background image

3

PAR-F27MEA

ON/OFF

˚C

˚C

FILTER

CHECK TEST

TEMP.

TIMER SET

CLOCK

ON

OFF

1

1

4

2

3

2

3

1

7

6

5

1

7

5

6

(1) On/off and operation mode selection and room temperature adjustment

When starting operation

Press the [ON/OFF] button 

1

.

• The ON lamp 

1

 and display light.

NOTE

The restarting operation contents are shown below.

When you want to change the set temperature

<When you want to lower the room temperature>

Press the [TEMP. (

)] button 

3

.

<When you want to raise the room temperature>

Press the [TEMP. (

)] button 

3

.

• The set temperature changes 1

°

C each time the button is pressed.

The set temperature is displayed at 

3

.

• The following specified temperatures can be set:

Room temperature display

During operation, the intake temperature is displayed at 

4

.

- The display range is 8 to 39

°

C. When this range is exceeded, the

room temperature display flashes at 8

°

C or 39

°

C.

- When multiple indoor units are controlled, the contents of the master

indoor unit are displayed on the remote controller.

- The room temperature sensor position can be selected from “INDOOR

UNIT” and “REMOTE CONTROLLER”.
The initial setting is “INDOOR UNIT”. When you want to change the
room temperature sensor position to “REMOTE CONTROLLER”, con-
sult your dealer.

- When “no room temperature display” was selected by remote control-

ler function selection, the room temperature is not displayed.

NOTES

Cool/dry

operation

Heat operation

Auto operation

Fan

19(14) to 30

°

C

17 to 28

°

C

19 to 28

°

C

The auto and heating functions may not be installed, depending on the
outdoor unit model.

NOTE

Remote controller settings

When stopping operation

Press the [ON/OFF] button 

1

.

• The ON lamp 

1

 and display go off.

When selecting the operation mode

Press the [Mode selection] button 

2

 while the air conditioner is oper-

ating.
• The setting is switched each time the button is pressed.

The operation mode is displayed at 

2

.

Operation

mode

Horizontal

outlet

Temperature

setting

Wind speed

Operation

mode

Last set wind speed

Last set temperature

Last operation mode

Last setting

Horizontal

outlet

Cannot be set.

3

How to Operate

Airflow

Summary of Contents for PAR-F27MEA

Page 1: ... may cause an electric shock or a malfunction Do not use the controller for special applications This product is designed for use with the CITY MULTI CONTROL SYSTEM Do not use the system for other air condition management operation or appli cations It may cause malfunctions Do not apply insecticide or flammable sprays to the controller Do not place flammable spray near the controller and make sure...

Page 2: ...VAILABLE display When the button of a function that is not installed at the indoor unit was pressed this display flashes simultaneously with the corresponding function display Operation mode Displays the operation mode Set temperature display Displays the set temperature For description purposes all the displays are assumed to be on Set effective for 1 hr display Displayed when low downward is sel...

Page 3: ... unit are displayed on the remote controller The room temperature sensor position can be selected from INDOOR UNIT and REMOTE CONTROLLER The initial setting is INDOOR UNIT When you want to change the room temperature sensor position to REMOTE CONTROLLER con sult your dealer When no room temperature display was selected by remote control ler function selection the room temperature is not displayed ...

Page 4: ...ing three setting methods ON timer operation Timer only starts the air conditioner OFF timer operation Timer only stops the air conditioner ON OFF timer operation Timer both starts and stops the air conditioner 2 Daily timer mode Operation of this mode is the same as that of the 1 day timer mode However timer operation can be set to the same time each day in accordance with the set ON OFF timer ti...

Page 5: ...display Timer setting display example 1 day timer mode REMAINDER CLOCK ON OFF When performing OFF timer operation 1 day timer mode daily timer mode Press the Time selection button 1 and check Current time CLOCK and set the display to Ending time OFF Set the OFF time by pressing the Time selection or button 2 Set the ON time to display Press the Timer selection button 3 and set the display to 1 day...

Page 6: ...ODE flashes ON lamp remains a steady light The air conditioner continues to operate but there is the possibility of trouble occurring Jot down the error code and consult your dealer When both the ON lamp and ERROR CODE flash trouble oc curred in the air conditioner and the air conditioner stops Jot down the unit number and error code and turn off the air condi tioner power and consult your dealer ...

Page 7: ...er is received from the outdoor unit over the indoor outdoor unit M NET transmission line 0 5 W Temperature 0 to 40 C humidity 30 to 90 RH No condensation PS ROOM TEMPERATURE DISPLAY SELECTION MODE When you want to change room temperature display no display 88 C flashes at the room temperature display and ON or OFF lights Each time the Time selection or button 4 is pressed in this state the ON and...

Reviews: