unit : mm
<4-way valve solenoid coil>
Heating : ON
Cooling : OFF
PCA-P3HA / PUH-3VGAA
1
.UK, PUH-3YGAA
1
.UK
Indoor unit
Outdoor unit
Thermistor
(TH1)
Strainer
(#50)
Flared
connection
Flexible tube
Service
port
Accumulator
Ball valve
Compressor
Refrigerant pipe
15.88
A
(
{
5/8")
(with heat insulator)
Refrigerant pipe
9.52
A
(
{
3/8")
(with heat insulator)
Stop valve
(with service port)
4-way valve
Service
port
High pressure
protect switch
Outdoor heat exchanger
Thermistor
(TH3)
Distributor
with
strainer
Thermistor
(TH6)
Distributor
with
strainer
Indoor coil
thermistor
(TH2)
Thermistor
(TH5)
Muffler
Thermistor(TH4)
Linear expansion valve
Refrigerant flow in cooling
Refrigerant flow in heating
(#50)
Strainer
(#100)
Strainer
(#100)
Strainer
Indoor unit
Outdoor unit
Thermistor
(TH2)
Flexible tube
Service
port
Accumulator
Compressor
Refrigerant pipe
19.05
A
(
{
3/4")
(with heat insulator)
Refrigerant pipe
9.52
A
(
{
3/8")
(with heat insulator)
Stop valve
(with service port)
4-way valve
Service
port
High pressure
protect switch
Thermistor
(TH3)
Capillary tube
(O.D.4.0
✕
I.D.3.0-L200)
✕
2pcs
Distributor
with
strainer
Flared
connection
Drier
Liner expansion valve
Bypass
valve
Thermistor
(TH5)
Thermistor
(TH1)
Muffler
Thermistor
(TH4)
Thermistor
(TH6)
Distributor
with
strainer
Capillary
tube
w
1
Refrigerant flow in cooling
Refrigerant flow in heating
w
1 : O.D.4.0
✕
I.D.2.0-L400(PUH-P5YGAA
1
.UK)
O.D.4.0
✕
I.D.3.0-L450(PUH-P6YGAA
1
.UK)
Ball valve
(#50)
Strainer
Strainer
(#100)
Strainer
(#100)
Strainer
(#50)
Strainer
(#50)
Indoor unit
Outdoor unit
Thermistor
(TH1)
Flared
connection
Flexible tube
Service
port
Accumulator
Compressor
Refrigerant pipe
15.88
A
(
{
5/8")
(with heat insulator)
Refrigerant pipe
9.52
A
(
{
3/8")
(with heat insulator)
Stop valve
(with service port)
Service
port
High pressure
protect switch
Outdoor heat exchanger
Thermistor
(TH3)
Distributor
with
strainer
Thermistor
(TH6)
Distributor
with
strainer
Indoor coil
thermistor
(TH2)
Thermistor
(TH5)
Thermistor(TH4)
Linear expansion valve
Refrigerant flow in cooling
Ball valve
(#50)
Strainer
(#100)
Strainer
(#100)
Strainer
Strainer
(#50)
PCA-P5HA / PUH-5YGAA
1
.UK
PCA-P3HA / PU-3VGAA
1
.UK, PU-3YGAA
1
.UK
Indoor unit
Outdoor unit
Thermistor
(TH2)
Flexible tube
Service
port
Accumulator
Compressor
Refrigerant pipe
19.05
A
(
{
3/4")
(with heat insulator)
Refrigerant pipe
9.52
A
(
{
3/8")
(with heat insulator)
Service
port
High pressure
protect switch
Thermistor
(TH3)
Capillary tube
(O.D.4.0
✕
I.D.3.0-L200)
✕
2pcs
Distributor
with
strainer
Flared
connection
Drier
Thermistor
(TH5)
Thermistor
(TH1)
Thermistor
(TH4)
Thermistor
(TH6)
Distributor
with
strainer
Refrigerant flow in cooling
Stop valve
(with service port)
Liner expansion valve
Ball valve
(#50)
Strainer
Strainer
(#100)
Strainer
(#100)
(#50)
Strainer
Strainer
(#50)
PCA-P5HA / PU-5YGAA
1
.UK