background image

3

Independent

system

(1) Same settings

K    

remote controller.

K $8

boards and the wire-
less remote controller 
are set to the same 
pair number.

K G  

the receiving range of 
the wireless remote 
controller or have
the operator move 
the wireless remote 
controller to operate 
each unit.

(2) Separate settings

K +   

remote controller.

K $8

and wireless remote 
controllers are set to 
different pair numbers 
for each unit.

Simultaneous 

twin/triple/
quadruple 

system

K  

regardless of which 
indoor unit receives
the signals.

Example of triple system

Fig. 4-1

Fig. 4-2

A

A

D

E

C

B

7

8

1

4

2

3

6

5

F

9

4.1. Switching to the initial setting mode

1. Press the 

button 

1

to stop the air conditioner.

K G 

button

8

 to disable the timer. (

F

disappears.)

2. Press the 

 button

2

.

K   k!

A

!;!z&)=

K $  button 

4

 to change the function No.

{!8 k!)|  

 button 

3

.

K '  !;!z&}=

4.2. Changing the temperature unit 

A

[Factory setting:°C] (Fig. 4-2)

Press the 

 button 

5

.

K +

 button

5

 is pressed, the setting switches between   and  .

  8!

   !

4.3. Changing the time display 

B

[Factory setting: 12-hour format]

Press the 

 button

6

.

K + 

 button

6

 is pressed, the setting switches between 

 and 

.

 )}& !
 }z& !

4.4. Changing the AUTO mode 

C

[Factory setting: Single set point]

Press the 

 button 

7

.

K +

button 

7

is pressed, the setting switches between   and  .

@V     ;'=!

@V  !

4.5. Changing the pair No. 

D

[Factory setting: 0]

Press the 

button 

4

.

K ' 

D

 to "0"–"3".

4.6. Changing the backlight setting 

E

[Factory setting: ON]

Press the

button

9

.

K + 

button

9

 is pressed, the setting switches between 

and 

.

  !

  !

4.7. Completing the settings

Press the

button 

3

.

K k!

A

! (Fig. 4-1)

 Press 

the

 button 

2

.

K The remote controller exits the initial setting mode. (The air conditioner operation is stopped.)

The  following settings can be made in the initial 

setting mode.

Item

Setting

Temperature unit

ºC/ºF

Time display

12-hour format/

24-hour format

AUTO mode

Single set point/

Dual set point

Pair No.

0–3

On/Off

Indoor unit setting

Slim air conditioner

Multi air conditioner

Pair No. of wireless 

remote controller

Indoor PC board jumper wire

(J41 and J42 settings)

Indoor PC board SW22 settings

SW22-3

SW22-4

0

Do not cut

ON

ON

1

Cut only J41

OFF

ON

2

Cut only J42

ON

OFF

3

Cut both J41 and J42

OFF

OFF

Outdoor unit

Outdoor unit

Indoor 

unit

Indoor 

unit

Indoor 

unit

Indoor 

unit

Indoor 

unit

Indoor 

unit

Indoor 

unit

Indoor 

unit

Pair No.0

Pair No.0

Pair No.0

Outdoor unit

Outdoor unit

Pair No.1

Pair No.1

Pair No.0

Pair No.0

Outdoor unit

Outdoor unit

Pair No.2

Pair No.2

Pair No.0

Outdoor unit

Outdoor unit

Pair No.3

Pair No.3

Pair No.0

Wireless remote controller operation unit

Wireless remote controller operation unit

Wireless remote controller operation unit

Wireless
remote 
controller 
receiver

Wireless
remote 
controller 
receiver

Wireless 
remote
controller 
receiver

Wireless
remote 
controller 
receiver

Wireless
remote 
controller 
receiver

Wireless 
remote
controller 
receiver

Wireless 
remote
controller 
receiver

Wireless 
remote
controller 
receiver

4 Initial Setting

Outdoor unit

Indoor 

unit

Indoor 

unit

Indoor 

unit

Pair No.0

Pair No.0

Pair No.0

Pair No.0

Wireless 
remote
controller 
receiver

Wireless 
remote
controller 
receiver

Wireless
remote
controller 
receiver

Setting example (when using slim air conditioners)

Summary of Contents for PAR-SL100A-E

Page 1: ...ses accumulated around the body of PAR SL100A E may cause an explosion Do not use in any special environment Using in any place exposed to oil including machine oil steam and sulfuric component parts Do not wash with water 4 Do not install in any place at a temperature of more than 40 C 104 F or less than 0 C 32 F or exposed to direct sunlight Ensure that installation work is done correctly follow...

Page 2: ... system i e inverter light is installed signal interference may occur Maximum signal receiving distance is approximately 7 meters Approx 22 feet Signal receiving angle is approximately 45 degrees to the right and the left from the center Install the unit at least 1 meter Approx 3 feet away from the TV or radio If the unit is installed too close to these appliances signal interference picture disto...

Page 3: ...s the button 3 K k A Fig 4 1 Press the button 2 K The remote controller exits the initial setting mode The air conditioner operation is stopped The following settings can be made in the initial setting mode Item Setting Temperature unit ºC ºF Time display 12 hour format 24 hour format AUTO mode Single set point Dual set point Pair No 0 3 On Off Indoor unit setting Slim air conditioner Multi air co...

Page 4: ... 02 2 speeds 03 1 speed none 04 If the setting is incorrect press the button 2 and repeat the procedure from step 1 3 Airflow direction setting Fig 5 2 The factory setting is With vane swing Setting number 01 1 Press the button 5 K D 2 Press the button 1 to select the setting number A Z D Setting No A With auto vane Without auto vane With vane swing With vane swing 01 With vane no swing With vane ...

Page 5: ... B Output pattern A OPERATION INDICATOR pattern Beep Beep Beep Beep Beep Beep Beep Off Approx 2 5 sec On 0 5 sec On 0 5 sec On 0 5 sec On 0 5 sec Off Approx 2 5 sec On 0 5 sec On 0 5 sec Repeated k k nth 1st 2nd 3rd 1st 2nd starts Start signal received Beeper sounds Output pattern C OPERATION INDICATOR pattern Beep Beep Beep Beep Beep Beep Beep Off Approx 2 5 sec 2 times 0 3 sec 2 2 times 0 3 sec ...

Page 6: ... outdoor unit thermistors 4 UF 8 5 U2 z 8 6 U1 Ud V 7 U5 8 U8 Outdoor unit fan protection stop 9 U6 Compressor overcurrent interruption Abnormal of power module 10 U7 Abnormality of super heat due to low discharge temperature 11 U9 UH Abnormality such as overvoltage or voltage shortage and abnormal synchro nous signal to main circuit Current sensor error 12 13 14 Others Other errors Refer to the t...

Page 7: ...he indoor unit installation manual for details Mode Settings Mode no Setting no Initial setting Setting Power failure automatic recovery Not available 01 1 Select unit number 00 Available 2 Indoor temperature detecting Indoor unit operating average 02 1 Set by indoor unit s remote controller 2 Remote controller s internal sensor 3 LOSSNAY connectivity Not Supported 03 1 2 Supported indoor unit is ...

Page 8: ...mber Fig 6 3 K While pointing the wireless remote controller toward the receiver press the button 4 V GVk Gk4G8 V cate the current setting number for the selected mode number 8 X G beep beep 0 4 0 4 0 4 sec If this occurs press the button 5 and then set the mode number again while the If the signal was not received correctly the beeper will not sound or it will beep twice If this occurs press the ...

Reviews: